Evaluating large language model-generated brain MRI protocols: performance of GPT4o, o3-mini, DeepSeek-R1 and Qwen2.5-72B

Su Hwan Kim, Severin Schramm, Lena Schmitzer, Kerem Serguen, Sebastian Ziegelmayer, Felix Busch, Alexander Komenda, Marcus R. Makowski, Lisa C. Adams, Keno K. Bressem, Claus Zimmer, Jan S. Kirschke, Benedikt Wiestler, Dennis M. Hedderich, Tom Finck, Jannis BoddenEuropean 2025

Abstract

Purpose: To evaluate the potential of LLMs to generate sequence-level brain MRI protocols.

Methods: A dataset of 150 brain MRI cases was derived from imaging request forms. For each case, a reference MRI protocol was established by two board-certified neuroradiologists. GPT-4o, o3-mini, DeepSeek-R1, and Qwen-2.5-72B were employed to generate protocols under two conditions: 1) base (no external info) and 2) enhanced (with in-context learning of local protocols). Two radiology residents independently protocoled a subsample of 50 cases. Performance was measured by an "accuracy index" (sum of redundant and missing sequences).

Results: o3-mini (enhanced) showed superior performance (accuracy index: 1.94), followed by GPT-4o (2.23). All models improved significantly under the enhanced condition (p < 0.001), primarily by reducing redundant sequences. In the subsample, o3-mini (enhanced) achieved performance comparable to radiology residents.

Conclusion: LLMs, particularly o3-mini, show promising potential in automating brain MRI protocoling when augmented with in-context learning.

Introduction

In clinical radiology, "protocoling" is the process of reviewing a patient’s medical history to decide exactly which MRI sequences (e.g., FLAIR, T1, Diffusion-weighted imaging) are required. This task is a high-stakes balancing act: missing a critical sequence can delay diagnosis, while including redundant sequences wastes expensive scanner time. Currently, protocoling is a manual, time-consuming task that accounts for roughly 6% of a neuroradiologist's workday. This study investigates whether Large Language Models (LLMs) can handle this granular decision-making to alleviate the burden on clinicians.

Methods

The researchers compared four leading models: GPT-4o, o3-mini, DeepSeek-R1, and Qwen2.5-72B. The study utilized 150 brain MRI cases derived from real-world clinical data, balanced across five pathologies: vascular, neoplasia, inflammation, degenerative, and miscellaneous.

Overview of the study workflow comparing LLM-generated protocols under base and enhanced conditions against human benchmarks.

Each model was tested under two prompting conditions:

  • Base: A standard prompt asking the model to act as a neuroradiologist.
  • Enhanced: Using In-Context Learning (ICL), where the prompt was supplemented with 20 local standard protocols and detailed explanations of 27 different MRI sequences.

The primary metric was the Accuracy Index, defined as the sum of redundant sequences and missing sequences compared to a "ground truth" consensus established by two board-certified neuroradiologists. A human benchmark was established using a subsample of 50 cases protocoled by two radiology residents.

Key Results and Insights

The "Reasoning" Advantage and Context

The top-performing models (o3-mini and DeepSeek-R1) are "reasoning" models designed for chain-of-thought processing. However, the study found that context is king: every model showed highly significant improvements when moving from the Base to the Enhanced condition. ICL primarily helped models stop "over-prescribing" redundant sequences, reigning in the models' tendency to be overly cautious.

Performance Rankings

  • Top Performer: o3-mini (Enhanced) achieved the best accuracy index of 1.94.
  • Model Rankings (Enhanced): o3-mini (1.94) > GPT-4o (2.23) > DeepSeek-R1 (2.37) > Qwen2.5-72B (2.75).
  • Closing the Gap: The most striking finding was that o3-mini (Enhanced) achieved an accuracy index (1.92 in the subsample) comparable to human residents (1.80 and 1.44), suggesting LLMs are reaching baseline competency for junior specialists in this specific task.

Limitations and Future Work

While promising, the study was limited to a single institution's protocols. Future work must involve multi-center validation and the inclusion of technical parameters like slice thickness. Additionally, while cloud-based models performed best, open-weight models like DeepSeek-R1 offer a more viable path for privacy-preserving deployment on local hospital hardware. The authors suggest the next step is "agentic" LLM systems that can autonomously mine Electronic Medical Records (EMR) to generate protocols in a truly end-to-end automated workflow.

Summary updated

Abstract

QuestionBrain MRI protocoling is a time-consuming, non-interpretative task, exacerbating radiologist workload. Findingso3-mini demonstrated superior brain MRI protocoling performance. All models showed notable improvements when augmented with local standard protocols. Clinical relevanceMRI protocoling is a time-intensive, non-interpretative task that adds to radiologist workload; large language models offer potential for (semi-)automation of this process.
BibTeX
@inproceedings{kim2025evaluating,
  author = {Su Hwan Kim and Severin Schramm and Lena Schmitzer and Kerem Serguen and Sebastian Ziegelmayer and Felix Busch and Alexander Komenda and Marcus R. Makowski and Lisa C. Adams and Keno K. Bressem and Claus Zimmer and Jan S. Kirschke and Benedikt Wiestler and Dennis M. Hedderich and Tom Finck and Jannis Bodden},
  title = {{Evaluating large language model-generated brain MRI protocols: performance of GPT4o, o3-mini, DeepSeek-R1 and Qwen2.5-72B}},
  booktitle = {European},
  year = {2025},
  doi = {10.1007/s00330-025-11989-0},
}
Figure