Estimating MRI Image Quality via Image Reconstruction Uncertainty

Richard Shaw, Carole H. Sudre, Sebastien Ourselin, M. Jorge CardosoarXiv 2021 · arXiv

TL;DR

This paper introduces a Bayesian deep learning framework that uses image reconstruction uncertainty to automate MRI quality control. By distinguishing between "visual quality" (how an image looks to a human) and "algorithmic quality" (how usable it is for a specific task), the authors show that many scans typically discarded by experts are actually perfectly suitable for automated analysis.

What Problem Does This Paper Address?

Quality Control (QC) is a bottleneck in medical imaging. Currently, it relies heavily on expert radiologists manually inspecting scans for artifacts like motion blur or noise. This process is slow, expensive, and subjective.

More importantly, there is a mismatch between human and machine needs. A human might label a scan "unusable" because of a motion artifact at the edge of the field of view. However, if that artifact doesn't overlap with the brain, a segmentation algorithm might still perform perfectly. The authors argue that we are throwing away valuable data by equating visual aesthetics with algorithmic utility.

Fig. 1: Two scans failing visual QC due to motion artefacts. a) The artefact located in the brain and affecting downstream gray matter segmentation task. b) Artefact localised at the bottom of the image, leaving the brain unaffected. From an algorithmic point of view, this image could have been used, highlighting the distinction between visual and algorithmic QC.

Methods

The researchers developed a Bayesian 3D U-Net designed for image reconstruction. Unlike standard networks that just output a "cleaned" image, this model uses a heteroscedastic uncertainty model. This means the network outputs two things for every pixel:

  1. A predicted "clean" intensity value ($f_W(x)$).
  2. A predicted variance or uncertainty ($\sigma^2$), representing the non-recoverable component of the data corruption.

To prove the distinction between visual and algorithmic quality, they extended this into a multi-task architecture. A shared encoder feeds into two separate decoders: one for image reconstruction (measuring overall visual quality) and one for cortical gray matter (CGM) segmentation (measuring task-specific algorithmic quality).

Fig. 6: Multi-task learning architecture. The predicted mean and variance are estimated for the regression and segmentation tasks, which share the encoder but have separate decoders. The task-specific loss functions Lreg and Lseg are combined to yield the total multi-task loss. The reconstruction uncertainty σr captures the overall “algorithmic quality” of the input x, while the segmentation uncertainty σs reflects the specific “task uncertainty.”

Datasets

  • ADNI (Alzheimer’s Disease Neuroimaging Initiative): The primary source of data.
  • Training Set: 272 MPRAGE scans deemed "artifact-free" by experts.
  • Simulated Data: To create a ground truth for "clean" vs "noisy," the authors injected simulated k-space artifacts and Rician noise into the clean scans.
  • Real-world Evaluation: 106 test-retest pairs from ADNI, where one scan was labeled "clean" and the other "containing artifacts" by human raters.

Key Insights and Ideas

  • Uncertainty as a Quality Metric: The model's predictive uncertainty ($\sigma$) acts as a direct proxy for image quality. High uncertainty indicates areas where the corruption is so severe that the original signal cannot be recovered.
  • Decoupling Quality Types: By using two decoders, the authors demonstrated that reconstruction uncertainty can spike (indicating poor visual quality) while segmentation uncertainty remains low (indicating high algorithmic quality), provided the noise doesn't interfere with the target anatomy.
  • Catching Human Error: Interestingly, the model predicted high uncertainty on some scans labeled "clean" by experts. Upon closer inspection, these scans actually contained subtle artifacts that the human raters had missed.

Key Results

  • Strong Correlation: The predicted uncertainty showed a strong positive correlation with the actual reconstruction error, with an average $R^2$ of 0.851 across test cases.
  • Validation of the "Algorithmic" Hypothesis: In experiments with partial noise, the reconstruction uncertainty increased significantly, reflecting a drop in perceptual quality. However, the segmentation task variance remained stable, proving the algorithm could still "see" through the noise to perform its specific task.
Fig. 3: Median image reconstruction error vs uncertainty as measured by the standard deviation σ. Errorbars represent the 1st and 3rd quartiles of the σ distribution for a given image.

Limitations and Future Work

The authors noted that training on real-world "clean/artifact" pairs is challenging because geometric misalignments between the two scans can sometimes overshadow the actual artifacts, leading the model to focus on alignment errors rather than image quality.

Future work could involve expanding this framework to other downstream tasks (like white matter hyperintensity detection) and integrating it into real-time clinical workflows to provide immediate feedback to radiographers during the scanning process.

Summary updated

Abstract

Quality control (QC) in medical image analysis is time-consuming and laborious, leading to increased interest in automated methods. However, what is deemed suitable quality for algorithmic processing may be different from human-perceived measures of visual quality. In this work, we pose MR image quality assessment from an image reconstruction perspective. We train Bayesian CNNs using a heteroscedastic uncertainty model to recover clean images from noisy data, providing measures of uncertainty over the predictions. This framework enables us to divide data corruption into learnable and non-learnable components and leads us to interpret the predictive uncertainty as an estimation of the achievable recovery of an image. Thus, we argue that quality control for visual assessment cannot be equated to quality control for algorithmic processing. We validate this statement in a multi-task experiment combining artefact recovery with uncertainty prediction and grey matter segmentation. Recognising this distinction between visual and algorithmic quality has the impact that, depending on the downstream task, less data can be excluded based on ``visual quality" reasons alone.
BibTeX
@misc{shaw2021estimating,
  author = {Richard Shaw and Carole H. Sudre and Sebastien Ourselin and M. Jorge Cardoso},
  title = {{Estimating MRI Image Quality via Image Reconstruction Uncertainty}},
  year = {2021},
  eprint = {2106.10992},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2106.10992},
}

Loading related content...

Figure