Abstract
Diagnostic AI systems have achieved expert-level performance in medical imaging but can still fail in cases where clinicians succeed, and vice versa. We present the Complementarity-driven Deferral-to-Clinical Workflow (CoDoC) system, which learns to optimally select between AI and clinician decisions. CoDoC is compatible with various AI models and enhances accuracy in breast cancer and tuberculosis screening. Notably, it exceeded the "gold standard" of double-reading in a UK breast cancer screening program, reducing false positives by 25% and clinical workload by 66%.
Introduction: The Challenge of Human-AI Complementarity
While deep learning models often match or exceed human performance in specific diagnostic tasks, they possess different "failure modes" than human experts. An AI might be tripped up by rare image artifacts that a human easily dismisses, while a human might overlook subtle patterns that an AI identifies instantly. The goal of CoDoC is to leverage this complementarity by determining when to trust the AI and when to defer to a clinician.
Existing "learning to defer" methods often require retraining the diagnostic AI, which is impractical for "locked" medical devices regulated by health authorities. CoDoC addresses this by acting as a modular wrapper that optimizes the hand-off without altering the underlying AI model.
The CoDoC Framework
CoDoC operates by analyzing the confidence scores of a pre-existing diagnostic AI and comparing them against historical clinician performance. The system calculates an "advantage function" to decide if deferring to a clinician is likely to improve diagnostic outcomes (sensitivity or specificity).
A key technical innovation in CoDoC is the use of Kernel Density Estimation (KDE) to smooth the advantage function. This approach mitigates "underspecification"—a common issue where multiple thresholds appear equally effective on small datasets but fail to generalize. By finding robust "zero-crossings" in the smoothed function, CoDoC ensures stable performance even when tuned on limited data (as few as 40 cases).
Experimental Validation and Results
The researchers evaluated CoDoC across diverse medical imaging modalities and clinical settings:
Breast Cancer Screening
- UK Dataset: In a representative screening program (60,755 cases), CoDoC became the first system to outperform the "gold standard" of double-reading with arbitration. It achieved a 25% reduction in false positives while maintaining cancer detection rates and reducing clinician workload by 66%.
- US Datasets: CoDoC exceeded the accuracy of single-reading by board-certified radiologists and two different state-of-the-art AI systems, demonstrating robustness across different manufacturers and populations.
Tuberculosis (TB) Screening
Using 23,954 chest X-rays from Bangladesh, CoDoC was tested against five commercially available AI systems. For three of these systems, CoDoC significantly improved specificity, reducing false positives by 5–15% while maintaining sensitivity.
Discussion and Future Directions
CoDoC demonstrates that the best diagnostic outcomes often come from a strategic partnership between humans and machines. By treating the AI as a "black box," CoDoC is highly adaptable to third-party tools and real-world clinical environments.
However, the study notes certain limitations. It assumes independent interpretations by clinicians and AI, whereas in practice, clinicians often use AI as an assistive tool, potentially introducing automation bias. Furthermore, while retrospective results are compelling, prospective clinical trials are necessary to validate how CoDoC performs in real-time human-AI interactions. To facilitate further research, the authors have open-sourced the CoDoC implementation.
Summary updated