Enhancing CCTA image quality: a review of deep learning approaches for advanced artifact correction and denoising

Mohanad Alkhodari, Eman Alefishat, Herbert F. Jelinek, Ahmed Kaabneh, Panos LiatsisArtif. Intell. Rev 2025 · DOI

This review paper, published in Artificial Intelligence Review (2025), provides a comprehensive look at how deep learning is transforming Coronary Computed Tomography Angiography (CCTA). By moving beyond traditional mathematical reconstruction, researchers are using neural networks to clean up the "noise" and physical artifacts that have long plagued cardiac imaging.

TL;DR

The paper evaluates deep learning architectures—specifically CNNs, GANs, and Diffusion Models—designed to correct CCTA artifacts like motion blur, calcium blooming, and low-dose noise. It highlights a shift from simple pixel-level denoising toward physics-informed, 3D-aware models that improve the diagnostic accuracy of coronary artery disease.

What Problem Does This Paper Address?

CCTA is the primary non-invasive tool for diagnosing coronary artery disease (CAD), but it is a "noisy" modality. To minimize patient radiation exposure, clinicians often use low-dose scans, which result in grainy, low-quality images. Furthermore, the physics of X-rays and the dynamic nature of the heart create three major types of artifacts:

  1. Blooming: High-density calcium deposits or metal stents appear larger than they are, leading to the overestimation of arterial narrowing (stenosis).
  2. Beam Hardening: X-rays "harden" as they pass through dense objects, creating dark streaks that can mimic ischemia.
  3. Motion Artifacts: The heartbeat and breathing cause blurring, especially in patients with high or irregular heart rates.

Traditional reconstruction methods like Filtered Back Projection (FBP) are linear and struggle to handle these complex, non-linear distortions.

Methods

The authors categorize the deep learning "toolbox" for CCTA into several distinct approaches:

  • Discriminative Models (CNNs, ResNets): These supervised models learn a direct mapping from noisy, artifact-laden images to high-quality "ground truth" scans.
  • Generative Models (U-Nets, GANs): U-Nets are favored for their skip connections that preserve spatial detail. Generative Adversarial Networks (GANs) are used to ensure "perceptual plausibility," preventing the over-smoothing common in standard denoising.
  • Diffusion Models: A newer frontier that learns to reverse a noise process, showing high potential for perceptual quality but requiring significant computational power.
  • Physics-Informed AI: Rather than treating the image as just pixels, these models incorporate the Beer-Lambert law and other X-ray physics to ensure structural consistency.

Datasets

The review surveys studies utilizing a mix of data sources:

  • Public Benchmarks: Most notably the CT Grand Challenge (McCollough 2016).
  • Clinical/Local Datasets: Ranging from small cohorts (10 patients) to larger multi-center studies (566 patients).
  • Synthetic Data: Many studies use simulated Poisson noise or mathematically generated motion/metal artifacts to train models when perfectly aligned "clean" clinical pairs are unavailable.

Key Insights and Ideas

  • Architecture-Task Fit: CNNs are highly effective for local artifacts like blooming, whereas U-Nets are superior for segmentation-related tasks due to their hierarchical feature extraction.
  • The 3D/4D Necessity: The authors argue that 2D models are insufficient for the heart. Future work must focus on 3D/4D convolutions to maintain "inter-slice continuity," ensuring that a vessel looks consistent as you scroll through the volume.
  • Beyond PSNR: While technical metrics like Peak Signal-to-Noise Ratio (PSNR) are standard, they don't always correlate with clinical utility. The paper advocates for "task-based metrics," such as diagnostic accuracy in lesion detection.
  • Commercial Integration: Major vendors are already deploying these "black box" models (e.g., Canon’s AiCE, GE’s TrueFidelity), signaling that AI-enabled reconstruction is no longer just academic—it is the new clinical standard.

Key Results

  • Denoising Performance: Top-performing models have achieved PSNR levels up to 47.00 dB and Structural Similarity Index (SSIM) scores of 0.98.
  • Motion Correction: Specialized architectures like ATOM (Attention and Spatial Transformer) have significantly improved visualization for patients with heart rates >60 bpm, where traditional gating often fails.
  • Blooming Reduction: GAN-based models have reached up to 81.3% sensitivity in identifying calcified plaques while reducing the false-positive rate for stenosis.

Limitations and Future Work

Despite the progress, several hurdles remain:

  • Generalizability: Most models are trained on data from a single scanner vendor. They often fail when applied to images from different hardware (the "domain shift" problem).
  • Interpretability: There is a critical lack of Explainable AI (XAI). Clinicians need to know if a model removed a streak or if it accidentally erased a small, life-threatening soft plaque.
  • Computational Overhead: Advanced models like Diffusion architectures require massive GPU resources (24GB+ VRAM) and long inference times, making them difficult to integrate into fast-paced emergency rooms.
  • Clinical Validation: The field needs more prospective, multi-center clinical trials to prove that AI-enhanced images actually lead to better patient outcomes, not just "prettier" pictures.

Summary updated

BibTeX
@article{alkhodari2025enhancing,
  author = {Mohanad Alkhodari and Eman Alefishat and Herbert F. Jelinek and Ahmed Kaabneh and Panos Liatsis},
  title = {{Enhancing CCTA image quality: a review of deep learning approaches for advanced artifact correction and denoising}},
  journal = {Artif. Intell. Rev.},
  year = {2025},
  doi = {10.1007/s10462-025-11311-w},
}
Figure