TL;DR
This paper introduces the use of plasma focused ion beam-scanning electron microscopy (PFIB-SEM) for high-resolution 3D imaging of human cortical bone. It reveals a previously underappreciated ellipsoidal mesoscale mineralization pattern, suggesting a more complex organization of mineral within bone than previously understood.
What Problem Does This Paper Address?
Understanding the intricate structure of bone, particularly the organization of mineral within collagen fibrils and at larger scales, is crucial for comprehending its mechanical properties and how it responds to disease and injury. While techniques like transmission electron microscopy (TEM) offer high resolution, they are limited to very small volumes. Traditional focused ion beam-SEM (FIB-SEM) allows for larger volumes but can be slow. The challenge lies in visualizing bone's hierarchical structure across multiple length scales, from nanometers to micrometers, with sufficient resolution and speed to capture both mineral organization and the lacuno-canalicular network (LCN) that houses osteocytes. This paper addresses the need for a technique that can bridge this gap, enabling the study of larger volumes of mineralized bone at high resolution.
Methods
The core technique employed is Plasma Focused Ion Beam-Scanning Electron Microscopy (PFIB-SEM). This advanced FIB-SEM uses a Xenon plasma ion source, offering significantly faster material removal rates (20-60x) compared to traditional Gallium-based FIB-SEM. This speed increase allows for the acquisition of larger 3D volumes with nanoscale resolution. The authors also utilized standard SEM sample preparation techniques, including dehydration and embedding, for both demineralized and mineralized bone samples. For data processing and visualization, they employed Dragonfly software, including cross-correlation alignment and manual segmentation for the LCN.
Datasets
The study utilized human cortical bone samples. Specifically, they analyzed both demineralized and mineralized sections of a human femur from a 68-year-old male. The PFIB-SEM serial sectioning generated 3D volumes of approximately 45.8 x 40.9 x 8.7 µm³ for demineralized bone and 28.6 x 25.6 x 8.7 µm³ for mineralized bone.
Key Insights and Ideas
- PFIB-SEM is a game-changer for bone imaging: The increased speed of PFIB-SEM opens up possibilities for analyzing larger volumes of bone at nanoscale resolution, bridging the gap between traditional TEM and lower-resolution techniques.
- Mineralized bone imaging is essential: Analyzing mineralized bone directly, without demineralization and staining, provides crucial insights into mineral organization that are lost in demineralized samples.
- Ubiquitous ellipsoidal mineral clusters: The study reveals that mineral in human cortical bone is not just organized within collagen fibrils but also forms distinct ellipsoidal clusters at the mesoscale (approximately 1.1 µm in length by 700 nm in diameter).
- Hierarchical organization of mineral: These ellipsoidal clusters represent a significant level of mineral organization above the collagen fibril level and below the osteon lamella, suggesting a more complex and patterned mineralization process.
- "Rosette" features are part of larger ellipsoids: The previously observed "rosette" features in TEM are identified as the cross-sectional view of these larger ellipsoidal mineral clusters.
Key Results
- PFIB-SEM successfully acquired 3D volumes of human cortical bone at nanoscale resolution (20 nm voxel size for demineralized, 12.5 nm for mineralized).
- The study identified prolate ellipsoidal mineral clusters measuring on average 1.14 ± 0.26 µm in length and 700 ± 164.4 nm in diameter.
- These ellipsoidal clusters were found to be ubiquitous throughout the analyzed 45 µm section of lamellar bone.
- The technique allowed for the visualization of both the mineral clusters and the lacuno-canalicular network (LCN) within the same volume, with canaliculi diameters averaging 346 ± 146 nm in demineralized bone and 285 ± 82 nm in mineralized bone.
Limitations and Future Work
- Limited sample size: The study analyzed only one demineralized and one mineralized dataset from a single anatomical location and orientation. Future work should include a wider range of samples, anatomical locations, and species.
- Preparation artifacts: While PFIB-SEM is powerful, the samples were prepared using dehydration and embedding, not cryogenic methods, which might affect cellular details. Future work could explore cryo-PFIB-SEM.
- Volume limitations: Although PFIB-SEM allows for larger volumes than TEM, the probed volumes are still relatively small for capturing entire osteons or multiple osteocytes and their connections. Future work should aim to image even larger volumes.
- Age of osteon: The age of the osteon and specific lamella probed was unknown. Future studies could compare primary and secondary osteons to understand if the ellipsoidal structure is transient or permanent.
- Mineralization mechanism: While the study confirms the ellipsoidal shape, further work is needed to fully elucidate the intra- and interfibrillar mineralization mechanisms and how these clusters form.
- Elemental analysis: Integrating elemental analysis (e.g., EDX) with PFIB-SEM could provide further insights into mineral composition and distribution.
Summary updated