Elimination of shunting conductance effects in a low-cost capacitive-sensor interface
Abstract
A low-cost and reliable interface for capacitive sensors, based on the use of a relaxation oscillator and a microcontroller, is presented. The novel interface system is designed to measure small capacitances in a reliable and accurate way even when the sensor capacitors are shunted by parasitic conductances. The problem of shunting conductances is solved by performing a series of eight measurements and using a new auto-calibration technique. Moreover, all multiplicative and additive errors of the interface are also eliminated by using this new auto-calibration technique. In the microcontroller, the final result is calculated based on the new measurement algorithm. A prototype has been built and tested. Experimental results show that the interface is able to measure a capacitance of 0-1.2 pF with a shunting conductance of up to 0.42 /spl mu/S, with a resolution and a relative accuracy of 0.03% and /spl plusmn/0.15%, respectively. The measurement time is about 400 ms.
BibTeX
@article{li2000elimination,
author = {Xiujun Li and Gerard C. M. Meijer},
title = {{Elimination of shunting conductance effects in a low-cost capacitive-sensor interface}},
journal = {IEEE Trans. Instrumentation \& Measurement},
year = {2000},
url = {https://openreview.net/forum?id=l_B-ns87-FD},
}Ask Althea to put this paper to the test.