Efficient Factorized Volume Synthesis with Lifted Inter-Slice Feature Trajectories

Xinhe Zhang, Yuyang Zhang, Pengfei Jin, Arnau Marin-Llobet, Na Li, Quanzheng LiNeurIPS 2026

TL;DR

Generating 3D medical scans usually forces a frustrating choice: use massive, painfully slow 3D models, or fast 2D slice generators that produce jagged, incoherent anatomy when stacked together. LiFT (Lifted inter-slice Feature Trajectories) sidesteps this tradeoff by pairing a heavyweight 2D image generator with a lightweight "trajectory" module that smoothly coordinates features across depth. The result is coherent, high-resolution 3D brain MRI and CT synthesis that runs up to 390× faster than volumetric diffusion baselines.

What Problem Does This Paper Address?

Clinical imaging is inherently three-dimensional—tumors, ventricles, and skull boundaries are continuous structures, not isolated 2D snapshots. When synthesizing medical data (say, generating a CT scan from an MRI to plan radiation therapy, or filling in a missing MRI contrast), the output must hold together across all three spatial axes.

Currently, fully 3D generative models capture this volumetric structure well, but they devour GPU memory, forcing compromises on image resolution or inference speed. Conversely, mature 2D generators easily produce crisp, high-resolution slices at a fraction of the compute cost. However, if you generate slices independently and stack them like a deck of cards, the cards don't align—view the resulting 3D volume from the side (coronal or sagittal views), and you get jagged discontinuities and shifting anatomy.

Figure 1: Conceptual motivation: LiFT organizes slice representations into coherent depth trajectories.

The authors ask: if a strong 2D model already knows how to draw crisp anatomy within a slice, can we add 3D coherence with a tiny, separate module instead of redesigning the whole generator?

Methods

LiFT factorizes 3D synthesis into two distinct jobs: in-plane image formation (handled by standard 2D networks) and through-plane organization (handled by a lightweight trajectory module). Viewing a 3D volume as a smooth path through feature space across depth ($z$), LiFT adapts its architecture to two supervision regimes:

Figure 2: LiFT factorizes volume synthesis into a 2D synthesizer and an inter-slice trajectory module.
  • Unconditional Generation (LiFT-U): Here, the goal is generating realistic 3D brain MRIs from random noise without paired ground-truth targets. The authors pretrain and freeze a standard 2D axial slice generator. They then train a tiny 1.45M-parameter "depth mapper" that takes global noise plus a Fourier-encoded depth coordinate to output ordered, per-slice conditioning vectors. To ensure the stacked volume looks right from every angle, they introduce a tri-planar drifting loss: slicing the generated 3D volume along axial, coronal, and sagittal planes, extracting features via a frozen ResNet-18, and pulling those feature distributions toward real scans (and away from other generated samples in the batch).
  • Conditional/Paired Translation (LiFT-C): When translating a source scan into a registered target scan (e.g., MR-to-CT), LiFT-C uses a 2D U-Net encoder–decoder. All 2D encoders and skip connections remain strictly two-dimensional. Only at the spatial bottleneck does a bidirectional $z$-context mixer (a lightweight recurrent bidirectional GRU) step in, passing spatial context up and down the slice stack before the 2D decoder reconstructs the final volume under direct target supervision.

Datasets

No new datasets are introduced; the authors evaluate on two established public 3D brain imaging benchmarks:

  • BraTS 2023 GLI: Used for unconditional 3D T1n MRI generation ($128^3$ isotropic resolution) and paired missing-modality MRI synthesis ($240 \times 240 \times 155$ native resolution, predicting one missing MRI contrast from three available ones).
  • SynthRAD2023 (Task 1 Brain): Used for paired T1-weighted MR-to-CT translation ($128^3$ crops across 180 subjects split 80/20).

Key Insights and Ideas

  • 3D synthesis as a "lifting" problem: You don't need dense 3D convolutions everywhere to build a coherent volume. Confining cross-slice communication to conditioning codes or low-resolution spatial bottlenecks is enough to coordinate how anatomical structures appear, morph, and vanish across depth.
  • Standard metrics miss the 3D story: In paired MR-to-CT translation, adding inter-slice context gives only modest bumps on conventional pixel-wise metrics like PSNR or MAE. However, when looking at adjacent-slice difference ($\Delta_z$) metrics—which directly measure jaggedness along the depth axis—errors drop dramatically. Aggregate 3D reconstruction scores can easily hide through-plane incoherence.
  • Zero-cost architectural modularity: By injecting depth context via zero-initialized residual connections, the authors can toggle the 3D trajectory mixer on and off at inference time on the exact same checkpoint, cleanly isolating the effect of depth coordination.

Key Results

Tested on a single NVIDIA RTX 5090 GPU, LiFT matches volumetric baselines at near-2D speeds:

  • Unconditional Brain MRI: LiFT-U achieves a competitive FID ($\times 10^3$) of 0.066 in just 0.039 seconds per volume using 30.3M parameters—running ~390× faster with 5.5× fewer parameters than 3D MedDiffusion (0.043 FID, 15.37s), and outperforming WDM (0.154 FID, 26.92s) and MAISI-v2 (0.294 FID, 0.506s).
  • Missing-Modality MRI: LiFT-C reaches 28.417 dB PSNR and 0.9528 SSIM, essentially tying the 1000-step volumetric diffusion model cWDM (28.425 dB PSNR, 0.9525 SSIM) while running ~133× faster (1.17s vs. 154.8s). Toggling on the context mixer slashes the axial-bias SSIM gap by 48.4%.
  • MR-to-CT Translation: LiFT-C tops all baselines on standard metrics (54.09 HU MAE, 0.9355 SSIM). More importantly, compared to disabling its depth context, LiFT-C reduces adjacent-slice $\Delta_z$ MAE by 10.2% overall, 11.1% in bone, and 13.1% in air cavities.

Limitations and Future Work

Because LiFT separates 2D image creation from 3D organization, its ceiling is still bound to the 2D backbone: if the 2D translator struggles with tricky local physics—like distinguishing bone from air interfaces in MR-to-CT—inter-slice smoothing won't magically fix the underlying tissue contrast. Additionally, paired LiFT-C relies heavily on accurate image registration during preprocessing. Finally, all experiments focus on relatively rigid brain anatomy; extending this trajectory-lifting approach to deformable, breathing-affected regions (like the chest or abdomen) and validating it on downstream clinical tasks like radiation dose planning remain key next steps.

Summary updated

Abstract

High-resolution 3D medical image generation remains challenging because fully volumetric models are computationally expensive, while efficient 2D slice generators often fail to preserve anatomical consistency across the third dimension. We propose LiFT, a framework for Lifted inter-slice Feature Trajectories that factorizes 3D volume synthesis into per-slice image generation and inter-slice trajectory learning. Rather than using a fully volumetric synthesis backbone, LiFT treats a volume as an ordered trajectory in feature space, capturing how anatomical structures appear, transform, and disappear across depth. We demonstrate the LiFT framework in both unconditional and conditional settings. In unconditional generation, a tri-planar drifting loss matches feature distributions between generated and real volumes across three orthogonal planes; in paired translation, a bidirectional $z$-context mixer trained with paired target supervision supplies through-plane coherence while preserving per-slice fidelity. We evaluate LiFT on BraTS 2023 for unconditional and missing-modality MR synthesis, and on SynthRAD2023 for MR-to-CT translation. LiFT achieves competitive image quality while retaining the efficiency of predominantly 2D synthesis, operating up to $390\times$ faster than a volumetric diffusion baseline and consistently improving through-plane coherence through explicit inter-slice modeling. These results establish lightweight inter-slice trajectory learning as an efficient approach to high-resolution 3D medical synthesis.
BibTeX
@inproceedings{zhang2026efficient,
  author = {Xinhe Zhang and Yuyang Zhang and Pengfei Jin and Arnau Marin-Llobet and Na Li and Quanzheng Li},
  title = {{Efficient Factorized Volume Synthesis with Lifted Inter-Slice Feature Trajectories}},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2026},
  url = {https://openreview.net/forum?id=sFZ1pRmigE},
}
Figure