Effects of Laser Beam Width and Measurement Noise on Tree Diameter Estimation in Laser Scanning

Jesse Muhojoki, Nuutti Ervasti, Eric Hyyppä, Aapo Erkkilä, Eppu Honkanen, Tuomas Yrttimaa, Mikko Vastaranta, Juha HyyppäarXiv 2026

This study dives into the physics of lidar to solve a persistent problem in forest inventory: why do our mobile laser scanners consistently get tree diameters wrong? By modeling the interaction between laser beam width and measurement noise, the researchers developed a calibration-free method to achieve sub-centimeter accuracy in tree diameter estimation.

TL;DR

Researchers have identified that tree diameter estimation bias in mobile laser scanning (MLS) is driven by a combination of laser beam divergence and heteroscedastic measurement noise. They proposed a novel, simulation-based compensation method that uses only sensor technical specifications to reduce diameter estimation errors to sub-centimeter levels for trees larger than 10 cm.

What Problem Does This Paper Address?

Accurate forest inventories are critical for sustainable management and carbon storage assessment. While Mobile Laser Scanning (MLS) is significantly faster than traditional manual measurements or stationary Terrestrial Laser Scanning (TLS), it often produces biased estimates of tree diameters.

Previous literature has been contradictory, with some studies reporting that lidar overestimates diameters and others reporting underestimation. The gap lies in a lack of fundamental understanding of how scanner-specific characteristics—like the finite width of the laser beam and the nature of measurement noise—interact with the geometry of a tree stem to create these systematic errors.

Methods

The authors employed a three-pronged approach:

  1. Physics-Based Simulations: They modeled a time-of-flight laser scanner, accounting for Gaussian beam divergence and the "smearing" effect when a finite beam hits a curved surface (see Figure 1). Crucially, they simulated heteroscedastic noise, where the precision of the range measurement differs from the precision of the scan angle.
  2. Calibration-Free Compensation: Instead of requiring tedious field calibrations for every new sensor or site, they developed a method that uses a lookup table generated from these simulations. By inputting standard manufacturer specs (beam divergence, ranging precision), the system predicts and negates the expected bias for a given measurement distance and target diameter.
  3. Validation: The method was tested against a controlled artificial cylinder and real-world boreal forest plots. They used standard RANSAC and "hyperaccurate" algebraic circle fitting as the baseline geometric modeling techniques.
Figure 1: a) Beam intensity distribution exiting the sensor. b) Return signal for measurements illustrated in c) (top view, tar- get cylinder in red). The edges are smeared by the finite beam hitting a curved surface. The laser pulse was fired from the ori- gin at an angle of 0, 6, 12 and 18 mrad w.r.t. x-axis. The pulse was 3 ns long with divergence of 2 mrad.

Datasets

  • Simulation Data: Used to explore the parameter space of beam width and noise levels.
  • Laboratory Data: An artificial cylinder (210 mm diameter) covered in cardboard of varying reflectivities (brown, white, black) to isolate the effects of distance and surface properties (see Figure 4).
  • Field Data: 9 sample plots (32m x 32m) in Evo, Finland, representing "easy" (sparse Scots pine) and "difficult" (dense mixed forest) boreal conditions.
  • Reference Data: High-precision TLS point clouds (Riegl VZ-400i) from 16 positions per plot served as the ground truth for tree geometry.

Key Insights and Ideas

  • The Bias Tug-of-War: Beam divergence typically causes overestimation of diameter because the beam "sees" the edges of the tree sooner. Conversely, heteroscedastic noise (where angular precision is much higher than ranging precision) tends to cause underestimation during circle fitting (see Figure 2).
  • Diameter Matters: Bias isn't just a function of distance; it's also sensitive to the tree's actual diameter. This explains why previous studies, which often ignored tree size, reached conflicting conclusions.
  • The 10 cm Threshold: For trees with a Diameter at Breast Height (DBH) > 10 cm, the bias is stable and predictable using only sensor specs. Below this threshold, bias becomes highly sensitive to "unknowns" like bark roughness and the stem's deviation from a perfect circle.
Figure 2: Illustration showing how heteroscedastic noise (b) shifts the fitted circle (dashed black) compared to the true cylinder (red), inducing bias.

Key Results

  • Significant Error Reduction: On forest test sites, the uncorrected Root-Mean-Square Error (RMSE) for stem curves was 14–17 mm. The proposed compensation method slashed this to 5–7 mm—a sub-centimeter level of accuracy.
  • Bias Negation: Systematic bias was reduced from 9–16 mm down to a negligible -2 to 4 mm.
  • Robustness: The method proved effective across different tree species (Pine, Spruce, Birch, Aspen) without needing species-specific tuning, provided the trees were larger than 10 cm in diameter.

Limitations and Future Work

The primary limitation is the "small tree problem." For stems under 10 cm, factors like bark depth and out-of-roundness can outweigh the scanner-induced biases, making simulations less reliable.

Additionally, the current method relies on temporal segmentation (processing "arcs" of laser hits). The authors suggest that future work could involve point-by-point bias compensation applied to the entire point cloud at once, which might further improve robustness against positioning errors in the MLS trajectory. Finally, more detailed modeling of proprietary "range-walk" correction algorithms used by manufacturers could refine the simulation accuracy.

Summary updated

Abstract

Laser scanning has been utilized for decades to measure tree structure and geometry. Despite continuous advances in sensor technology, uncertainties arising from scanner characteristics and measurement conditions has remained relevant sources of error. In particular, factors such as laser beam diameter can introduce both systematic and random errors in the reconstructed tree geometry. This study investigates the main sources of these errors in mobile laser scanning (MLS) and quantifies their effects on stem curve (stem diameter) estimation. We discovered through simulations and experiments that the heteroscedasticity (difference in variance in ranging and scan angle) in the measurement noise is a key factor along with the beam width of the lidar, which cause the bias of the diameter estimates to depend not only on distance, but also on the tree diameter. We demonstrated that this bias can be reliably predicted and negated for trees with a diameter at the breast height greater than 10 cm using technical specifications of the sensor without any additional calibration. In experiments, the proposed bias compensation method reduced the root-mean-square error of stem diameter estimates to sub-centimeter level on boreal forest test sites. However, for small trees with diameter below 10 cm, the diameter bias becomes sensitive to the diameter of the tree$\unicode{x2013}$an unknown factor$\unicode{x2013}$and other factors, such as different bark and out-of-roundness of the stem, limiting the precision of lidar for measuring geometry of trees and applicability of the presented method.
BibTeX
@misc{muhojoki2026effects,
  author = {Jesse Muhojoki and Nuutti Ervasti and Eric Hyyppä and Aapo Erkkilä and Eppu Honkanen and Tuomas Yrttimaa and Mikko Vastaranta and Juha Hyyppä},
  title = {{Effects of Laser Beam Width and Measurement Noise on Tree Diameter Estimation in Laser Scanning}},
  year = {2026},
  eprint = {2611.13739},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.13739},
}
Figure