[Effect of simulated microgravity on peripheral oxygen saturation in rats].
Lists
Only you see this
Abstract
To study the effect of microgravity on peripheral oxygen saturation (SpO <sub>2</sub>) in rats, tail-suspended rats were applied to simulate microgravity environment. SpO <sub>2</sub> and arterial oxygen saturation (SaO <sub>2</sub>) were measured by pulse oximeter and arterial blood gas analyzer (ABGA) respectively on the 14th day, 21st day and 28th day in tail-suspended group and control group. Paired <i>t</i>-test shows that SpO <sub>2</sub> was significantly lower than SaO <sub>2</sub> in tail-suspended group on the 14th day ( <i>P</i> < 0.05), the 21st day ( <i>P</i> < 0.05) and the 28th day ( <i>P</i> < 0.01). The ANOVA results shows that modeling time had significant effect on SpO <sub>2</sub> value but no effect on SaO <sub>2</sub> value in tail-suspended group. These results indicate that pulse oximeter may be not suitable for oxygen saturation test in microgravity environment.
BibTeX
@inproceedings{guangfei2018effect,
author = {Chen Guang-fei and Yahui Zhang and Ming Yuan and Shilin He and Jun Ying and Chen Li},
title = {{[Effect of simulated microgravity on peripheral oxygen saturation in rats].}},
booktitle = {PubMed},
year = {2018},
doi = {10.7507/1001-5515.201701023},
}Loading related content...