TL;DR
This study investigates the impact of freezing saturated sandy soil on buried steel pipes through a full-scale model test. It reveals that even non-frost susceptible sandy soils can cause significant frost heaving and pipe displacement under undrained conditions, highlighting the critical role of drainage and water content in preventing pipe damage.
What Problem Does This Paper Address?
Buried water pipes are vulnerable to damage from ground freezing and thawing, particularly in regions with increasing cold wave intensity. This phenomenon can lead to excessive ground stress, frost heaving, and differential settlement, ultimately causing pipe rupture or deformation. While existing studies offer methods for predicting ground expansion, there's a notable lack of full-scale experimental data to understand the stress behavior of buried pipes under these conditions. This paper aims to fill that gap by simulating freezing conditions and observing their effects on a buried steel pipe, even when using materials generally considered safe from frost heaving.
Methods
The researchers conducted a full-scale model chamber test to simulate the actual behavior of a buried pipe under freezing conditions. The test involved a large chamber (2m x 2m x 1.5m) designed to withstand low temperatures. A non-frost susceptible Jumunjin sand was used as backfill material, compacted and saturated to mimic challenging ground conditions. The chamber was subjected to a controlled freezing temperature of -15°C. To monitor the effects, various instruments were employed:
- Temperature sensors: Placed at different depths to track ground temperature variations.
- Strain gauges: Attached to the buried pipe to measure stress and deformation.
- LVDT (Linear Variable Differential Transformer): Connected to the pipe to directly measure displacement.
The test simulated both freezing and thawing cycles. The data collected allowed for the analysis of ground temperature distribution, pipe displacement, and the estimation of frost heaving force.
Datasets
Not discussed in the paper. The study relies on data generated from their own experimental setup.
Key Insights and Ideas
- Frost heaving is a significant risk even with "non-frost susceptible" soils: The most striking finding is that Jumunjin sand, classified as non-frost susceptible, still exhibited frost heaving when saturated and under undrained conditions. This challenges the assumption that using such materials alone guarantees safety.
- Drainage and water content are critical: The study emphasizes that frost heaving is heavily influenced by ground saturation and drainage conditions. Poor drainage, even with suitable soil, can lead to significant heaving.
- Freezing and thawing cycles cause complex pipe behavior: The research observed that pipe heaving and displacement occur not only during freezing but also during thawing, driven by the movement of pore water.
- Significant pipe displacement and stress: The full-scale test revealed substantial displacement (up to 20.2mm, or 40.4% of pipe diameter) and bending tensile stress (805.2 MPa) in the buried pipe, exceeding allowable limits and the yield strength of the steel, respectively. This indicates a high risk of performance deterioration and potential failure.
- Spring heaving is a concern: The study suggests that pipe rupture in spring might be linked to potential heaving forces generated by the movement of melted pore water, underscoring the need for thorough site investigations.
Key Results
- Frost Heaving: Even with saturated Jumunjin sand (non-frost susceptible), frost heaving occurred, resulting in a swelling of 3.84mm and a heaving pressure of 839.1 kPa in a smaller-scale test.
- Pipe Displacement: In the full-scale test, the maximum displacement of the buried pipe reached 20.2mm, which is 40.4% of the pipe's 50mm diameter. This significantly exceeds the allowable deflection of 5% for water pipe design.
- Bending Tensile Stress: The calculated bending tensile stress on the top of the buried pipe was 805.2 MPa, exceeding the yield tensile stress of the steel member (380 MPa).
- Freezing Index: The test achieved a freezing index of 300 °C·day, comparable to a 10-year intensity freezing index in Seoul and Gyeonggi areas, making the results relevant for predicting winter behavior.
Limitations and Future Work
- Limitations:
- The study acknowledges that the test was conducted under controlled laboratory conditions, which may not perfectly replicate all real-world complexities.
- While the sand used was considered non-frost susceptible, the specific properties and the degree of saturation were key factors in inducing heaving.
- Future Work:
- The authors suggest that site investigation is crucial to verify the reliability of their findings and to assess the potential heaving forces in spring.
- Further research is needed to understand how varying ground drainage conditions, groundwater levels, and water content influence frost heaving, even when using materials intended to be frost-resistant.
- The study implies a need for developing more robust countermeasures to protect buried pipes from frost heaving, beyond simply selecting non-frost susceptible backfill materials.