Effect of absorption enthalpy on temperature-swing CO2 separation process performance

Ernst A. van Nierop, Sahand Hormoz, Kurt Zenz House, Michael J. AzizEnergy 2011 · DOI

Abstract

We model a CO2 absorption process to elucidate the rationale for the search for a solvent with an enthalpy of absorption (ΔH) of low magnitude. We explore the relationship between ΔH and the system’s performance. While in general a lower magnitude appears to provide better system performance because it permits the stripper temperature to be decreased, as the magnitude drops below its value for monoethanolamine amine (MEA), 80 kJ/mol, the required solvent mass flow rate must increase precipitously and/or the flue gas must be cooled significantly. We argue that the associated parasitic pumping and cooling loads, as well as the increased capital cost, may set a practical lower limit on the magnitude of the enthalpy of absorption that is not very different from that of MEA.
BibTeX
@inproceedings{nierop2011effect,
  author = {Ernst A. van Nierop and Sahand Hormoz and Kurt Zenz House and Michael J. Aziz},
  title = {{Effect of absorption enthalpy on temperature-swing CO2 separation process performance}},
  booktitle = {Energy},
  year = {2011},
  doi = {10.1016/j.egypro.2011.02.054},
}

Loading related content...

Figure