Effect Inference From Two-Group Data With Sampling Bias

Dave Zachariah, Petre StoicaIEEE Signal Processing Letters 2019 · OpenReview

TL;DR

This paper introduces a novel statistical method for comparing two groups of data that are prone to sampling bias. The proposed approach is more robust than standard methods, effectively controlling false positive error rates even when data collection isn't perfectly representative of the target populations. This is crucial for reliable scientific conclusions in fields where biased sampling is common.

What Problem Does This Paper Address?

In many real-world scenarios, we want to compare two groups (e.g., a control group and a treatment group) to understand the effect of an intervention or difference. The standard approach is to calculate the difference in the average values (means) of the two groups. However, a significant challenge arises when the data collected for each group isn't a true reflection of the entire population it's supposed to represent – this is known as sampling bias. When sampling bias is present, standard statistical methods can lead to incorrect conclusions, specifically by falsely identifying a significant effect when none truly exists (false positives). This paper tackles the problem of making reliable inferences about group differences when such sampling biases are a concern.

Methods

The authors propose a new inference method that is "resilient" to sampling biases. The core idea is to use a statistical model that assumes the unknown effect (the difference between group means) is more likely to be close to zero. This is achieved by modeling the effect $\delta$ as a random variable following a Gaussian distribution with a mean of 0 and a variance $\lambda$, i.e., $\delta \sim \mathcal{N}(0, \lambda)$. The parameter $\lambda$ is treated as an unknown nuisance parameter.

The method then estimates the unknown parameters of the model (including the overall mean $\mu$, the variances of the two groups $\nu_0, \nu_1$, and the bias parameter $\lambda$) using a maximum likelihood approach on a marginalized data distribution. A key innovation is the use of a "fully automatic and data-adaptive regularization" of the effect estimator. This regularization effectively "shrinks" the estimated effect towards zero when the data is not sufficiently informative, thus mitigating the impact of sampling bias. The paper derives a confidence interval for the effect that is designed to maintain a specified coverage probability (the chance of correctly containing the true effect) even under moderate bias.

Datasets

The paper evaluates its proposed method using two types of data:

  • Synthetic data: Generated according to the described two-group model with introduced negative bias. This allows for controlled testing of the method's performance under known bias conditions.
  • Real biomarker data: Data from a study comparing healthy individuals and individuals with prostate cancer, involving 6033 different biomarker responses. This dataset is used to demonstrate the practical applicability of the method on real-world biological data.

Key Insights and Ideas

  • Bias is a significant problem for standard inference: The paper clearly demonstrates (e.g., in Figure 1) that standard methods like Welch's t-test are highly susceptible to false positives when sampling bias is present.
  • Regularization as a bias mitigation tool: By modeling the effect as more likely to be zero and adaptively regularizing the estimator, the proposed method effectively counters the spurious signals introduced by bias.
  • Controlling false positives without sacrificing too much power: The method aims to keep the false positive rate below a desired threshold (e.g., 5%) while incurring only a vanishing loss in statistical power as the sample size increases. This is a crucial trade-off for reliable scientific discovery.
  • Data-adaptive approach: The regularization is not fixed but adapts based on the data itself, making it more flexible and robust than pre-defined regularization schemes.
  • Empty intervals indicate lack of information: In some cases, the proposed method yields empty confidence intervals, which the authors interpret as the data not being informative enough to discern a systematic effect from noise. This is a valuable diagnostic feature.

Key Results

  • Reduced False Positive Errors: Figure 3(a) shows that the proposed method successfully controls the probability of false positive errors to below the nominal level ($\alpha = 0.05$) even with increasing sample sizes, whereas the standard method's error rate increases with sample size under bias.
  • Negligible Loss in Power: Figure 3(b) illustrates that the probability of false negative errors (missing a true effect) for the proposed method is comparable to the standard method, especially as sample sizes grow.
  • Application to Biomarker Data: The method identified 6 significant effects in the prostate cancer biomarker dataset at the $\alpha = 0.05$ level. In contrast, the standard Welch's t-intervals identified 478 genes, suggesting that many of these might be spurious findings due to potential biases in the data.
  • Visualizing the effect of regularization: Figure 2 shows that when the true effect is zero and bias is present, the proposed method's estimates are concentrated around zero, unlike the standard method which shows a wider spread.

Limitations and Future Work

  • Moderate Bias Assumption: The paper focuses on controlling false positive errors under "moderate bias levels." The performance under severe or extreme biases is not explicitly detailed.
  • Unknown Nuisance Parameters: While the method estimates nuisance parameters adaptively, the accuracy of these estimates and their impact on the final inference under various bias scenarios could be further explored.
  • Future Work: The authors suggest that the method's performance can be further improved by exploring more sophisticated regularization techniques and by investigating its applicability to more complex experimental designs beyond simple two-group comparisons. The code for the method is made publicly available, encouraging further research and application.

Summary updated

Abstract

In many applications, different populations are compared using data that are sampled in a biased manner. Under sampling biases, standard methods that estimate the difference between the population means yield unreliable inferences. Here, we develop an inference method that is resilient to sampling biases and is able to control the false positive errors under moderate bias levels in contrast to the standard approach. We demonstrate the method using synthetic and real biomarker data.
BibTeX
@article{zachariah2019effect,
  author = {Dave Zachariah and Petre Stoica},
  title = {{Effect Inference From Two-Group Data With Sampling Bias}},
  journal = {IEEE Signal Processing Letters},
  year = {2019},
  url = {https://openreview.net/forum?id=pb3atRkCM5j},
}
Figure