Abstract
Vehicle-to-Grid (V2G) technology is often discussed in the context of passenger vehicles, yet it faces significant challenges due to unpredictable usage patterns and "range anxiety." This study investigates the application of V2G in the Non-Road Mobile Machinery (NRMM) sector, specifically within rental fleets. Using a two-layer optimization framework, we demonstrate that the high predictability and large battery capacities of machinery like electric tractors make them ideal for grid integration. Our findings show that while regulatory hurdles like double taxation persist, bidirectional charging infrastructure can be economically viable, turning rental hubs into active participants in the energy market.
Introduction
While V2G is a prominent topic for passenger electric vehicles (EVs), it faces hurdles like unpredictable parking patterns. Non-Road Mobile Machinery (NRMM)—including tractors, excavators, and loaders—presents a different opportunity. These machines feature massive batteries and, crucially, highly predictable work schedules with long idle periods. This paper addresses the technical and economic feasibility of transforming an NRMM rental dealership into a "smart hub," determining if revenue from grid services and energy cost savings can offset the investment costs of bidirectional charging infrastructure and stationary batteries.
Methods
The researchers developed a two-layer optimization framework to simulate a year of operation for a fleet of ten electric tractors:
- The Inner Layer (Operational): An Energy Management System (EMS) uses Linear Programming to minimize weekly electricity costs. It decides when to charge from the grid, when to use solar power (PV), and when to sell energy back to the grid based on real-world "day-ahead" market prices.
- The Outer Layer (Design): This layer uses Bayesian Optimization (BO) to find the optimal hardware sizing. It iterates through combinations of PV peak power, stationary battery (BESS) capacity, grid connection limits, and specific charging station (EVSE) types to find the configuration with the lowest total annual cost.
The simulation assumes a "perfect foresight" model where the system knows the upcoming week's weather and tractor schedules exactly.
Data and Assumptions
The study relies on several data sources to create a realistic simulation:
- Solar Data: Historic irradiation data from Aldenhoven, Germany, to simulate PV production.
- Market Prices: Day-ahead energy market prices from aWATTar (2023 data).
- Usage Profiles: Three synthetic "use cases" representing typical rental patterns (e.g., machines rented for the whole week vs. daily rentals).
- Cost Benchmarks: A detailed breakdown of component costs (PV, BESS, various EVSE power levels) and their expected lifetimes for depreciation calculations.
Results and Discussion
The Bayesian Optimization settled on an optimal system configuration consisting of 133.9 kWp of PV, a 99.0 kWh stationary battery, and a 69.4 kW grid connection. Through smart bidirectional charging and solar integration, the dealership achieved a profit of €695 per year on electricity exchange alone, prior to accounting for hardware depreciation.
As shown in the operational data, the system successfully shifted heavy charging loads to mid-day (peak solar) and mid-night (low demand), while discharging to the grid during high-price morning and evening peaks.
Key Insights
- Predictability is a Superpower: Unlike private car owners, rental fleets have scheduled returns. This allows the optimizer to discharge a tractor's battery into the grid or building (V2B/V2G) with confidence, knowing exactly when it needs to be recharged for the next customer.
- The "Double Taxation" Trap: A major takeaway is the regulatory hurdle. Currently, in many regions, taxes and levies are paid when buying energy but are not recouped when selling it back. Without regulatory reform to end this "double taxation," the economic potential of V2G is severely limited.
- Bidirectional Charging Value: Even though bidirectional chargers carry a premium (e.g., €4,000 for an 11kW Bidi vs. €3,594 for Unidirectional), the optimization consistently chose bidirectional chargers for all use cases, proving the extra investment pays for itself through energy trading.
Limitations and Future Work
The model currently assumes 100% efficiency for energy conversion and ignores battery degradation caused by extra V2G cycles. Furthermore, the "perfect foresight" optimizer does not account for real-world uncertainties in weather and rental returns. Future work will require more robust, stochastic control strategies and a deeper look into the legal frameworks required for grid ancillary market participation.
Summary updated