NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

DosePET: An Open-Source Dataset with 2100 Radiation Dose Maps for PET/CT

Eleftherios Tzanis, Antonios Tzortzakakis, Michail E. KlontzasarXiv 2026

TL;DR

Calculating how much radiation a patient’s organs absorb during a PET/CT scan requires computationally brutal physics simulations—meaning AI researchers haven't had enough training data to build fast, predictive alternatives. Enter DosePET: an open-source dataset of 2,100 patient-specific 3D radiation dose maps, complete with 117 anatomical organ masks per scan. The authors burned over two months of continuous compute time running Monte Carlo simulations so the rest of the medical AI community doesn't have to.

What Problem Does This Paper Address?

When you undergo a PET/CT scan, doctors inject a mildly radioactive tracer into your body to watch how your tissues behave. While invaluable for spotting diseases like cancer, this exposes healthy organs to radiation. Ideally, clinicians would use personalized internal dosimetry—calculating the exact radiation dose delivered to each specific organ based on your unique anatomy and tracer distribution—to optimize scan protocols and protect tissues.

The gold standard for calculating this is a Monte Carlo (MC) simulation, which tracks millions of virtual subatomic particles bouncing around a digital twin of the patient's body. The catch? It is painfully slow and computationally expensive. Deep learning could theoretically predict these dose maps in seconds, but training robust AI models requires massive, well-annotated datasets. Until now, the sheer computational burden of generating ground-truth MC maps has kept published AI studies stuck using tiny, proof-of-concept patient cohorts.

Methods

Instead of inventing a new algorithm, the authors built an automated, industrial-scale Python pipeline around established, gold-standard physics and segmentation tools to solve the data bottleneck.

The DosePET generation pipeline, from public PET/CT selection to Monte Carlo simulation and organ segmentation.

For each of the 2,100 examinations, the workflow executed the following steps:

  1. Building the Digital Phantom: The patient's CT scan (which shows tissue density in Hounsfield Units) was resampled to match the 3D voxel grid of the PET scan. These densities were converted into physical material compositions to serve as the virtual patient body.
  2. Defining the Source: Quantitative PET voxel values (measured in Becquerels per milliliter, or radioactive decays per second) were converted into total activity per voxel to map out where the radiation was coming from.
  3. Simulating Physics: Using GATE (v9.4)—a specialized wrapper around the CERN-developed Geant4 physics engine—the team simulated $10^7$ primary particle histories per scan, tracking electromagnetic radiation transport and radioactive decay (emstandard_opt4 physics list) to score absorbed dose in Grays (Gy).
  4. Anatomical Mapping: In parallel, they ran TotalSegmentator on the CT scans to automatically carve out 117 distinct binary organ and tissue masks, using them to extract regional dose reports.

Datasets

DosePET is the newly introduced open-source dataset (hosted on Hugging Face), derived by running secondary simulations on two existing, publicly available whole-body PET/CT repositories:

  • ENHANCE.PET: Contributed 1,503 [$^{18}\text{F}$]FDG scans covering malignant, inflammatory, and healthy control cases (180 scans from the original 1,683 were excluded because they lacked quantitative activity units).
  • PSMA-PET-CT-Lesions: Contributed 597 prostate cancer scans across 378 patients, split between two tracers: 369 [$^{18}\text{F}$]PSMA-1007 and 228 [$^{68}\text{Ga}$]Ga-PSMA-11 examinations.

In total, the data spans five institutions and seven different scanner models, offering vital diversity for training generalizable AI.

Key Insights and Ideas

  • Compute-as-a-Public-Good: By absorbing 1,542.4 hours (~64 days) of heavy simulation time on high-end hardware (Intel Core i9-14900, 128 GB RAM, RTX 5090), the authors removed the primary barrier to entry for AI researchers in nuclear medicine.
  • Flexible Physics Units: Rather than locking users into one metric, the authors provide raw 3D maps integrated from scan time to infinity alongside Python tools to mathematically convert them into scan-time dose-rate maps or dose-per-decay maps, accommodating different modeling paradigms.
  • Built for AI Agents: Uniquely for a medical dataset, DosePET includes a SKILL.md file—an explicit instruction set designed to guide autonomous coding/research AI agents in downloading the data, pairing it with the original source PET/CT images, and prepping it for machine learning pipelines.

Key Results

Because this is a dataset resource paper rather than a model-benchmarking paper, the primary results are the scale and completeness of the generated artifacts:

  • 2,100 complete study folders produced across three major radiopharmaceuticals.
  • Every folder packages a compressed NIfTI 3D absorbed-dose map, 117 binary organ/tissue masks, JSON metadata/configuration sidecars, and a CSV report detailing organ-level mean absorbed doses, spatial standard deviations, scan-time dose rates, and target masses.
Example CT-dose overlays across the three radiopharmaceuticals showing high-dose accumulation in organs like the bladder, kidneys, and liver.
(Note: While the text mentions that Table 1 and Table 2 summarize participant characteristics and median organ doses, those specific numerical tables are omitted from the main manuscript pages).

Limitations and Future Work

  • Static Biokinetics Assumption: A key physical limitation noted in the pipeline is that the 3D maps integrate radiation dose from scan time to infinity assuming physical radioactive decay alone and an unchanged spatial distribution. In reality, living bodies biologically clear and redistribute tracers over time (biological half-life), which single-timepoint PET scans cannot directly capture.
  • AI-Generated Contours: The 117 organ masks are generated by an AI tool (TotalSegmentator) rather than manual radiologist delineation, though users can apply their own manual contours (like the tumor masks from the source PSMA dataset) to the dose maps.
  • Future Directions: The authors envision DosePET serving as the foundational bedrock for training rapid 3D dose-prediction neural networks, extracting radiomic features, fine-tuning nuclear medicine foundation models, and powering automated, agentic medical AI workflows.

Summary updated

BibTeX
@misc{tzanis2026dosepet,
  author = {Eleftherios Tzanis and Antonios Tzortzakakis and Michail E. Klontzas},
  title = {{DosePET: An Open-Source Dataset with 2100 Radiation Dose Maps for PET/CT}},
  year = {2026},
  eprint = {2611.34008},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.34008},
}
Figure