Do Not Let the Prior Heal the Anomaly: Selective Anchoring for Detection from Incomplete Measurements

Nicolas Tricard, Stefan Brandstätter, Jason Chen, Zituo Chen, Linzheng Wang, Georg Langs, Sili DengarXiv 2026

TL;DR

When generative AI reconstructs medical scans from incomplete data, its bias toward "normal" anatomy can accidentally erase the very tumors doctors are looking for. This paper introduces selective anchoring, a technique that locks down reliably measured signals—along with their honest sensor noise—so generative priors can fill in missing anatomical details without "healing" away real abnormalities.

What Problem Does This Paper Address?

To reduce radiation exposure or cut down long MRI scan times, modern medical imaging often collects incomplete measurements. Turning sparse data into a clear picture requires solving an underdetermined puzzle, and generative models (like diffusion and flow matching) are great at filling in the blanks.

Here is the catch: those models are trained predominantly on healthy anatomy. Confronted with faint evidence of a rare lesion, a generative prior tends to smooth it over into healthy-looking tissue, causing missed diagnoses. Conversely, existing methods that force every generated sample to strictly match the raw, noisy measurements create an artificial consensus across samples. Downstream statistical tests mistake that consensus for high certainty, turning minor measurement noise in healthy tissue into false alarms.

Selective anchoring preserves a brain tumor missed by an unanchored model and eliminates a false alarm on a healthy scan.

Methods

The authors observe that incomplete measurements do not constrain an image uniformly: some mathematical directions (singular vectors of the imaging physics operator) are measured with crisp precision, while others are noisy or completely unobserved.

Selective anchoring splits the reconstruction space into two parts by comparing sensor noise to natural anatomical variability (via an information ratio cutoff, $\kappa$):

  1. Held components: Directions where sensor readings are reliable are locked ("anchored") directly to the measurements. The generative prior is barred from altering them.
  2. Free components: Weakly measured or unmeasured directions are handed over to the generative model to reconstruct.

To prevent false alarms, the method tracks sensor uncertainty in the held components in one of two ways: deterministic anchoring fixes the held values and adds their known physical noise variance analytically during anomaly testing, while stochastic anchoring injects independent noise perturbations into each sample's target so the ensemble naturally reflects acquisition uncertainty.

Overview of selective anchoring implemented as a wrapper for pretrained samplers and as the standalone AnchoredFM model.

The authors implement this in two ways:

  • A training-free wrapper that slots into eight existing diffusion and flow-based samplers, overriding their clean-image predictions at each step to protect the held subspace.
  • AnchoredFM, a custom flow-matching model trained to evolve only the unconstrained free components, making inference remarkably fast.

Datasets

All experiments use simulated acquisitions trained on healthy images and tested on real or synthetic pathologies—without introducing new public benchmarks:

  • Sparse-view CT: LoDoPaB-CT chest slices (64 parallel-beam views) with twelve types of synthetically inserted lesions.
  • Accelerated Brain MRI: BraTS FLAIR scans from the Medical Segmentation Decathlon (32 or 64 of 256 k-space lines), featuring real tumors with expert masks.
  • Photoacoustic Tomography: VICTRE breast phantoms (64 ring detectors) using paired healthy and lesion-bearing digital twins.

Key Insights and Ideas

  • Prettier pictures can be worse for diagnosis: Whole-image visual quality metrics (like SSIM) actually drop under anchoring—from 0.950 to 0.804 in MRI—because anchoring refuses to let the AI denoise the protected measurements. Yet tumor detection jumps dramatically. Visual plausibility and clinical evidence preservation are distinct goals.
  • Prior-free statistical guarantees: Regardless of how flawed or biased the generative model is on the unmeasured parts, the protected components remain mathematically unbiased and achieve exact nominal uncertainty coverage.
  • Uniformity across diverse samplers: Different off-the-shelf generative samplers normally exhibit wildly different uncertainty calibration and detection rates. Anchoring brings them all onto a level, reliable playing field.

Key Results

  • MRI Tumor Detection: Using a practical healthy reference estimated directly from the scan (via checkerboard inpainting) across eight sampler pairs, deterministic anchoring boosts mean AUROC from 78.4% to 84.6% and sensitivity (at 0.25 false positives/slice) from 38.8% to 47.5%, improving detection across all four tumor-size groups. At validation-frozen thresholds, sensitivity more than doubles from 20.2% to 44.1%.
  • Boosting Reference-Free Detectors: Paired with an existing anomaly detector (KLIP), anchoring pushes MRI AUROC from 83.7% to 93.7%.
  • Uncertainty Calibration: In 64-line MRI, nominal 90% ensemble intervals cover only 68.3% of held coefficients on average without anchoring (dropping as low as 32.0% for DDNM), whereas stochastic anchoring brings average coverage right to 90.0%.
  • Real-Time Speed: On a single H100 GPU (128-grid CT), AnchoredFM generates a 16-sample ensemble in 5.9 ms (a single network evaluation per sample)—running 74× faster than full-budget anchored flow matching while maintaining competitive lesion contrast and error rates.

Limitations and Future Work

  • Unprotected subspaces: Anchoring only shields well-measured directions. If a tiny lesion hides mostly in unmeasured directions, the prior can still erase it, and model overconfidence in free directions can still trigger false alarms.
  • Exact physics required: The guarantees rely on knowing the exact linear imaging operator and Gaussian noise level. Tests show that underestimating CT noise by 20% inflates false alarms (up to 18.2%), and large operator errors degrade photoacoustic reconstructions.
  • Simulated data: All measurements are simulated—including generating MRI k-space from magnitude images rather than raw multi-coil complex data (an "implicit data crime"). Validating selective anchoring on raw clinical scanner hardware remains an open next step.

Summary updated