NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Discrimination of malignant and benign breast masses using automatic segmentation and features extracted from dynamic contrast‑enhanced and diffusion‑weighted MRI

Xinhua Jiang, Fei Xie, Lizhi Liu, Yanxia Peng, Hongmin Cai, Li LiOncology 2018

Abstract

Magnetic resonance imaging (MRI) is highly sensitive for breast cancer detection but often lacks specificity, leading to unnecessary biopsies. This study investigates a multi-modal computer-aided diagnosis (CAD) approach that integrates morphology, texture, and kinetic features with diffusion-weighted imaging (DWI). Using a semi-automated segmentation pipeline and a novel Difference-Weighted Local Hyperplane (DWLH) classifier, the researchers achieved a diagnostic accuracy of 90% in distinguishing malignant from benign masses.

Introduction

While MRI is a cornerstone of breast cancer screening, its low specificity frequently results in false positives. Radiologists traditionally rely on subjective assessments of lesion shape and contrast enhancement kinetics. This research aims to provide a more objective, quantitative framework by combining these traditional metrics with texture analysis and Apparent Diffusion Coefficient (ADC) values from DWI.

Methodology: A Semi-Automated Pipeline

The researchers developed a three-stage pipeline to analyze breast lesions:

  1. Segmentation: Lesions were isolated using a two-step process. Initial boundaries were established via Fuzzy C-Means (FCM) clustering, followed by refinement using a Gradient Vector Flow (GVF) snake algorithm to precisely match the lesion edges.
  2. Feature Extraction: 25 quantitative features were extracted, including 11 morphological features (e.g., spiculation, circularity), 13 texture features (via Gray Level Co-occurrence Matrices), Signal Enhancement Ratio (SER) for kinetics, and ADC for water diffusion.
  3. Classification: A Difference-Weighted Local Hyperplane (DWLH) classifier was employed to build robust local decision surfaces, improving performance over standard nearest-neighbor algorithms.
The segmentation process: (A) Original MRI with region of interest, (B) initial segmentation using FCM, and (C) refined boundary using the GVF snake algorithm.

Results and Discussion

The study analyzed 275 lesions from 205 patients, with ground truth confirmed by histopathology or long-term clinical follow-up.

The Role of Diffusion and Kinetics

Malignant lesions exhibited significantly lower mean ADC values ($1.16 \times 10^{-3} \text{ mm}^2/\text{sec}$) than benign ones ($1.68 \times 10^{-3} \text{ mm}^2/\text{sec}$), reflecting the restricted water movement in dense cancerous tissue. While kinetics (SER) remained a strong individual predictor with 87.6% accuracy, the integration of all parameters proved superior.

Performance Metrics

The combined model significantly outperformed single-modality assessments:

Feature Set Sensitivity Specificity Accuracy AUC
Morphology Only 0.57 0.78 0.70 0.68
Kinetics Only 0.79 0.89 0.85 0.84
ADC Only 0.78 0.90 0.84 0.83
Combined Model 0.85 0.94 0.90 0.90

The addition of an ADC threshold ($1.37 \times 10^{-3} \text{ mm}^2/\text{sec}$) was critical in reaching the 90% accuracy threshold.

Conclusion

Incorporating morphology, texture, kinetics, and diffusion data into a multivariate diagnostic model significantly improves the discriminatory power of breast MRI. While currently limited to 2D analysis of mass-like lesions, this quantitative approach offers a promising path toward reducing false positives and improving clinical decision-making in breast cancer care.

Summary updated

BibTeX
@inproceedings{jiang2018discrimination,
  author = {Xinhua Jiang and Fei Xie and Lizhi Liu and Yanxia Peng and Hongmin Cai and Li Li},
  title = {{Discrimination of malignant and benign breast masses using automatic segmentation and features extracted from dynamic contrast‑enhanced and diffusion‑weighted MRI}},
  booktitle = {Oncology},
  year = {2018},
  doi = {10.3892/ol.2018.8805},
}
Figure