TL;DR
Researchers have successfully measured a significantly lower concentration of the radioactive isotope <sup>39</sup>Ar in argon sourced from underground natural gas reserves compared to atmospheric argon. This discovery is crucial for building larger, more sensitive detectors for WIMP dark matter searches, as <sup>39</sup>Ar is a major background noise source.
What Problem Does This Paper Address?
The nature of dark matter remains one of the biggest mysteries in physics. A leading candidate for dark matter particles is the Weakly Interacting Massive Particle (WIMP). Detecting WIMPs requires highly sensitive experiments that can distinguish rare WIMP-nucleus interactions from background radiation. Noble gases like argon are excellent candidates for WIMP detectors due to their scintillation and ionization properties, which allow for good discrimination between nuclear recoils (potential WIMP signals) and beta/gamma events (background). However, atmospheric argon contains a significant amount of the radioactive isotope <sup>39</sup>Ar (half-life of 269 years), which decays via beta emission and poses a major background challenge for these detectors. To build larger, more sensitive WIMP detectors, a source of argon with a much lower <sup>39</sup>Ar concentration than atmospheric argon is needed.
Methods
The researchers employed a two-pronged approach:
- Argon Purification: A novel Pressure Swing Adsorption (PSA) plant developed at Princeton was used to process crude helium from the US National Helium Reserve. This plant effectively removed strongly adsorbing components like N<sub>2</sub>, CO<sub>2</sub>, H<sub>2</sub>S, CH<sub>4</sub>, and heavier hydrocarbons, concentrating argon and helium. The system was designed to be leak-tight to minimize atmospheric contamination.
- <sup>39</sup>Ar Measurement: The purified argon was then measured for its <sup>39</sup>Ar content using a low-background proportional counter system at the Underground Low Level Counting Laboratory in Bern, Switzerland. This setup utilizes a 100 cm³ proportional counter filled with the argon sample at 10 bars, surrounded by a thick lead shield and an anti-coincidence proportional detector to minimize background noise. Measurements were performed using three samples: the underground argon, a reference <sup>39</sup>Ar-depleted argon (processed via differential thermal diffusion), and standard atmospheric argon.
Datasets
The primary "dataset" in this paper is the argon gas itself, sourced from:
- US National Helium Reserve: Located in Cliffside Storage Facility, Amarillo, TX. Samples were collected from the Helium Conservation Pipeline at the Kansas Refined Helium plant. This represents a novel source of underground argon.
- <sup>39</sup>Ar-depleted reference argon: Provided by Monsanto Co. (Miamisburg, OH), processed via differential thermal diffusion. This served as a crucial benchmark for background measurements.
- Atmospheric argon: Used as a standard reference for comparison.
Key Insights and Ideas
- Underground Argon as a Low-Background Source: The most significant insight is that argon trapped in underground natural gas reservoirs has a substantially lower <sup>39</sup>Ar concentration than atmospheric argon. This is because the production of <sup>39</sup>Ar (primarily via cosmic ray interactions) is greatly suppressed underground.
- Feasibility of Large-Scale WIMP Detectors: The discovery demonstrates the practical possibility of obtaining sufficient quantities of low-<sup>39</sup>Ar argon to construct multi-ton detectors, which are necessary to achieve the sensitivity required for WIMP detection.
- <sup>39</sup>Ar Production Mechanisms: The paper touches upon how <sup>39</sup>Ar is produced in subsurface environments, primarily through neutron reactions on potassium (<sup>39</sup>K(n,p)<sup>39</sup>Ar), and how local U and Th concentrations can enhance this activity in certain geological formations.
Key Results
- The argon sample from the US National Helium Reserve was found to have a <sup>39</sup>Ar/Ar ratio of <4×10<sup>-17</sup> (at 84.1% confidence level).
- This ratio is less than 5% of the value found in atmospheric argon (<sup>39</sup>Ar/Ar ≈ 8×10<sup>-16</sup>).
- The depletion factor for the underground argon is ≥20 at 84.1% C.L.
- The US National Helium Reserve is estimated to contain 1000 tons of argon, indicating a substantial potential source.
Limitations and Future Work
- Measurement Sensitivity: The current measurement of <sup>39</sup>Ar in underground argon is an upper limit based on the background of the proportional counting system. While groundbreaking, more sensitive techniques are needed for precise determination.
- Future Techniques: The authors suggest exploring Accelerator Mass Spectrometry (AMS) and <sup>39</sup>Ar-decay counting in liquid argon detectors for more accurate measurements. AMS is already capable of measuring <sup>39</sup>Ar/Ar ratios around 5% of atmospheric levels, with potential for further improvement.
- Exploration of Other Sources: This work is part of a broader program to explore other underground argon sources.
- Detector Development: The findings pave the way for developing new, potentially more sensitive, low-background, multi-ton argon detectors for WIMP searches, aiming for sensitivities of 10<sup>-46</sup> cm² or smaller for the WIMP-nucleon cross section.
- Neutrino Physics Applications: The availability of low-<sup>39</sup>Ar argon also has implications for neutrino physics, enabling studies of neutrino-nucleus coherent scattering and the development of small, portable neutrino detectors for reactor monitoring and neutron detectors for port security.
Summary updated