Diffusion-weighted Imaging Voxelwise-matched Analyses of Lung Cancer at 3.0-T PET/MRI: Reverse Phase Encoding Approach for Echo-planar Imaging Distortion Correction

Florent L. Besson, Brice Fernandez, Sylvain Faure, Olaf Mercier, Andrei Seferian, Elise M. Blanchet, Xavier Mignard, Ahmed Chetouani, Sophie Bulifon, Sacha Mussot, Florence Parent, Fahd Bouderraoui, David Montani, Délphine Mitilian, Élie Fadel, Maria‐Rosa Ghigna, Hamza Cherkaoui, Claude Comtat, Vincent Lebon, Emmanuel DurandRadiology 2020 · DOI

Abstract

Background PET/MRI has drawn increasing interest in thoracic oncology due to the simultaneous acquisition of PET and MRI data. Geometric distortions related to diffusion-weighted imaging (DWI) limit the evaluation of voxelwise multimodal analyses. Purpose To assess the effectiveness of reverse phase encoding in correcting DWI geometric distortion for multimodal PET/MRI voxelwise lung tumor analyses. Materials and Methods In this prospective study, reverse phase encoding method was implemented with 3.0-T PET/MRI to correct geometric distortions related to DWI. The method was validated in dedicated phantom and then applied to 12 consecutive patients (mean age, 66 years ± 13 [standard deviation]; 10 men) suspected of having lung cancer who underwent fluorodeoxyglucose PET/MRI between October 2018 and April 2019. The effects on DWI-related image matching and apparent diffusion coefficient (ADC) regional map computation were assessed. Consequences on multimodal PET/MRI voxelwise lung tumor analyses were evaluated. Spearman correlation coefficients (<i>r</i><sub>s</sub>) between the standardized uptake value (SUV) and ADC data corrected for distortion were computed from optimal realigned DWI PET data, along with bootstrap confidence intervals. Results Phantom results showed that in highly distorted areas, correcting the distortion significantly reduced the mean error against the ground truth (-25% ± 10.6 to -18.4% ± 12.6; <i>P</i> < .001) and the number of voxels with more than 20% error (from 85.3% to 31.4%). In the 12 patients, the coregistration of multimodal PET/MRI tumor data was improved by using the reverse phase encoding method (0.4%-44%). In all tumors, voxelwise correlations (<i>r</i><sub>s</sub>) between ADC and SUV revealed null or weak monotonic relationships (mean <i>r</i><sub>s</sub> of 0.016 ± 0.24 with none above 0.5). Conclusion Reverse phase encoding is a simple-to-implement method for improved diffusion-weighted multimodal PET/MRI voxelwise-matched analyses in lung cancer. © RSNA, 2020 <i>Online supplemental material is available for this article.</i> See also the editorial by Colletti in this issue.
BibTeX
@inproceedings{besson2020diffusion,
  author = {Florent L. Besson and Brice Fernandez and Sylvain Faure and Olaf Mercier and Andrei Seferian and Elise M. Blanchet and Xavier Mignard and Ahmed Chetouani and Sophie Bulifon and Sacha Mussot and Florence Parent and Fahd Bouderraoui and David Montani and Délphine Mitilian and Élie Fadel and Maria‐Rosa Ghigna and Hamza Cherkaoui and Claude Comtat and Vincent Lebon and Emmanuel Durand},
  title = {{Diffusion-weighted Imaging Voxelwise-matched Analyses of Lung Cancer at 3.0-T PET/MRI: Reverse Phase Encoding Approach for Echo-planar Imaging Distortion Correction}},
  booktitle = {Radiology},
  year = {2020},
  doi = {10.1148/radiol.2020192013},
}

Loading related content...

Figure