Dielectric Property Measurements on Large Alumina Vacuum Seals Used on Fermilab Accelerator RF Cavities
Lists
Only you see this
Abstract
The RF window vacuum seals on the 400-GeV Fermilab accelerating RF cavities are very large circular cylinders of alumina. The cavities were first installed with seals of 94% purity Al2O3. Several of these seals failed in high-power operation due to dielectric heating. Higher purity ceramics (99.5% Al2O3) have been obtained and are now being installed. The complex permitivity of both types of ceramic has been measured in a TM010 mode test cavity ten-inches high and eight feet in diameter. Frequency shift and Q shift data have been analyzed by perturbation analysis and by computer programs. Results confirm that the higher purity ceramics have a loss tangent a factor of five better than the original seals. Some high-power operational test results are also presented.
BibTeX
@article{bridges1975dielectric,
author = {J. Bridges and D.E. Johnson and Jim E. Griffin},
title = {{Dielectric Property Measurements on Large Alumina Vacuum Seals Used on Fermilab Accelerator RF Cavities}},
journal = {IEEE Transactions on Nuclear Science},
year = {1975},
doi = {10.1109/tns.1975.4327870},
}Loading related content...