DiCT: Teaching X-ray Vision-Language Models to Reason via Imagining CT

Zhenghao Lu, Xiaotian Zhang, Songtao Jiang, Yiqun Lin, Siming Fu, Hualiang Wang, Zuozhu LiuarXiv 2026

TL;DR

Reading a 2D chest X-ray is like interpreting shadows on a wall—vital 3D depth gets squashed, making spatial reasoning difficult for AI models. Instead of burning massive compute to reconstruct a full 3D CT scan from an X-ray at runtime, Dreaming in CT (DiCT) teaches a lightweight X-ray Vision-Language Model (VLM) to imagine the 3D anatomy in text. The result is CT-level diagnostic reasoning directly from standard 2D X-rays, running nearly 13× faster than reconstruction pipelines.

Figure 1. Overview and performance comparison of DiCT. The upper panel illustrates how DiCT transfers CT-informed reasoning from a CT teacher to an X-ray student for X-ray-only inference without CT reconstruction. The lower panel compares model per- formance and inference cost across methods. Mean score is the arithmetic mean accuracy of Abnormality Identification and Lon- gitudinal Diagnosis on 3D-RAD. 12.77× denotes the reduction in inference FLOPs over the TF-PRDiT + ClinFusion-8B-SFT re- construction pipeline.

What Problem Does This Paper Address?

In hospitals, X-rays are fast, cheap, and low-radiation, while CT scans are rich 3D volumes that take longer, cost more, and deliver higher radiation doses. When a Vision-Language Model looks at a 2D X-ray, organs overlap and depth disappears, making it tough to pinpoint where an abnormality actually sits in 3D space.

Until now, if you wanted 3D reasoning from a 2D X-ray, the standard workaround was a two-step pipeline: use a generative model to hallucinate a 3D CT volume from the X-ray, and then feed that synthetic volume into a 3D VLM. That works, sort of—but it’s computationally heavy and prone to cascading reconstruction errors.

Why not just distill knowledge from a CT-reading "teacher" model into an X-ray-reading "student" model? Because of information asymmetry. The teacher sees rich 3D slices the student physically cannot see in a flat X-ray. Naive distillation forces the student to claim it "sees" 3D features in a 2D shadow, corrupting its grounding in visual reality.

Methods

DiCT solves this asymmetry by separating what the model sees from what the model imagines, rolled out across three progressive stages:

Figure 2. Method overview. DiCT comprises three complementary stages: (1) instruct the dreamer initializes X-ray and CT-oriented reasoning through structured SFT. (2) visualize the dream applies masked CT-guided OPD from the CT teacher to the X-ray student’s own responses. (3) manifest the dream adapts the distilled policy to real clinical X-rays through clinical GRPO with task rewards and a KL anchor. DiCT enables X-ray-only inference without CT reconstruction.
  1. Instruct the Dreamer (Structured SFT): Standard supervised fine-tuning, but with a strict three-part output template: [thinking with X-ray], [thinking with CT], and [Final Answer]. This builds a clean interface separating 2D planar observations from 3D spatial reasoning.
  2. Visualize the Dream (Selective CT-Guided On-Policy Distillation): This is the core novelty. Using On-Policy Distillation (OPD)—where the student generates its own reasoning rollouts and the frozen CT teacher grades them token-by-token using the patient's actual paired 3D CT—the authors apply structured masking. Teacher feedback is only applied to the [thinking with CT] and [Final Answer] tokens. Meanwhile, [thinking with X-ray] tokens are anchored to the Stage 1 model via KL-divergence so the student stays honest about what’s actually visible in 2D.
  3. Manifest the Dream (Clinical GRPO): Stages 1 and 2 rely on synthetic X-rays derived from CTs. To bridge the gap to real hospital X-rays, the model undergoes Group-Relative Policy Optimization (GRPO)—a reinforcement learning technique—using task-specific rewards (like exponential accuracy rewards for millimeter measurements) and a KL anchor so it doesn't forget its 3D "dreaming" skills.

Datasets

  • 3D-RAD (paired with CT-RATE & DRR-RATE): Used for Stages 1 & 2 and evaluation. Because true simultaneous X-ray/CT pairs are rare, the authors pair 3D CTs (CT-RATE) with Digitally Reconstructed Radiographs (DRRs—synthetic 2D X-rays projected from CTs). Notably, they reformulate 3D-RAD’s heavily imbalanced binary abnormality task (82% negative) into a balanced four-choice Abnormality Identification benchmark (4,223 questions) alongside 11,788 test questions across five tasks.
  • ReXVQA: Real clinical chest X-rays used to adapt the model in Stage 3 (via open-ended length measurement questions) and test out-of-domain generalization on native Abnormality Identification questions.

Key Insights and Ideas

  • Don't force blind students to lie: Masking out the 2D observation tokens during cross-modal distillation is crucial. Without Stage 1's structured split and selective masking, OPD alone drops accuracy by over 5 percentage points because 3D teacher signals bleed into 2D visual descriptions.
  • Self-correcting internal monologues: Qualitative examples show the model looking at an X-ray, initially guessing "consolidation" or "40 mm mass" in its [thinking with X-ray] block, and then actively revising its own answer to "pleural effusion" or "30 mm" once it switches to [thinking with CT] reasoning.
  • Synthetic 3D dreams generalize to real X-rays zero-shot: Even before Stage 3 touches a single real X-ray, Stage 2's OPD checkpoint jumps from 45.64% to 66.90% accuracy (on Qwen3-VL-4B) on real clinical ReXVQA radiographs.

Key Results

Tested on two 4B-parameter VLM backbones (Qwen3-VL-4B and Hulu-4B):

  • Beats 3D Reconstruction at a Fraction of the Cost: On 3D-RAD Abnormality Identification, Hulu-4B-DiCT hits 47.53% accuracy, beating the heavy TF-PRDiT + CT Teacher reconstruction pipeline (45.87%) while slashing inference compute by 12.77× (10.39 vs. 132.66 TFLOPs/question).
  • Outperforms Standard 2D RL: Compared to standard X-ray SFT → GRPO pipelines without CT guidance, DiCT boosts Abnormality Identification from 41.37% to 47.53% (Hulu-4B) and reduces Measurement Mean Absolute Error (MAE) from 14.22 mm down to 9.86 mm.
  • Real Clinical X-ray Gains: On ReXVQA, DiCT reaches 83.65% (Hulu-4B) and 67.74% (Qwen3-VL-4B) on Abnormality Identification, handily beating conventional 2D training (75.11% and 35.42%, respectively). Token Activation Maps also confirm the model attends much more tightly to true anatomical targets.

Limitations and Future Work

  • Pixel-level geometry still favors 3D: Explicit CT reconstruction pipelines still edge out DiCT on raw millimeter measurement precision (8.92 mm vs. 9.86 mm MAE on 3D-RAD) and certain open-ended descriptions, showing that "imagined" 3D doesn't fully replace voxel-exact geometry. Also, on real X-ray measurements, DiCT is competitive with—rather than consistently superior to—standard 2D RL.
  • Domain scope: Training relies on synthetic DRRs for paired supervision before clinical adaptation. Future work aims to expand CT-informed reasoning transfer to broader anatomical regions, clinical settings, and diverse radiological tasks.

Summary updated

Abstract

Diagnosing with X-rays often requires reasoning about the 3D locations of abnormalities and their spatial relationships to surrounding anatomical structures, yet such reasoning remains challenging due to the loss of spatial information in 2D projections. To address this challenge, we propose Dreaming in CT (DiCT), a three-stage progressive CT-to-X-ray reasoning transfer framework that leverages a CT vision-language model (VLM) to guide an X-ray VLM. Through this CT-guided transfer, the student acquires CT-informed 3D reasoning capabilities, enabling it to reason directly from 2D X-rays without explicit CT reconstruction at inference time. The framework begins with instruct the dreamer, which equips the X-ray student with initial CT-oriented reasoning capabilities and establishes a structured interface that distinguishes X-ray observations from CT imagination. Building on this structure, visualize the dream introduces CT-guided on-policy distillation (OPD), where the CT teacher selectively guides the X-ray student's reasoning trajectories to transfer 3D anatomical knowledge. Finally, manifest the dream adapts the acquired reasoning capabilities from digitally reconstructed radiographs (DRRs) to real clinical X-rays. Experiments across two VLM backbones on 3D-RAD and ReXVQA demonstrate DiCT's effectiveness across radiological reasoning tasks, achieving a 1.66 percentage point improvement over a CT reconstruction-based baseline on 3D-RAD Abnormality Identification with 12.77$\times$ lower inference computation. Our code is available at https://github.com/HongYep/DiCT.
BibTeX
@misc{lu2026dict,
  author = {Zhenghao Lu and Xiaotian Zhang and Songtao Jiang and Yiqun Lin and Siming Fu and Hualiang Wang and Zuozhu Liu},
  title = {{DiCT: Teaching X-ray Vision-Language Models to Reason via Imagining CT}},
  year = {2026},
  eprint = {2611.32344},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.32344},
}
Figure