TL;DR
This paper introduces a novel diaphragm-free fiber-optic Fabry-Perot (FP) gas pressure sensor designed for extreme high-temperature environments (up to 800°C). By cleverly integrating a Fiber Bragg Grating (FBG) for temperature compensation and a unique cavity structure, the sensor achieves accurate pressure measurements with minimal non-linearity, overcoming limitations of traditional diaphragm-based sensors.
What Problem Does This Paper Address?
Measuring gas pressure accurately in high-temperature environments is a significant challenge. Conventional pressure sensors often rely on diaphragms that can deform plastically or fail under extreme heat, limiting their operational range and reliability. Furthermore, temperature fluctuations can significantly affect pressure readings, necessitating robust temperature compensation. Existing fiber-optic pressure sensors, while offering advantages like electromagnetic immunity, still face issues with material thermal expansion and elastic modulus changes at high temperatures, impacting their accuracy. This paper aims to address these limitations by developing a diaphragm-free fiber-optic sensor that is inherently more robust at high temperatures and incorporates an effective temperature decoupling mechanism.
Methods
The core of the sensor is a Fabry-Perot (FP) interferometer fabricated by inserting a Fiber Bragg Grating (FBG) and a hollow silica tube (HST) into a silica casing. The FP cavity is formed between the end of a single-mode fiber (SMF) and the HST. The pressure of the gas influences the density within the FP cavity, which in turn alters the interference spectrum.
A key innovation is the temperature decoupling method. This involves:
- In-situ Temperature Measurement: An FBG is inscribed within the SMF. The FBG's center wavelength is highly sensitive to temperature, allowing for precise, real-time temperature monitoring.
- Temperature Compensation Structure: A specific ratio (9:1) of distances between structural elements (L3 and L1) is used to mitigate the effects of thermal expansion between the SMF and the silica casing, reducing zero drift.
- Sensitivity Calibration: The sensor is calibrated at specific temperatures, and the relationship between temperature and pressure sensitivity is determined.
- Pressure Calculation: By combining the FBG's temperature reading with the calibrated sensitivity, the actual gas pressure can be accurately calculated, effectively decoupling it from temperature variations.
The fabrication process involves cleaving and fusing the SMF, silica casing, and HST. To improve interference spectrum quality, the outer reflection surface (S3) of the HST is etched with hydrofluoric acid to minimize its contribution to the interference.
Datasets
Not discussed in the paper. The experiments were conducted using a custom-built experimental setup with a pressure tank, temperature control cabinet, and gas cylinder, and data was collected using a spectrum analyzer.
Key Insights and Ideas
- Diaphragm-Free Design for High Temperatures: Eliminating the diaphragm is crucial for high-temperature applications, preventing plastic deformation and enabling operation up to 800°C.
- Dual-Function FBG: The FBG serves a dual purpose: acting as a reference for temperature measurement and contributing to the overall interference spectrum.
- Effective Temperature Decoupling: The proposed method significantly improves accuracy by accounting for temperature-induced changes in sensitivity, a common issue in high-temperature sensors.
- Simple and Low-Cost Fabrication: The use of standard fiber optic components and a straightforward fusion process makes the sensor potentially cost-effective for industrial deployment.
- Linearity and Stability: The sensor demonstrates good linearity over the tested pressure range and excellent stability even at extreme temperatures.
Key Results
- Pressure Sensitivity: 4.28 nm/MPa at 20°C, decreasing to 1.15 nm/MPa at 800°C.
- Temperature Sensitivity: 14.8 pm/°C within the 20-800°C range.
- Linear Pressure Response: High linearity over the range of 0.1–0.7 MPa.
- Non-linearity: Less than 1.5% at different temperatures after applying the temperature decoupling method.
- Operating Temperature: Verified up to 800°C, with potential for higher temperatures.
- Stability: Demonstrated good stability with slight variations in wavelength response over 100 minutes at 800°C.
- Accuracy: Calculated values showed good agreement with actual values, with maximum errors of 5.3, 7.6, and 8.1 KPa at 20, 400, and 800°C, respectively. Non-linearity errors were below 1.34%.
Limitations and Future Work
- Gas Mixture Sensitivity: The sensor's measurement is based on gas density, which is dependent on the refractive index of the gas. This means the sensor is best suited for single-component gases or mixed-component gases with invariant compositions. For changing gas mixtures, recalibration or a more complex sensing mechanism would be required.
- Sensitivity Variation: The paper notes that the deviation of calculated values from actual values increases with temperature, potentially due to fitting deviations in sensitivity.
- Future Work: The authors plan to conduct a more thorough study of the fitting method to further improve the accuracy of the temperature decoupling method. They also aim to explore applications in monitoring high-temperature steam in power stations and other industrial environments.
Summary updated