Deviation analysis of rotational inertia measurement based on torsion bar method

Xinming Zhang, De Min Wang, Jun Ye Li, Chun Min Shang, Jia Xin Xiong, Hong Cai XieVibroengineering 2018

Abstract

The measurement of the moment of inertia is critical across numerous fields, including aerospace, automotive engineering, and precision machinery, as it directly influences the reliability and dynamic performance of equipment. This paper analyzes the principles of the torsion bar test method to evaluate the factors affecting measurement precision. By examining measurement errors, position errors, and damping effects, this study demonstrates that the torsion bar method can achieve a measurement accuracy of 0.1%.

Introduction

In high-precision engineering, theoretical calculations of rotational inertia are often insufficient due to the irregular geometries and heterogeneous material compositions of real-world components. Experimental verification is therefore essential. The torsion bar method is a widely adopted technique for these measurements. However, achieving high accuracy requires a rigorous understanding of the potential sources of deviation, such as sensor timing resolution, mechanical misalignment, and environmental damping.

Methodology: The Torsion Bar System

The torsion bar method operates on the principle of harmonic oscillation. A test object is mounted on a tooling swing frame supported by a torsion bar. The system is subjected to a momentary torque, causing it to oscillate at a frequency determined by the total moment of inertia and the torsion coefficient of the bar.

Schematic of the torsion bar measurement system showing the rotating shaft, tooling swing frame, and axial centroid.

The measurement process involves two distinct phases:

  1. Empty State: The oscillation period ($T_0$) of the empty test fixture is measured.
  2. Loaded State: The oscillation period ($T$) is measured with the test object installed.

By comparing these periods, the moment of inertia of the object ($J_d$) can be isolated using the known torsion coefficient ($K$) of the spring system.

Deviation Analysis

Measurement and Timing Error

A critical finding of this analysis is the relationship between timing precision and inertia accuracy. The authors derive a "2x Error Rule," where the relative error of the moment of inertia ($\mu_{Jd}$) is approximately twice the relative error of the time measurement ($\mu_T$). This underscores the necessity of high-frequency sensors; for instance, using photoelectric sensors with a 1000 Hz response frequency (1ms resolution) is vital for minimizing the "error budget."

Position and Alignment Error

Mechanical misalignment is a significant source of systematic error. This occurs when the object's center of mass is not perfectly collinear with the machine's rotating shaft, leading to eccentricity ($e$) and tilt ($\alpha$).

Diagram illustrating position error due to eccentricity (e) between the symmetric axis and the actual rotating shaft.

Using the parallel axis theorem, the study quantifies these tolerances. It concludes that if the shaft inclination (tilt) is maintained below 0.5°, the resulting error remains negligible (below $2 \times 10^{-3}$). This provides a clear operational threshold for laboratory setups.

Damping Effects

While air resistance and internal friction (damping) are often feared to degrade pendulum data, the study shows these effects are manageable. Even with significant amplitude attenuation—where the oscillation decays to 70% of its original magnitude—the resulting error in the period calculation is only 0.08%. In controlled laboratory environments, the impact is typically much lower.

Conclusion

Through rigorous mathematical modeling of timing, alignment, and damping, this research confirms that the torsion bar method is a highly robust technique for inertia measurement. By adhering to specific mechanical tolerances (such as tilt < 0.5°) and utilizing high-resolution timing hardware, engineers can reliably achieve a total measurement accuracy of 0.1%. This level of precision is sufficient for the most demanding applications in aerospace and precision motor design.

Summary updated

BibTeX
@inproceedings{zhang2018deviation,
  author = {Xinming Zhang and De Min Wang and Jun Ye Li and Chun Min Shang and Jia Xin Xiong and Hong Cai Xie},
  title = {{Deviation analysis of rotational inertia measurement based on torsion bar method}},
  booktitle = {Vibroengineering},
  year = {2018},
  doi = {10.21595/vp.2018.20317},
}
Figure