Abstract
本研究では,2016年熊本地震における熊本県益城町の家屋被害認定調査結果に基づいて建物被害分析を行うとともに,推定地震動分布と組み合わせて建物被害関数を構築した.建物被害分析では構造別,建築年代別,木造建物の屋根形式別・階数別に被害を分析した.その結果,木造建物の全壊率は,RC造,S造,LS造と比較して全体的に大きく,建築年代が古くなるほど大きくなる傾向が顕著にみられた.また,最大地表速度および計測震度に対する,構造別,木造の建築年代別の益城町の建物被害関数を構築した.益城町の被害関数は,1995年兵庫県南部地震の結果に基づく経験式と比べて,同一の最大地表速度における全壊率が低くなる傾向がみられた.
Introduction
In Japan, disaster management and insurance models often rely on "fragility curves" derived from the 1995 Great Hanshin-Awaji (Kobe) Earthquake. However, building codes and construction techniques have changed drastically in the decades since. The 2016 Kumamoto Earthquake, specifically in the hard-hit town of Mashiki, provided a unique opportunity to update these models. This study bridges the gap between outdated 1990s models and modern construction realities by analyzing how different building types and construction eras performed under extreme stress.
Datasets and Methodology
The researchers integrated official "Disaster-Victim Certificates" (罹災証明) for 10,159 buildings in Mashiki with high-resolution estimated ground motion data. Using the QuiQuake system, they estimated Peak Ground Velocity (PGV) and JMA Seismic Intensity across the town.
The dataset was categorized by structure type, construction year, roof type, and number of floors. Statistical modeling using log-normal distribution functions allowed for the creation of fragility curves, plotting the probability of damage against shaking intensity.
Spatial Distribution of Damage
The damage in Mashiki was concentrated along specific zones, correlating with the proximity to fault lines and local soil conditions. The spatial analysis of these certificates provides the ground truth for the fragility models.
Key Insights
The "Kobe Benchmark" is Shifting
For the same level of ground shaking (PGV), buildings in 2016 were generally less likely to collapse than those in 1995. This suggests that the overall "seismic health" of Japanese towns has improved due to the replacement of old stock and better retrofitting.
The 1981 Watershed and Modern Resilience
The "New Seismic Design Code" of 1981 remains the most significant predictor of survival. Wooden buildings built after 1981 showed a marked decrease in collapse rates, with even further improvements seen in post-2000 constructions. Conversely, older wooden homes, especially those with heavy traditional tile roofs, showed significantly higher vulnerability.
Structural Performance
While wooden structures had the highest collapse rates, standard Steel (S) and Light-gauge Steel (LS) structures showed very similar fragility curves, likely because they are governed by similar modern design philosophies.
Conclusion
The developed fragility curves provide specific regression coefficients for PGV and JMA intensity, allowing for high-confidence predictions of structural damage. These updated models are essential for modern disaster mitigation planning in Japan, reflecting the evolution of building standards since the 1990s.
Summary updated