Abstract
A quantitative method for the evaluation of facial swelling in rats with middle cerebral artery occlusion (MCAO) was established using a mathematical method for the first time. The rat model of MCAO was established via bilateral common carotid artery ligation. Three groups of rats with the same baseline were selected (model group, positive drug group, and control group) according to their behavioral score and body weight 24 h after surgery. Drug administration was initiated on post-MCAO day 8 and was continued for 28 days. Mobile phones were used to collect facial images at different time points after surgery. In facial image analysis, the outer canthi of both eyes were used as the facial dividing line, and the outer edge of the rat's face was framed using the marking method; the framed part was regarded as the facial area (S) of the rats. The histogram created with Photoshop CS5 was used to measure the face area in pixels. The distance between the outer canthi of both eyes (Le) and the vertical line from the tip of the nose to the line joining the eyes (H1), and the line from the tip of the nose to the midpoint of the line joining the eyes (H2), were recorded. The facial area was calibrated based on the relationship between H1 and H2. The distance between the eyes (Le) was used to calibrate the face area by unifying the scale across images. When compared with the control group, the facial area of the model group gradually increased from postoperative day 1 to day 7, showing a significant difference by day 7. Positive drugs exhibited the effect of improving facial swelling. This method is convenient and provides a quantitative alternative to subjective human judgment.
Introduction: The Challenge of Subjective Assessment
In ischemic stroke research, the Middle Cerebral Artery Occlusion (MCAO) rat model is the gold standard for simulating human brain injury. While researchers have long noted that these rats experience facial swelling due to inflammatory responses and changes in intracranial pressure, this swelling has historically been assessed through "gross examination"—essentially a subjective visual assessment by a researcher.
Subjective scoring is prone to human bias and lacks the sensitivity required to detect subtle improvements during drug trials. The primary challenge in quantifying this swelling is that rats are moving targets; a 2D photo of a 3D swelling is easily distorted by the animal’s distance from the lens and the angle of its head.
Methodology: Quantitative Facial Image Processing
The study utilized a cohort of 30 male Sprague-Dawley rats, divided into a Model Group (MCAO surgery), a Positive Drug Group (MCAO + Donepezil hydrochloride), and a Control Group. The workflow moved from surgery to digital image processing:
- Image Acquisition: Standard smartphones were used to capture facial images of unanesthetized rats at multiple time points (Days 1–28 post-surgery).
- Facial Segmentation: Using Photoshop CS5, researchers defined the facial area ($S$) by marking the outer canthi of the eyes as a dividing line and framing the outer edges of the face.
- Pixel Measurement: The Photoshop "Histogram" tool was used to count the total number of pixels within the framed facial area.
Geometric Calibration
To ensure measurements were comparable across different photos, the researchers introduced a mathematical calibration method using three variables:
- $Le$ (Interocular Distance): Since the distance between a rat's eyes is fixed by its bone structure, any change in $Le$ in a photo indicates a change in the camera's distance. Unifying $Le$ across images normalized the scale.
- $H1$ and $H2$: These variables represent the vertical distance from the nose tip to the eye line. By comparing these, the researchers could mathematically correct for the rat tilting its head up (hyperextension), down (head drop), or turning it side-to-side.
Results and Key Insights
The study confirmed that facial swelling in MCAO rats peaks around postoperative day 7. In the model group, the facial area increased significantly from day 1 to day 7, reaching a statistically significant difference ($p < 0.05$) compared to the control group.
Crucially, the method successfully detected the ameliorative effect of Donepezil; rats treated with the drug showed significantly less facial swelling than the untreated model group. The researchers found that while head rotation ($H1/H2$) had a minor effect on the overall conclusion, calibrating for camera distance ($Le$) was extremely critical to reduce data variance and reveal the true biological trend.
Discussion and Future Directions
This method provides a low-cost, objective tool for evaluating anti-inflammatory drug efficacy in stroke models. By using the interocular distance as an invariant reference, researchers can achieve accurate scaling without physical rulers.
The primary limitation remains the manual nature of the current segmentation process in Photoshop. Future work should focus on integrating artificial intelligence for automated landmark detection. Automating the identification of eyes and nose tips could transform this into a high-throughput, real-time tool for laboratory research.
Summary updated