Development of a Meander-Coil-Type Dual Magnetic Group Circumferential Magnetostrictive Guided Wave Transducer for Detecting Small Defects Hidden behind Support Structures

Jinjie Zhou, Hang Zhang, Yuepeng Chen, Jitang ZhangMicromachines 2024 · DOI

TL;DR

This paper introduces a novel meander-coil-type dual magnetic group circumferential magnetostrictive guided wave transducer designed to detect small defects hidden behind pipeline supports in challenging environments like offshore oil platforms. The developed transducer significantly enhances energy conversion efficiency and detection sensitivity, enabling the effective detection of defects as small as a 2mm round hole, outperforming traditional EMATs.

What Problem Does This Paper Address?

Offshore oil platforms are complex networks of pipelines operating under high temperatures and pressures, making them susceptible to defects like rust, perforation, and cracks. Detecting small defects, especially those hidden behind pipeline support structures, is a critical but difficult task. The presence of these supports can scatter guided wave energy, hindering detection. Furthermore, the confined spaces on these platforms limit access and the size of inspection equipment. Existing ultrasonic guided wave techniques, particularly traditional EMATs, often suffer from weak signal generation and low signal-to-noise ratios, making it hard to reliably detect small, hidden defects. This paper aims to address this gap by developing a specialized transducer capable of circumferential detection in narrow spaces with improved sensitivity and efficiency.

Methods

The core of this research is the development and optimization of a Meander-Coil-Type Dual Magnetic Group Circumferential Magnetostrictive Guided Wave Transducer (MPT). This transducer utilizes a magnetostrictive patch, a meander coil, and two sets of permanent magnets to generate high-frequency circumferential shear horizontal (CSH) guided waves.

Key methodological aspects include:

  • Magnetostrictive Principle: The transducer leverages the magnetostrictive effect, where a material changes shape in response to a magnetic field. This is used for both excitation (converting electrical signals to mechanical waves) and reception (converting mechanical waves back to electrical signals via the inverse magnetostrictive effect).
  • Circumferential CSH Wave Generation: The design specifically aims to excite the CSH2 mode guided wave, which is less affected by surrounding fluids and has lower attenuation, making it suitable for pipeline inspection. The orientation of the static magnetic field from the permanent magnets and the dynamic magnetic field from the coil is crucial for generating this specific wave mode.
  • Meander Coil Design: A double-layer PCB meander coil is employed to enhance the dynamic magnetic field amplitude. The coil's spacing is designed to be half the wavelength of the target guided wave.
  • Dual Magnetic Group: Two sets of permanent magnets are symmetrically placed to provide a biased magnetic field. This biased field is crucial for operating the magnetostrictive material in its linear working region, minimizing frequency doubling and improving sensitivity.
  • Optimization through Simulation and Experiment: The paper extensively uses magnetic field simulations (e.g., COMSOL) to study the influence of various parameters on the biased magnetic field and energy conversion efficiency. These simulations guide experimental optimization of:
  • Number of Magnet Rows: Investigating the impact of magnet arrangement on field uniformity.
  • Magnet Size (Length) and Lifting Distance: Optimizing the static magnetic field strength and uniformity by adjusting the permanent magnet geometry and its placement relative to the magnetostrictive patch.
  • Material Selection: A comparative study was conducted between Fe-Co-V alloy and Nickel for the magnetostrictive patch, with Fe-Co-V showing superior performance.
  • Experimental Setup: A dedicated experimental system was built, comprising an excitation and reception transducer, function generator, power amplifier, and signal collector, to test the transducer's performance on a pipeline with simulated defects.

Datasets

Not discussed in the paper. The experiments were conducted on a custom-built pipeline with artificially introduced defects (cracks and circular holes) of varying sizes.

Key Insights and Ideas

  • Optimizing the Biased Magnetic Field is Key: The research strongly emphasizes that the performance of magnetostrictive transducers is highly dependent on the biased magnetic field provided by permanent magnets. Properly tuning this field (through magnet arrangement, size, and lift distance) is crucial for operating in the linear region, maximizing energy conversion, and achieving high signal-to-noise ratios.
  • Dual Magnetic Group Enhances Circumferential Detection: The specific arrangement of two magnetic groups, combined with the meander coil, is shown to be effective for generating and receiving circumferential guided waves, a critical requirement for inspecting pipelines behind supports.
  • Magnetostrictive Transducers Offer Superior Performance: The study demonstrates that magnetostrictive patch transducers (MPTs) significantly outperform traditional Lorentz-force-based EMATs in terms of excitation energy and detection sensitivity, especially for small, hidden defects.
  • CSH2 Mode is Well-Suited for This Application: The choice of the CSH2 mode is justified by its robustness against environmental factors and its suitability for detecting defects in pipeline structures.
  • Defect Size and Type Influence Echo Amplitude: The research confirms that larger defects generally produce stronger echo signals, but even small defects (like a 2mm hole) can be detected with the optimized MPT, highlighting its sensitivity.

Key Results

  • Enhanced Defect Detection: The developed MPT can effectively detect small defects, including a 2 mm round hole hidden behind a support structure.
  • Improved Signal Amplitude: The amplitude of the defect signal was enhanced by 1.9 times compared to the minimum amplitude achieved during optimization.
  • High-Frequency Operation: The transducer effectively excites and receives CSH2 mode guided waves with a center frequency of 1.6 MHz.
  • Superior to Traditional EMATs: The MPT's detection signal amplitude was approximately twice that of a traditional PPM EMAT, with significantly better signal-to-noise ratio and detection accuracy, particularly for small defects like the 2mm round hole.
  • Optimized Magnet Configuration: Experimental results indicated that using two rows of magnets provided a good balance of signal strength and uniformity, avoiding the clutter seen with three rows. A permanent magnet size of 7 mm with an optimized lifting distance also yielded strong and stable signals.
  • Material Advantage: The Fe-Co-V magnetostrictive strip demonstrated a defect wave signal amplitude approximately twice that of a Nickel strip.

Limitations and Future Work

  • Limited to Circumferential Detection: The current design is optimized for circumferential detection. While effective for the stated problem, it may not be directly applicable to axial defect detection without modification.
  • Experimental Pipeline Setup: The experiments were conducted on a controlled pipeline setup with artificial defects. Real-world offshore environments may present additional complexities (e.g., varying surface conditions, complex support geometries, environmental noise) that could affect performance.
  • Quantitative Defect Sizing: While the transducer can detect and locate defects, the paper focuses on detection and qualitative analysis. Further work might be needed for precise quantitative sizing of defects.

Future work could involve:

  • Extending to Axial Detection: Developing a transducer capable of both circumferential and axial guided wave inspection.
  • Array Design: Creating transducer arrays for faster scanning and potentially for imaging applications.
  • Real-World Deployment: Testing the transducer in actual offshore pipeline environments to assess its robustness and performance under more challenging conditions.
  • Advanced Signal Processing: Exploring more sophisticated signal processing techniques to further enhance defect characterization and reduce noise.

Summary updated

Abstract

In order to solve the problem that small defects hidden behind pipeline support parts are difficult to detect effectively in small spaces, such as offshore oil platforms, a meander-coil-type dual magnetic group circumferential magnetostrictive guided wave transducer is developed in this paper. The transducer, which consists of a coil, two sets of permanent magnets, and a magnetostrictive patch, can excite a high-frequency circumferential shear horizontal (CSH) guided wave. The energy conversion efficiency of the MPT is optimized through magnetic field simulation and experiment, and the amplitude of the defect signal is enhanced 1.9 times. The experimental results show that the MPT developed in this paper can effectively excite and receive CSH<sub>2</sub> mode guided waves with a center frequency of 1.6 MHz. Compared with the traditional PPM EMAT transducer, the excitation energy of the transducer is significantly enhanced, and the defects of the 2 mm round hole at the back of the support can be effectively detected.