Development of a gamma-ray imaging detector based on ceramic scintillators with SiPM readout
Abstract
Abstract Depth of interaction (DOI) measurements can provide additional position information when long scintillator bars or scintillator pixels with relatively large thickness are employed in gamma-ray imaging detectors. In this study, commercially available GGAG ceramic scintillators were used to fabricate a gamma-ray imaging detector. The light attenuation, DOI resolution, and spectroscopic performance of 3.0× 3.0× 48.0 mm 3 ceramic bars were evaluated using double-side SiPM readout. The measured full width at half maximum (FWHM) energy resolution values ranged between 7.6% and 8.7% at 511 keV. The DOI resolution was approximately 4 mm (FWHM). A prototype two-layer Compton imaging detector was fabricated based on 32 ceramic bars and the signals were readout using four 16-ch application-specific integrated circuits. The lutetium background was evaluated and a 22 Na point source (0.19 μSv/h 511 keV gamma-ray dose rate at 50 cm) was used to verify the feasibility of using the commercial GGAG ceramic material in nuclear security applications. The source can be located within 120 s using a simple back projection method. The angular resolution measure was estimated as 15 ∘ (FWHM). A filtered back projection based algorithm improved the angular resolution (FWHM) to 9.2 ∘ .
BibTeX
@article{xu2021development,
author = {L. Xu and Yang Tian and Y. Li},
title = {{Development of a gamma-ray imaging detector based on ceramic scintillators with SiPM readout}},
journal = {Journal of Instrumentation},
year = {2021},
doi = {10.1088/1748-0221/16/10/p10005},