NeurIPS 2026Coming to NeurIPS in Sydney?Explore papers, orals & directions

Developing an Online Measurement Device Based on Resistance Sensor for Measurement of Single Grain Moisture Content in Drying Process

Chengjie Li, Bin Li, Junying Huang, Changyou Li2020

TL;DR

This paper presents a novel online device that measures the moisture content of individual grains in real-time using a resistance-based sensor. By analyzing the unique "inverted parabola" waveform generated as a grain is crushed, the device achieves high accuracy (±0.5% error) across a wide range of moisture levels and temperatures, offering a significant advancement for intelligent grain drying systems.

What Problem Does This Paper Address?

Accurate and real-time monitoring of grain moisture content is crucial for optimizing drying processes, ensuring quality, and reducing energy consumption. Traditional methods like the oven method are time-consuming and destructive, making them unsuitable for online applications. Existing indirect methods often struggle with the inherent non-uniformity of moisture distribution within a batch of grains and can be affected by environmental factors. Specifically, measuring the moisture content of single grains dynamically and reliably has been a persistent challenge, hindering the development of truly intelligent and adaptive grain drying equipment that can respond to individual grain conditions.

Methods

The core of this work lies in developing an experimental apparatus and an analytical method to measure single grain moisture content.

  • Resistance Sensor Design: A key component is a resistance sensor unit consisting of two mutually insulated stainless-steel rollers with straight-line knurling. A single grain is fed between these rollers, which rotate at a controlled speed (20 R/min). As the grain is crushed, its electrical resistance is measured in real-time.
  • Data Acquisition Circuit: A high-precision analog-to-digital converter (AD7793) is used in a comparative method. The grain's equivalent resistance is measured in series with a known proportion resistance. This allows for accurate resistance measurement across a very wide range, overcoming limitations of traditional methods.
  • Waveform Analysis: The real-time resistance measurements generate a characteristic "inverted parabola" waveform. The paper identifies the "peak value" and "peak area" of this waveform as key indicators of moisture content.
  • Analytical Calculation Method: To enable direct comparison of waveforms across different testing times, the authors normalize the time series of the electrical properties. They then investigate the correlation between the peak value/area and moisture content, developing regression equations for different grain types.
  • Device Development: An online measurement device was built integrating the resistance sensor, data acquisition unit, and custom software running on a Cortex-M3 microcomputer. This device includes signal shielding and a user-friendly interface.

Datasets

The study utilized four types of grains:

  • Round rough rice (Xiangzaoxian 45#)
  • Wheat (Lumai 21#)
  • Barley (Longpimai 2#)
  • Long rough rice (Nanjing 9108#)

These grains were sourced from local farms and prepared to achieve various moisture content levels (10–35% w.b.) through controlled soaking and drying. The experiments were conducted under controlled laboratory conditions and in a real-world field test scenario.

Key Insights and Ideas

  • The "Inverted Parabola" Signature: The consistent "inverted parabola" waveform generated by crushing individual grains is a robust indicator of their electrical properties and, consequently, their moisture content. This waveform provides a rich source of information beyond a single resistance reading.
  • Peak Value vs. Peak Area: Both the peak value and peak area of the resistance waveform correlate with moisture content. However, the authors found that peak value is more suitable for high moisture content, while peak area is better for low moisture content, suggesting a complementary approach for comprehensive measurement.
  • Gap Width is Crucial: The gap width between the rollers in the resistance sensor has a more significant impact on sensor performance than the roller diameter. Optimizing this gap is critical for stable and accurate measurements, balancing the need for sufficient resistance detection with the force required for extrusion.
  • Temperature Robustness: The developed device demonstrates excellent performance across a wide temperature range (–20 to 50 °C), a critical factor for real-world drying applications where temperatures can fluctuate significantly.

Key Results

  • High Accuracy: The developed online measurement device achieved an absolute measurement error within ±0.5% in both lab and field tests.
  • Wide Applicability: The device demonstrated reliable performance across four different grain species and a moisture content range of 10–35% w.b.
  • Temperature Tolerance: The device maintained accuracy across a temperature range of –20 to 50 °C.
  • Strong Correlations: Regression equations for calculating moisture content based on peak value and peak area showed high coefficients of determination (R²) ranging from 0.981 to 0.998 for the tested grains.
  • Improved Uniformity Measurement: The device's ability to measure individual grain moisture content contributes to better characterization of drying uniformity, with field tests showing a gradual increase in uniformity from 92.8% to 98.7% during the drying process.

Limitations and Future Work

  • Moisture Content Range: While the device performs well within the 10–35% w.b. range, its performance at extremely low or high moisture content levels outside this range is not explicitly detailed.
  • Grain Variety Specificity: The study developed specific regression equations for four grain types. Further work may be needed to generalize these equations or develop methods for adapting to new grain varieties.
  • Control Mechanism Integration: The authors suggest that future research should focus on investigating the control mechanism of drying quality based on the data provided by this developed device, moving towards fully automated intelligent drying systems.

Summary updated

BibTeX
@misc{li2020developing,
  author = {Chengjie Li and Bin Li and Junying Huang and Changyou Li},
  title = {{Developing an Online Measurement Device Based on Resistance Sensor for Measurement of Single Grain Moisture Content in Drying Process}},
  year = {2020},
  doi = {10.3390/s20154102},
}

Loading related content...

Figure