Determination of trace aniline and benzidine in underground water using online SPE eoupled with liquid chromatography-tandem mass spectrometry
Lists
Only you see this
Abstract
An analytical method based on on-line solid phase extraction(SPE) coupled with liquid chromatography-tandem mass spectrometry for determination of aniline and benzidine in underground water was developed.Sample was SPE concentrated by a HLB cartridge and separated on a HSS T3 column with a gradient mobile phase of acetonitrile and aqueous 0.1% formic acid,then analyzed by the tandem mass spectrometry.Quantification was performed by external standard calibration.When the sample injection volume was 5mL,the linear ranges of aniline and benzidine were 50.0 ~ 20.0 μg/L and 5.0 ~ 2.0 μg/L,respectively,with both correlation coefficients of 0.999.The detection limits of aniline and benzidine in this the methods were10.0 ng/L and 0.20 ng/L,respectively.The satisfying recoveries of the spiked water samples ranged from 65%to 86% for aniline,and ranged from 85% to 98% for benzidine.This method proposed in this paper is simple,rapid,highly sensitive and good reproducible and could be used to detect trace aniline and benzidine in underground water.