Determination of Total Mercury in Soil by Direct Mercury Analyzer

Yan LuoChinese 2012

Abstract

The method for rapid determination of total mercury in soil was established by direct mercury analyzer.The conditions such as drying temperature,drying time,decomposition temperature and decomposition time were optimized by experiment.The linear relationship,precision experiment was carried out.The linearity range of the method was 0—500ng,and the correlation coefficient was greater than or equal to 0.9995,the detection limit was 0.0032ng,and the relative standard deviations was 0.56%.The method is simple,rapid,sensitive and accurate,and that is suit to determination of total mercury in soil.