TL;DR
This paper presents a novel and rapid method for detecting seven harmful Alternaria toxins (ATs) in infant milk powder using solid-phase extraction coupled with ultra-performance liquid chromatography-tandem mass spectrometry (SPE-UPLC-MS/MS). The developed method is accurate, sensitive, and suitable for routine food safety monitoring, with a key finding that only one sample out of sixty tested contained tentoxin.
What Problem Does This Paper Address?
Alternaria toxins (ATs) are toxic metabolites produced by the fungus Alternaria, which is commonly found in soil, grains, vegetables, and fruits. These mycotoxins pose significant health risks to humans and animals, including acute and chronic toxicity, and potential carcinogenic, teratogenic, and mutagenic effects. Infant milk powder, particularly formulations containing vegetable oil, is susceptible to contamination by Alternaria alternata. Given the vulnerability of infants and the importance of milk powder as a primary food source, the rapid and accurate detection of ATs in these products is crucial for ensuring food safety. Existing regulatory standards in China only cover a limited number of ATs and are not comprehensive for infant milk powder, highlighting a need for robust analytical methods.
Methods
The researchers developed a method combining solid-phase extraction (SPE) for sample cleanup and enrichment with ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for sensitive detection and quantification.
Key methodological steps and optimizations include:
- Chromatographic Conditions: A BEH-C18 column was chosen for its good separation capabilities. A mobile phase consisting of 0.1% formic acid in water and acetonitrile was used with a gradient elution program.
- Extraction Conditions: A multi-step extraction process was optimized using a combination of acetonitrile-water and acetonitrile-methanol-water mixtures. Horizontal shaking for 30 minutes was found to be the most effective extraction method.
- Solid-Phase Extraction (SPE): An HLB (Hydrophilic-Lipophilic Balance) cartridge was selected for SPE purification. The activation, washing, and elution steps were carefully optimized. Notably, the eluted sample was directly analyzed without concentration, contributing to the method's speed.
- Mass Spectrometry (MS): Electrospray ionization (ESI) was employed, with alternating positive and negative ion modes to detect all seven target ATs. Multiple Reaction Monitoring (MRM) was used for highly selective and sensitive detection.
- Method Validation: The method was validated for linearity, limit of detection (LOD), limit of quantification (LOQ), recovery, and precision. Matrix effects were also investigated and compensated for using a matrix-matched calibration approach.
Datasets
The study utilized:
- AT Standards: Pure standards of the seven target Alternaria toxins (alternariol monomethyl ether, altenuene, tenuazonic acid, alternariol, tentoxin, altenusin, and altertoxin I) were used for method development and validation.
- Infant Milk Powder Samples: Sixty samples of infant milk powder were collected from the domestic market, categorized into three stages (Stage 1: 0-6 months, Stage 2: 6-12 months, Stage 3: 12-36 months), with 20 samples from each stage. These samples were used for method application and real-world testing.
Key Insights and Ideas
- Optimized Extraction is Crucial: The study highlights that the choice of extraction solvent ratio and method significantly impacts AT recovery. A specific combination of acetonitrile-water and acetonitrile-methanol-water, coupled with horizontal shaking, proved most effective for infant milk powder.
- SPE Simplifies Analysis: Using an HLB SPE cartridge effectively cleaned up the complex milk powder matrix, removing interfering substances and concentrating the target toxins without the need for a separate concentration step, thus streamlining the workflow.
- Dual Ionization Mode is Necessary: Detecting all seven ATs required switching between positive and negative electrospray ionization modes, as some toxins ionize better in positive mode and others in negative mode.
- Low Contamination in Infant Formula: A significant finding is the very low prevalence of ATs in the tested infant milk powder samples, with only one sample showing detectable levels of tentoxin. This suggests that current manufacturing and quality control processes for infant formula are generally effective in preventing AT contamination.
Key Results
- Method Performance: The developed SPE-UPLC-MS/MS method demonstrated excellent linearity (R² > 0.9903) for all seven ATs in the concentration range of 0.5-200 µg/L.
- Sensitivity: Limits of detection (LOD) ranged from 0.15 to 0.64 µg/kg, and limits of quantification (LOQ) ranged from 0.54 to 2.24 µg/kg, indicating high sensitivity.
- Accuracy and Precision: Average recoveries for the seven ATs were between 79.1% and 114.3%, with relative standard deviations (RSD) below 8.87%, demonstrating good accuracy and precision.
- Real Sample Analysis: Out of 60 infant milk powder samples tested, no ATs were detected in Stage 1 or Stage 2 samples. In Stage 3 samples, only one sample contained tentoxin at a concentration of 4.97 µg/kg.
Limitations and Future Work
- Matrix Effects: The study acknowledged significant matrix effects, with some ATs experiencing ionization enhancement (e.g., AME, ALT, ALS, ATX-I) and others suppression (e.g., Ten, AOH). While matrix-matched calibration was used to mitigate this, it's a common challenge in complex matrices.
- Limited ATs: The method targets seven specific ATs. Future work could expand the scope to include a broader range of ATs or other mycotoxins.
- Regulatory Standards: The paper notes the lack of comprehensive regulatory standards for ATs in infant milk powder, suggesting that this method could provide valuable data for establishing such standards.
- Further Validation: While the method was applied to 60 samples, further validation across a wider range of infant milk powder brands and formulations could enhance its robustness.
Summary updated