Determination of Phenols in Soak Water from Drinking Water Related Products by Gas Chromatography-Mass Spectrometry with Large Volume Injection
Lists
Only you see this
Abstract
A method was developed for the determination of phenols in soak water from drinking water related products by gas chromatography-mass spectrometry(GC-MS) with on-column large volume injection(OCI-LVI) and coupled column separation.The sample was firstly soaked according to related standard method.And then,0.2 g/L of Na2S2O3 was used as reductant to remove excessive chlorine.After spiked 2,4-dibromo-phenol as internal standard,10 mL of the soak water was adjusted to pH 6.8,saturated by NaCl and extracted by 1 mL of organic solvent.Approximately 30 μL of up-layer extract was used as injecting sample.The advantage of the short coupled polar column in increasing retention capacity of volatile phenols in OCI-GC-MS system was discussed.The LODs were 0.1-1 μg/L.The recoveries were 76.7%-112% with 5.94%-12.4% of RSD.
BibTeX
@inproceedings{xiao2011determination,
author = {Xu Xiao},
title = {{Determination of Phenols in Soak Water from Drinking Water Related Products by Gas Chromatography-Mass Spectrometry with Large Volume Injection}},
booktitle = {CHINESE},
year = {2011},
}Loading related content...