Determination of 18 caine anesthetics in animal meat using solid phase extraction combined with ultra-performance liquid chromatography-tandem mass spectrometry

Wu ShaoMing, Li-Qun Ouyang, Meng Peng, Meng-Hang He, Lin Qin, Yankai Chen, Wenjing Liu, Xiaoming Su, Ming DaiChinese 2023 · DOI

TL;DR

This paper presents a novel, rapid, and sensitive analytical method for simultaneously detecting 18 caine anesthetics in animal meat. By combining solid-phase extraction (SPE) with ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), the researchers developed a robust technique that overcomes the challenges of complex meat matrices and achieves excellent recovery and precision.

What Problem Does This Paper Address?

Caine anesthetics are increasingly used in animal husbandry and transportation to sedate animals, which can lead to their residues being present in meat products. The presence of these residues is a concern for food safety due to potential health risks, including neurotoxicity and cardiovascular effects. However, detecting these compounds in animal meat is challenging due to the complex matrix, which contains interfering substances like proteins, fats, and phospholipids, and the very low concentrations of the residues. Existing analytical methods often lack the sensitivity, speed, or comprehensive scope needed for effective monitoring. This paper aims to fill this gap by developing a method capable of simultaneously detecting a broad range of caine anesthetics with high sensitivity and accuracy in animal meat.

Methods

The core of this study is the development of a combined sample preparation and analytical technique. The sample preparation involves a three-step process:

  1. Ultrasound-assisted extraction: Meat samples are extracted using a mixture of water and 0.1% formic acid in acetonitrile.
  2. Solid-phase extraction (SPE): An Oasis PRIME HLB column is used for purification. This column is chosen for its ability to retain impurities while allowing the target compounds to pass through, simplifying the process.
  3. DMSO-assisted concentration: The extracted and purified solution is concentrated using dimethyl sulfoxide (DMSO) and nitrogen gas, followed by reconstitution in an acetonitrile-water mixture.

The purified extract is then analyzed using Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry (UPLC-MS/MS). Key aspects of the UPLC-MS/MS method include:

  • Chromatographic Separation: An HSS T3 column is employed for optimal separation of the 18 caine anesthetics. The mobile phase consists of a gradient of 0.1% formic acid in water (with ammonium acetate) and methanol.
  • Mass Spectrometry Detection: An electrospray ionization (ESI) source is used in positive ion mode, with multiple reaction monitoring (MRM) for sensitive and selective detection. MS parameters, including collision energies, were optimized for each of the 18 compounds.

Datasets

The study utilized commercially available standard solutions of 18 caine compounds. For method validation, blank samples of pork, beef, and mutton were used. These blank matrices were spiked with known concentrations of the target analytes to assess recovery, precision, and matrix effects. No new datasets were introduced; rather, the method was validated on common animal meat matrices.

Key Insights and Ideas

  • PRIME HLB SPE for Efficiency: The choice of the Oasis PRIME HLB SPE column proved crucial. Unlike traditional SPE methods that require activation, washing, and elution steps, this column allows for a "pass-through" purification of impurities, significantly simplifying the sample preparation.
  • DMSO as a Crucial Re-dissolving Agent: The addition of DMSO during the concentration step was vital. Without it, certain target compounds (like procaine, lidocaine, prilocaine, and cocaine) experienced significant losses during the drying process. DMSO effectively prevented these losses, ensuring higher recoveries.
  • Optimized Mobile Phase for Separation: The combination of 0.1% formic acid in water (with ammonium acetate) and methanol as the mobile phase, along with the HSS T3 column, was critical for achieving baseline separation of all 18 caine anesthetics, including challenging isomer pairs.
  • Low Matrix Effects: The method demonstrated low matrix effects (ME) across pork, beef, and mutton samples, indicating that the complex biological matrix did not significantly interfere with the MS detection. This is essential for accurate quantification.

Key Results

  • Linearity and Sensitivity: The method exhibited excellent linearity for all 18 caine anesthetics in the range of 1.00-50.0 µg/L, with correlation coefficients (R²) greater than 0.999.
  • Detection and Quantification Limits: The limits of detection (LODs) were as low as 0.2-0.5 µg/kg, and the limits of quantification (LOQs) were 0.6-1.5 µg/kg, demonstrating high sensitivity.
  • Recovery and Precision: In pork, beef, and mutton samples, the average recoveries for the 18 compounds ranged from 83.4% to 100.4%, with relative standard deviations (RSDs) between 3.1% and 8.5%. This indicates good accuracy and precision.
  • Real Sample Analysis: When applied to 10 samples each of randomly purchased pork, beef, and mutton from local markets, none of the 18 target caine anesthetics were detected. This suggests that, at the time of sampling, residues were below the method's detection limits.

Limitations and Future Work

  • Limitations: While the method is robust, the study did not detect any residues in the tested real samples. This could imply that the use of these anesthetics is well-controlled in the studied region, or that the residues are below the method's detection limits. The paper does not explicitly discuss limitations related to the stability of the extracted samples over extended periods beyond the 1-week stability test.
  • Future Work: The authors suggest that this simple, rapid, and sensitive method can provide technical support for food safety departments in China to monitor caine anesthetic residues in animal meat. Future work could involve applying this method to a wider range of animal products and geographical locations, and potentially expanding the panel of detected anesthetics. Further investigation into the long-term stability of extracted samples and the development of even faster sample preparation techniques could also be beneficial.

Summary updated

Abstract

Because of the widespread application of anesthetic drugs in the fields of animal breeding and transportation, demand for the rapid, sensitive detection of anesthetic drugs in animal meat is increasing. The complex animal meat matrix contains various interfering substances, such as proteins, fats, and phospholipids, along with anesthetic drug residues at very low concentrations. Therefore, adopting appropriate pretreatment methods is necessary to improve the sensitivity of detection. In this study, a rapid, accurate analytical method based on ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) and solid phase extraction (SPE) was established to determine the contents of 18 caines in animal meat. The MS parameters, such as the collision energies of 18 caines, were optimized. Furthermore, the chromatographic separation conditions and response intensities of the caine in different mobile phases were compared. The effects of different pretreatment conditions on the extraction efficiencies of the 18 caines in meat samples and those of different purification conditions, such as extraction solvent, SPE column, and dimethylsulfoxide (DMSO) dosage, on their recoveries were investigated. Combined with the external standard method, the 18 caines in meat were successfully quantified. Sample pretreatment is a three-step process. First, in ultrasound-assisted extraction, 2.0 g samples were added to 2.0 mL water and extracted using 10 mL 0.1% (v/v) formic acid in acetonitrile under ultrasound conditions for 10 min. SPE was then performed using an Oasis PRIME HLB column. Finally, DMSO-assisted concentration was employed: the organic layer was collected and dried at 40 ℃ under a stream of N<sub>2</sub> gas with the addition of 100 μL DMSO. Acetonitrile-water (1∶9, v/v) was added to the residue to yield a final volume of 1.0 mL for use in UPLC-MS/MS. The 18 caines were separated using an HSS T<sub>3</sub> (100 mm×2.1 mm, 1.8 μm) column with 0.1% (v/v) formic acid in water (containing 0.02 mmol/L ammonium acetate) and methanol as mobile phases. Samples were detected using an electrospray ion source (ESI) in the positive ion and multiple reaction monitoring (MRM) modes during UPLC-MS/MS. Under the optimized conditions, the 18 target caine anesthetics displayed good linearities in the range of 1.00-50.0 μg/L, and the correlation coefficients (<i>R</i><sup>2</sup>) were >0.999. The respective limits of detection (LODs) and quantification (LOQs) were 0.2-0.5 μg/kg, and 0.6-1.5 μg/kg. In pork, beef, and mutton samples, the recoveries obtained at three spiked levels were 83.4%-100.4% with relative standard deviations (RSDs) of 3.1%-8.5%. This simple, rapid, sensitive method may be applied in the detection of 18 caine anesthetics in animal meat and may provide technical support to the food safety department in China in monitoring the residues of caine anesthetics in animal meat.
BibTeX
@inproceedings{shaoming2023determination,
  author = {Wu ShaoMing and Li-Qun Ouyang and Meng Peng and Meng-Hang He and Lin Qin and Yankai Chen and Wenjing Liu and Xiaoming Su and Ming Dai},
  title = {{Determination of 18 caine anesthetics in animal meat using solid phase extraction combined with ultra-performance liquid chromatography-tandem mass spectrometry}},
  booktitle = {Chinese},
  year = {2023},
  doi = {10.3724/sp.j.1123.2022.08019},
}
Figure