Design of Airborne Hyperspectral Automatic Filling Device for Liquid Nitrogen Refrigeration
Abstract
Abstract To maintain sensitivity of the sensor, especially the infrared band sensor, liquid nitrogen is needed for cooling during the imaging process of airborne hyperspectrometer. However, traditional filling process requires a lot of manual intervention, which is not only time-consuming and labor-intensive, but also creates great potential safe hazard during aviation operations. In view of this, this paper designs an airborne hyperspectral automatic filling device for liquid nitrogen using time-delay electromagnetic switch, pressure sensing detector and electromechanical device, which achieves the purpose of automatic liquid nitrogen filling, increases operation efficiency of airborne hyperspectral equipment, reduces air stage operation steps, and guarantees personal safety of air operators, thus playing a good demonstration role in further standardizing and optimizing the technical process of air-borne hyperspectral remote sensing data.
BibTeX
@article{han2022design,
author = {Yachao Han and Jing Li and Zihong Gao and Jie Chen and Zhiyang Nie},
title = {{Design of Airborne Hyperspectral Automatic Filling Device for Liquid Nitrogen Refrigeration}},
journal = {Journal of Physics Conference Series},
year = {2022},
doi = {10.1088/1742-6596/2235/1/012044},
}Ask Althea to put this paper to the test.