Design of a Seawater Desalination System with Two-Stage Humidification and Dehumidification Desalination Driven by Wind and Solar Energy

Kaijie Huang, Chengjun Qiu, Wenbin Xie, Wei Qu, Yuan Zhuang, Kaixuan Chen, Jiaqi Yan, Gao Huang, Chao Zhang, Jianfeng HaoWater 2024 · DOI

TL;DR

This paper presents a novel two-stage humidification and dehumidification (HDH) seawater desalination system powered by a hybrid wind-solar energy system. It introduces advanced MPPT algorithms for both wind and solar power to maximize energy capture and a multi-mode control strategy to ensure stable operation, achieving a daily water yield of 751.32 kg with a desalination cost of 1.4892 USD/t.

What Problem Does This Paper Address?

Remote island regions often face a dual challenge: limited access to electricity and a scarcity of freshwater. Traditional methods of obtaining freshwater, such as transportation or rainwater collection, are often insufficient and costly. While renewable energy sources like wind and solar are abundant in these regions, their intermittent nature poses a significant hurdle for powering energy-intensive processes like desalination. This paper tackles the problem of providing a reliable and cost-effective freshwater supply to these off-grid locations by integrating a two-stage HDH desalination system with a robust wind-solar hybrid power generation system.

Methods

The core of the paper lies in its integrated approach:

  • Two-Stage HDH Desalination: A novel two-stage HDH system with regenerative heat is designed to improve condensation efficiency and heat utilization, minimizing heat loss. Hot seawater is sprayed in the humidification chamber, and the resulting humid air is then cooled in the dehumidification chamber to produce freshwater.
  • Wind-Solar Hybrid Power System: A complementary wind and solar power generation system is established, coupled with a battery storage system to ensure continuous power supply.
  • Advanced MPPT Algorithms:
    • Wind Power: A "power duty cycle-based gradient perturbation method" with a variable step size is proposed for wind turbine MPPT. This method dynamically adjusts the step size to quickly approach the maximum power point (MPP) and then refines the tracking for better accuracy, outperforming traditional methods.
  • Solar Power: A Fuzzy Logic Control (FLC) algorithm is employed for photovoltaic (PV) MPPT. FLC is chosen for its robustness and ability to handle nonlinearities, offering faster tracking and reduced fluctuations compared to conventional methods like perturbation observation.
  • Multi-Mode Energy Management: Eight distinct operating modes are designed and implemented using a Programmable Logic Controller (PLC). These modes intelligently switch between wind power, solar power, battery storage, and combinations thereof, based on available energy and load demand, ensuring stable desalination operation under varying environmental conditions.

Datasets

The study utilizes experimental data collected at an experimental site in Qinzhou, Guangxi Zhuang Autonomous Region, China. This includes:

  • Environmental Data: Wind speed and solar irradiance data collected over the year 2022.
  • Operational Data: Real-time measurements of system parameters (e.g., wind speed, solar irradiance, seawater temperature, power generation, battery SOC, water yield) during experimental testing in July 2022.

No new benchmark datasets were introduced; rather, existing environmental conditions and system performance were evaluated.

Key Insights and Ideas

  • Regenerative HDH for Efficiency: The two-stage HDH design with multiple reheat stages significantly improves heat recovery, leading to higher water production efficiency compared to single-stage systems.
  • MPPT Synergy: Combining a variable step-size gradient perturbation method for wind and FLC for solar MPPT effectively addresses the limitations of traditional algorithms, leading to more efficient energy harvesting from both sources.
  • Intelligent Mode Switching is Crucial: The eight-mode operation strategy is key to ensuring the continuous and stable functioning of the desalination system, even with the inherent intermittency of renewable energy sources. This intelligent management prevents system downtime and maximizes freshwater output.
  • Cost-Effectiveness for Remote Areas: While initial investment is a factor, the system demonstrates a viable path towards affordable freshwater production for off-grid island communities, with a calculated cost of 1.4892 USD/t.

Key Results

  • Water Production: The system achieved a maximum water output of 80.63 Kg/h and a daily water yield of 751.32 Kg.
  • Desalination Cost: The estimated cost of desalination equipment is 1.4892 USD/t.
  • MPPT Performance: The proposed FLC for PV MPPT showed faster tracking and smaller amplitudes compared to P&O and Inc methods. The variable step-size gradient perturbation method for wind MPPT also demonstrated swift tracking and reduced variation.
  • System Stability: Experimental results confirmed stable system performance under typical weather conditions, meeting the anticipated standards.

Limitations and Future Work

  • Initial Investment: The paper acknowledges the significant initial investment cost for the wind-solar complementary power generation system and desalination equipment.
  • Nighttime Operation: The current system's reliance on solar collectors limits nighttime operation, as stored battery power is insufficient to drive the seawater heating devices.
  • Corrosion: Seawater can corrode pipelines, necessitating timely replacement.

Future Work Suggestions:

  • Seawater Heating at Night: Installing seawater heating devices that can operate at night would enable continuous desalination.
  • Geothermal Energy Integration: Exploring the integration of geothermal energy, where available, could further enhance the system's efficiency and reliability.
  • Material Durability: Addressing pipeline corrosion through material selection or improved maintenance strategies is crucial for long-term operation.

Summary updated

Abstract

The paper presents a wind–photovoltaic-thermal hybrid-driven two-stage humidification and dehumidification desalination system for remote island regions lacking access to electricity and freshwater resources. By conducting an analysis of the wind and solar energy resources at the experimental site, a suitable wind power station and photovoltaic power station are constructed. The performance of the wind–solar complementary power generation system is then evaluated based on factors such as output power, seawater desalination load power, battery compensation output, system energy consumption, and water production costs. A variable step gradient disturbance method based on the power–duty ratio is proposed for tracking the maximum power point (MPPT) of wind power generation. The output power of the photovoltaic power generation system is optimized, employing a fuzzy logic control (FLC) method to track the MPPT of photovoltaic power generation. This approach effectively addresses the issues of slow speed and low accuracy encountered by traditional MPPT algorithms in tracking the maximum power point (MPP) of both photovoltaic and wind power generations. In order to ensure that the desalination system can operate stably under different weather conditions, eight working modes are designed, and a programmable logic controller (PLC) is used to control the system, which provides a guarantee for stable water production. Experimental results demonstrate that the system exhibits stable performance, achieving a maximum water output of 80.63 Kg/h and daily water yield is 751.32 Kg, the cost of desalination equipment is 1.4892 USD/t.
BibTeX
@inproceedings{huang2024design,
  author = {Kaijie Huang and Chengjun Qiu and Wenbin Xie and Wei Qu and Yuan Zhuang and Kaixuan Chen and Jiaqi Yan and Gao Huang and Chao Zhang and Jianfeng Hao},
  title = {{Design of a Seawater Desalination System with Two-Stage Humidification and Dehumidification Desalination Driven by Wind and Solar Energy}},
  booktitle = {Water},
  year = {2024},
  doi = {10.3390/w16040609},
}
Figure