Design of a Relay-Free Driving Module for DC Signal Machines in Distributed Railway Systems

Shumin Ge, Meili Xing, Yuyi Wang, Bo HuangAutomation 2026 · DOI

This academic paper, published in Automation, Control and Intelligent Systems, presents a modernized approach to railway signaling by replacing aging electromechanical components with a distributed, all-electronic "relay-free" drive module.

TL;DR

Researchers have developed a distributed, all-electronic drive module for railway DC signal machines that replaces traditional mechanical relays with high-frequency DC-DC conversion. By utilizing a redundant "two-out-of-two" (2oo2) heterogeneous architecture, the system eliminates damaging inrush currents and ensures stable, programmable signaling even across wide fluctuations in input voltage.

What Problem Does This Paper Address?

Traditional railway signaling systems rely on a centralized architecture where control units in a central room are connected to trackside signals via miles of copper cabling. This setup suffers from two major flaws:

  1. Voltage Instability: The extreme length of signal cables causes significant voltage drops and electromagnetic interference, leading to unreliable signal brightness and potential failures.
  2. Relay Degradation: Conventional systems use electromechanical relays to switch power. These relays create "inrush currents"—massive, instantaneous spikes in electricity—and contact arcing. Over time, this damages the signal machines, shortens their lifespan, and drives up maintenance costs.

The authors aim to solve these issues by moving the control logic to the "edge" (trackside) and replacing mechanical switches with precision power electronics.

Methods

The authors designed a Relay-Free Driving Module characterized by several sophisticated engineering choices:

  • Distributed Control: The module is installed trackside, receiving digital commands via a network and generating power locally, which bypasses the problems of long-distance analog cabling.
  • Heterogeneous 2oo2 Architecture: To meet strict "fail-safe" railway standards, the module uses two independent System-on-Chip (SoC) channels. Crucially, these SoCs are from different manufacturers to prevent "common-mode failures" (where a single design flaw or compiler bug might crash both redundant systems simultaneously).
  • Closed-Loop PWM Control: Instead of a simple "on/off" switch, the module uses Pulse Width Modulation (PWM) and high-frequency DC-DC conversion. A feedback loop constantly monitors the output voltage and current, adjusting the PWM in real-time to maintain a steady output.
  • Software-Defined "Soft Start": The FPGA software implements a "slow-on/slow-off" mechanism, gradually ramping up power to eliminate the electrical shock of inrush currents.

Datasets

The researchers did not use external datasets. Instead, they validated the module using a simulated load environment. They collected experimental data by:

  • Varying input voltages from 40V to 244V AC.
  • Testing various PWM duty cycles (25% to 80%) to map the output voltage response.
  • Capturing real-time performance metrics using an oscilloscope connected to a standard 48V DC traffic signal machine.

Key Insights and Ideas

  • Heterogeneity as a Safety Feature: The decision to use different hardware vendors for the dual-channel logic is a high-level safety strategy. It ensures that a hardware-specific vulnerability in one chip won't compromise the entire safety-critical system.
  • Programmability Equals Versatility: Because the output is controlled via software (PWM), a single hardware module can be programmed to drive various types of signal machines with different voltage requirements, simplifying the supply chain for railway operators.
  • Eliminating the "Arc": By moving to an all-electronic design, the physical "sparking" (arcing) of relay contacts is eliminated, which is a primary cause of hardware failure in traditional signaling.

Key Results

  • High Stability: Across a massive input range (40V to 244V), the module maintained a stable output with a calibration factor variation of less than 0.2%, proving the robustness of the closed-loop system.
  • Linear Controllability: The relationship between the PWM duty cycle and output voltage was found to be highly linear, allowing for precise "dimming" or voltage adjustment via software.
  • Successful Load Testing: Experimental results showed a clean, stable 48V / 0.3A output when driving a standard DC signal machine, with no evidence of the damaging current spikes typical of relay-based systems.

Limitations and Future Work

While the laboratory results are promising, the paper notes a few areas for further development:

  • Field Trials: The current study was conducted in a controlled laboratory environment with simulated loads. The authors state that future work must focus on field trials to see how the module handles the harsh electrical and environmental conditions of an actual railway trackside.
  • Long-term Reliability: While the design theoretically extends equipment life, long-term empirical data on component aging in the field is still required to quantify exactly how much maintenance costs will decrease.
  • Environmental Stress: Future iterations will likely need to address extreme temperature fluctuations and vibration resistance inherent to trackside deployments.

Summary updated

Abstract

The centralized control architecture for railway signal drivers often experiences unstable supply voltage and insufficient drive current due to the extended length of signal cables. Furthermore, the high inrush currents during the operation of conventional electromechanical relays can damage signal machines and reduce their service life. To address these issues, this paper presents a relay-free drive module for DC signal machines based on a distributed system. The module integrates remote communication and safety control technologies, enabling the deployment of safety execution units trackside. It utilizes power-driven DC-DC conversion technology, replacing relay-based control circuits to ensure safe driving of DC signals. Based on the "fail-safe"principle, the module incorporates circuit self-testing and closed-loop drive control to guarantee secure and reliable operation. The intelligent control core employs a heterogeneous dual-channel (2oo2) architecture using System-on-Chip (SoC) technology to enhance security and mitigate common-cause failures. Experimental verification confirms that the proposed module delivers highly stable and programmable DC output voltage across a wide input range, demonstrating excellent voltage regulation and controllability via Pulse Width Modulation (PWM). The all-electronic design eliminates contact arcing and inrush current, while integrated real-time monitoring and self-diagnostic capabilities ensure operational safety and reliability. These results underscore the module's strong potential for practical application in modern distributed trackside control systems, offering advantages in system simplification, maintenance reduction, and enhanced equipment longevity.
BibTeX
@inproceedings{ge2026design,
  author = {Shumin Ge and Meili Xing and Yuyi Wang and Bo Huang},
  title = {{Design of a Relay-Free Driving Module for DC Signal Machines in Distributed Railway Systems}},
  booktitle = {Automation},
  year = {2026},
  doi = {10.11648/j.acis.20261401.12},
}

Loading related content...

Figure