Zhiyu Zhao, Qi-Bin Liu, Jiyuan Chen, Jing Chen, Junfeng Chen, Xiang Chen, Changbo Fu, Jun Guo, Kim Siang Khaw, L. Li, S. Li, Danning Liu, K. Liu, Siyuan Song, T. Sun, J. Tang, Yufeng Wang, Zhen Wang, Weihao Wu, Haijun Yang, Yuming Lin, Rui Yuan, Yulei Zhang, Yunlong Zhang, Baihong Zhou, Xuliang Zhu, Y. ZhuarXiv 2024 · DOI · arXiv

Abstract

This paper presents the design and optimization of a LYSO crystal electromagnetic calorimeter (ECAL) for the DarkSHINE experiment, which aims to search for dark photons as potential mediators of dark forces. The ECAL design was evaluated through comprehensive simulations, focusing on optimizing dimensions, material selection, energy distribution, and energy resolution. The ECAL configuration consists of 21$\times$21$\times$11 LYSO crystals, each measuring 2.5$\times$2.5$\times$4 cm$^3$, arranged in a staggered layout to improve signal detection efficiency. A 4 GeV energy dynamic range was established to ensure accurate energy measurements without saturation, which is essential for background rejection and signal identification. A detailed digitization model was developed to simulate the scintillation, SiPM, and ADC behaviors, providing a more realistic representation of detector performance. Additionally, the study assessed radiation damage in the ECAL region, highlighting the necessity of radiation-resistant scintillators and silicon sensors.

Introduction

While gravitational evidence for dark matter is overwhelming, direct detection of dark matter particles remains one of the most significant challenges in modern physics. Traditional searches have focused on the GeV-TeV range, but recent interest has shifted toward the sub-GeV "light dark matter" regime. The DarkSHINE experiment is designed to search for dark photons ($A'$), hypothetical particles that act as a "portal" between the visible world and the dark sector.

When an 8 GeV electron beam strikes a target, dark photons can be produced via "dark bremsstrahlung." Since these dark photons decay into invisible dark matter, the experimental signature is a significant amount of "missing" energy. Detecting this signature requires an electromagnetic calorimeter (ECAL) with exceptional precision, high-speed readout, and robust radiation hardness.

Experimental Design and Methodology

The DarkSHINE detector system is a multi-layered apparatus designed to track and measure particles with high fidelity. The layout includes a magnet, silicon trackers, a tungsten target, the ECAL, and a hadronic calorimeter (HCAL).

Schematic layout of the DarkSHINE detector components.

Material and Geometry Optimization

Researchers selected LYSO (Lutetium-Yttrium Oxyorthosilicate) crystals for the ECAL. LYSO is ideal for high-intensity experiments due to its high light yield and fast decay time (~40 ns), which minimizes "pile-up" at the expected 10 MHz event rate. The final optimized configuration utilizes a $21\times21\times11$ array (4,851 crystals total). To prevent particles from escaping through inter-crystal gaps, the researchers implemented a staggered layout where successive layers are shifted by half a crystal's width.

Full-Chain Digitization

To move beyond idealized "truth" energy simulations, the study developed a realistic digitization model using the Geant4-based DarkSHINE Software (DSS) framework. This model accounts for:

  1. Scintillation: Photon statistics and attenuation within the crystal.
  2. SiPM (Silicon Photomultiplier): Photon detection efficiency, pixel saturation, and crosstalk.
  3. ADC (Analog-to-Digital Converter): A multi-gain electronic system (high, medium, and low gain) providing a 4 GeV dynamic range per channel to prevent detector blinding during high-energy background events.

Results and Performance

The simulation results confirm that the ECAL design meets the stringent requirements of the DarkSHINE experiment. The statistical term of the energy resolution is better than 2%, providing the sensitivity needed to identify missing energy signatures.

Total energy distribution in the ECAL for signal and background.

As shown in the energy distribution, the signal events (representing various dark photon masses) are clearly distinguishable from the "inclusive" Standard Model background, which typically deposits nearly the full beam energy in the ECAL. By applying a 4 GeV trigger threshold, the system can filter out over 99.9% of inclusive backgrounds while maintaining high efficiency for the dark photon signal.

Furthermore, radiation resilience assessments indicate that the central crystals will face a Total Ionizing Dose (TID) of $10^7$ rad over one year. LYSO is expected to maintain its performance under these conditions, and the calculated Non-Ionizing Energy Loss (NIEL) in silicon sensors ($10^{13}$ $n_{eq}/\text{cm}^2$) provides a clear benchmark for readout electronics design.

Conclusion

The finalized design for the DarkSHINE ECAL provides a robust foundation for the search for light dark matter. Future work will focus on the engineering challenges of calibrating nearly 5,000 channels to 1% accuracy and implementing an online trigger system capable of handling the 10 MHz beam. Experimental validation through beam tests of prototype units is the next critical step in realizing the DarkSHINE mission.

Summary updated

Abstract

This paper presents the design and optimization of a LYSO crystal electromagnetic calorimeter (ECAL) for the DarkSHINE experiment, which aims to search for dark photons as potential mediators of dark forces. The ECAL design was evaluated through comprehensive simulations, focusing on optimizing dimensions, material selection, energy distribution, and energy resolution. The ECAL configuration consists of 21$\times$21$\times$11 LYSO crystals, each measuring 2.5$\times$2.5$\times$4 cm$^3$, arranged in a staggered layout to improve signal detection efficiency. A 4 GeV energy dynamic range was established to ensure accurate energy measurements without saturation, which is essential for background rejection and signal identification. A detailed digitization model was developed to simulate the scintillation, SiPM, and ADC behaviors, providing a more realistic representation of detector performance. Additionally, the study assessed radiation damage in the ECAL region, highlighting the necessity of radiation-resistant scintillators and silicon sensors.
BibTeX
@misc{zhao2024design,
  author = {Zhiyu Zhao and Qi-Bin Liu and Jiyuan Chen and Jing Chen and Junfeng Chen and Xiang Chen and Changbo Fu and Jun Guo and Kim Siang Khaw and L. Li and S. Li and Danning Liu and K. Liu and Siyuan Song and T. Sun and J. Tang and Yufeng Wang and Zhen Wang and Weihao Wu and Haijun Yang and Yuming Lin and Rui Yuan and Yulei Zhang and Yunlong Zhang and Baihong Zhou and Xuliang Zhu and Y. Zhu},
  title = {{Design of a LYSO Crystal Electromagnetic Calorimeter for DarkSHINE Experiment}},
  year = {2024},
  eprint = {2407.17800},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2407.17800},
}
Figure