Abstract
For robot assisted surgery under magnetic resonance imaging (MRI) guidance, constraints such as material limits, actuation method limits and available sensor limits have made the design and control of an actuation and transmission system the most challenging problem. Aiming at tackling the aforementioned issues, this paper proposes a novel pneumatic powered motor, which features few as two inputs, continuous and back-drivable motion outputs, integrated MRI-compatible speed sensor, compact modularly switchable downspeed components, and fast additively manufacture ability (22 components in total). It promisingly fills the gap between the current MRI-compatible surgical robots and available actuation methods and offers an alternative approach for the community to actuate various surgical robotic platforms. Detailed design methods for the pneumatic motor and integrated rotary encoder are developed first. Motor performances are experimentally evaluated next to analyse and demonstrate its characteristics under various pressures against different load torques. Finally, the proposed pneumatic motor is compared with recent MRI-compatible pneumatic actuators, illustrating the feasibility of the proposed fluid power motor for actuations of MRI surgical robots.
Introduction
Operating a robot inside an MRI scanner is a significant engineering challenge. The massive magnetic field prohibits the use of ferromagnetic materials and standard electric motors, which generate electromagnetic interference (EMI) that ruins image quality. While pneumatic (air-powered) actuators are a natural fit for this environment, existing designs often fall into two camps: they are either complex, multi-part "stepper" motors that move in jerky increments, or simple turbines that lack the torque necessary for surgical tasks like needle insertion. There is a pressing need for a high-torque, continuous-motion actuator that is easy to manufacture and doesn't require expensive, specialized components.
Design and Methodology
The authors propose a novel design focused on additive manufacturing (3D printing) and mechanical simplicity. The motor utilizes a modified Pelton turbine for actuation. By supplying air to one of two inlet ports, the motor achieves bidirectional rotation. To convert high-speed turbine rotation into high-torque output, the design integrates a "strain wave gear" (harmonic drive) with a 1:40 reduction ratio.
Crucially, the flex spline—the component that must deform to transmit motion—is 3D printed using Thermoplastic Polyurethane (TPU), a flexible polymer. This allows for a massive reduction ratio in a very small footprint without precision-machined metal parts. To track speed without electronics, an integrated optical rotary encoder was developed. Two fiber optic cables are positioned near the shaft; a cutout in the shaft cyclically blocks the light beam, creating binary pulses converted into speed data far away from the MRI's magnetic bore. The entire assembly consists of only 22 components, enabling rapid production and assembly.
Experimental Results
The prototype measures just 60mm x 40mm x 40mm. Performance benchmarks were established through speed validation against a commercial laser tachometer and load characterization using a magnetic particle brake to simulate resistive torques.
The motor behaves linearly, with speed and torque showing a nearly linear relationship with input pressure ($R^2 > 0.98$), facilitating easier modeling and control. The integrated optical encoder showed an error of less than 2% for speeds above 300 rpm. The motor achieved a maximum torque of 170 mNm and a power output of 0.14W. In closed-loop tests, the motor successfully performed a 5-revolution step response with a resolution of 4.5 degrees.
Conclusion
The use of 3D-printed TPU for a harmonic drive flex spline drastically lowers the barrier to entry for custom surgical robotics. While 3D printing introduces higher internal friction due to surface roughness, the motor's performance is sufficient for the "slow and steady" requirements of many surgical procedures. Future work will focus on optimizing gear ratios, exploring different 3D-printable materials to reduce friction, and testing the system with longer air hoses to simulate clinical environments.