Design and Experimental Study of a Prefabricated Building Thermoelectric Power Generation–Wall System for Severe Cold Climates

Zhanguo Hao, Ran Hu, Yi Gao, Jinyuan Liu, Xiaoming SuBuildings 2025

TL;DR

This paper introduces a novel thermoelectric power generation-wall (TEPG-Wall) system designed for prefabricated buildings in severe cold climates. By leveraging the temperature difference between indoor and outdoor environments using Ni90Cr10-Ni45Cu55 thermoelectric material, the system aims to enhance building energy self-sufficiency. While the current output is modest, it's sufficient for low-power applications and demonstrates a promising avenue for sustainable building design in challenging climates.

What Problem Does This Paper Address?

Buildings in severe cold climates face immense energy demands for heating, straining energy supplies and environmental sustainability. Conventional insulation and energy utilization strategies often fall short of achieving optimal efficiency and energy conservation. The authors address this by proposing a system that actively generates electricity from the inherent temperature gradients present in building envelopes, particularly in regions with harsh winters. This approach aims to reduce reliance on external energy sources and contribute to overall building energy self-sufficiency.

Methods

The study employs a dual approach of software simulation using COMSOL Multiphysics 6.1 and experimental validation.

  • Simulation: A 3D steady-state model was developed, incorporating material thermal and electrical properties, and building structural configurations. The simulation focused on heat transfer, electrical conductivity, and thermoelectric power generation principles, using temperature data from the Hohhot region as boundary conditions.
  • Experimentation: A TEPG-Wall system prototype was constructed and tested in an environmental chamber. This chamber allowed for controlled cycling of indoor and outdoor temperatures to simulate summer, winter, and transitional seasons. High-precision multimeters and an intelligent temperature controller were used for data acquisition. The experimental setup involved arranging 15 TEPG units in parallel within the wall's insulation layer.

Datasets

The study utilized temperature data from the Hohhot region in China for simulation boundary conditions. For experimental validation, data was collected over multiple cycles during summer, winter, and transitional seasons. The paper includes detailed experimental result data in Appendices A, B, and C, covering external and internal cabin/cavity temperatures, temperature differences, voltage, and current.

Key Insights and Ideas

  • Harnessing the Temperature Gradient: The core innovation is the direct integration of thermoelectric generators into the building wall structure to exploit the indoor-outdoor temperature difference, a readily available resource in cold climates.
  • Material Choice Matters: The selection of Ni90Cr10-Ni45Cu55 thermoelectric material is crucial. It offers a cost-effective, stable, and mechanically sound alternative to more expensive and brittle materials like Bi2Te3, making it suitable for large-scale construction applications.
  • Seasonal Performance Variation: The system's power generation is highly dependent on the season, with winter yielding the highest output due to larger temperature differentials. This highlights the importance of considering seasonal climate variations in system design and performance estimation.
  • Low-Power Application Viability: While the current power output is modest (0.02 W average, 0.0586 kWh annually per 15 devices), it's deemed sufficient for powering low-power building equipment, suggesting potential for distributed energy generation within buildings.
  • Design Optimization Potential: The study identifies that while the collector cavity design enhances heat absorption, further optimization of the structure and heat-absorbing materials is needed to improve efficiency.

Key Results

  • Annual Energy Output: The system, with 15 parallel thermoelectric devices, achieved an average annual power generation of approximately 0.0586 kWh.
  • Average Output Power: The average thermoelectric output power was approximately 0.02 W.
  • Summer Performance: A maximum voltage of ~0.3 V and power of ~0.012 W were observed with a temperature difference of ~55 °C.
  • Winter Performance: With a temperature difference of ~51 °C, the system achieved a maximum voltage of ~0.5 V and power of ~0.037 W.
  • Transition Season Performance: A maximum voltage of ~0.28 V and power of ~0.0065 W were recorded with a temperature difference of ~34 °C.
  • Simulation vs. Experiment: The study found that simulated data closely aligned with experimental measurements, confirming the reliability of the modeling approach.

Limitations and Future Work

  • Low Power Output: The current power generation capacity is limited, suitable only for low-power devices. The authors acknowledge this and suggest that future research should focus on developing advanced thermoelectric materials to enhance conversion efficiency.
  • System Optimization: Further optimization of the system design, including improved thermoelectric module configurations, enhanced cavity structures, and better integration with building envelopes, is recommended.
  • Dynamic and Long-Term Performance: The study calls for extensive research into the dynamic and long-term performance of the system across diverse climatic conditions to establish accurate predictive models.
  • Experimental Errors: The authors note that experimental errors were observed, primarily attributed to environmental simulation conditions, instrument precision, and thermal resistance during installation.
  • Peltier Effect Utilization: The potential for the TEPG-Wall System to reduce indoor air conditioner energy consumption via the Peltier effect was noted but not investigated due to space limitations. This is identified as a future research direction.

Summary updated

BibTeX
@inproceedings{hao2025design,
  author = {Zhanguo Hao and Ran Hu and Yi Gao and Jinyuan Liu and Xiaoming Su},
  title = {{Design and Experimental Study of a Prefabricated Building Thermoelectric Power Generation–Wall System for Severe Cold Climates}},
  booktitle = {Buildings},
  year = {2025},
  doi = {10.3390/buildings15071076},
}
Figure