Design and construction of the MicroBooNE detector

R. Acciarri, C. Adams, R. An, A. Aparicio, S. Aponte, J. Asaadi, M. Auger, Nadine Ayoub, L. Bagby, B. Baller, R. Barger, G. Barr, M. Bass, F. Bay, K. Biery, M. Bishai, A. Blake, V. Bocean, D. Boehnlein, V.d. Bogert, T. Bolton, L. Bugel, C. Callahan, L. Camilleri, D. Caratelli, B. Carls, R. Castillo Fernández, F. Cavanna, S. Chappa, H. Chen, Kai Chen, C.y. Chi, Christie Chiu, E. Church, D. Cianci, G. H. Collin, J. M. Conrad, M. R. Convery, J. Cornele, P. L. Cowan, J. I. Crespo-Anadón, G. Crutcher, Félix Darve, Raymond J. Davis, M. Del Tutto, D. Devitt, S. Duffin, S. Dytman, B. Eberly, A. Ereditato, David Erickson, L. Escudero, J. Esquivel, Syed Muhammad Yousaf Farooq, J. Farrell, D. Featherston, B. T. Fleming, W. Foreman, A. P. Furmanski, V. Genty, M. Geynisman, D. Goeldi, B. Goff, S. Gollapinni, N. Graf, E. Gramellini, J. Green, Austen T. Greene, H. Greenlee, T. Griffin, R. Grosso, R. Guénette, A. Hackenburg, Rolf Haenni, P. Hamilton, P. Healey, O. Hen, Elizabeth Henderson, J. Hewes, Colton Hill, Kurt Keys Hill, Logan Himes, J. Ho, G. A. Horton-Smith, David L. Huffman, C. Ignarra, C. James, E. James, J. Jan de Vries, W. Jaskierny, C.-m. Jen, L. Jiang, B.l. Johnson, M. Johnson, R. A. Johnson, B. J. P. Jones, J. Joshi, H. Jöstlein, D. Kaleko, Leonidas KalousisJournal of Instrumentation 2017 · DOI

TL;DR

This paper details the design and construction of the MicroBooNE detector, a large liquid argon time projection chamber (LArTPC) at Fermilab. It addresses the challenge of building and operating such a complex detector with unprecedented precision for neutrino physics, paving the way for future large-scale LArTPC experiments.

What Problem Does This Paper Address?

Neutrino physics experiments aim to understand fundamental properties of neutrinos, such as their mass and interactions. Liquid argon time projection chambers (LArTPCs) offer a powerful technology for this, providing excellent spatial resolution and calorimetry. However, building and operating these detectors at the scale required for precision measurements presents significant engineering challenges. These include maintaining ultra-pure liquid argon over long periods, handling cryogenic temperatures, developing low-noise electronics capable of detecting faint signals, and ensuring precise alignment of detector components. MicroBooNE, as a key experiment in the Short Baseline Neutrino (SBN) program, needed to overcome these hurdles to achieve its physics goals, particularly in addressing the MiniBooNE low-energy excess anomaly and performing precision cross-section measurements.

Methods

The paper meticulously describes the design and construction of the MicroBooNE detector, covering its various subsystems:

  • Cryogenic System: A sophisticated system for maintaining ultra-pure liquid argon at cryogenic temperatures (87 K) and controlling temperature gradients (<0.1 K) to ensure electron drift uniformity. This includes a large stainless steel cryostat, an argon purification subsystem with molecular sieve and copper filters, and a liquid nitrogen refrigeration system.
  • LArTPC Detector: The core of the experiment, featuring a cathode, field cage, and three anode planes with precisely wound wires. The design emphasizes uniformity of the electric field and minimizing outgassing materials.
  • Light Collection System: A primary system of 32 optical units (PMTs behind wavelength-shifting plates) and a secondary system of four lightguide paddles for detecting scintillation light. This system is crucial for triggering and event reconstruction.
  • Electronics and Readout Systems: Custom cryogenic low-noise front-end electronics (CMOS ASICs on cold motherboards) are located inside the cryostat to minimize noise. These are connected to warm electronics for amplification, digitization (ADC/FEM modules), and data processing.
  • Infrastructure and Monitoring: Extensive systems for AC/DC power distribution, grounding, interlocks, and slow monitoring (EPICS) are implemented to ensure a stable and safe operating environment, crucial for low-noise data acquisition.
  • UV Laser System: A sophisticated system for generating precise ionization tracks within the detector to calibrate electric field distortions and map space charge effects.

Datasets

Not discussed in the paper. The paper focuses on the design and construction of the detector itself, rather than the data collected from it.

Key Insights and Ideas

  • Cryogenic Electronics are Key: Placing front-end electronics inside the cryostat is essential for minimizing noise and achieving the required sensitivity for LArTPCs.
  • Purity is Paramount: Maintaining extremely high purity of liquid argon (below 100 ppt O2 equivalent) is critical for long electron drift paths, directly impacting the detector's performance.
  • Integrated Design for Reliability: The careful integration of various subsystems, from cryogenics to electronics and safety interlocks, is crucial for the long-term, stable operation of such a large and complex detector.
  • Laser Calibration for Precision: The UV laser system is a novel approach to precisely map electric field distortions, which are vital for accurate track reconstruction in LArTPCs.
  • Minimizing Noise Sources: A multi-faceted approach to grounding, shielding, and clean power distribution is implemented to combat electromagnetic interference.

Key Results

The paper reports on the successful design, construction, and assembly of the MicroBooNE detector. Key aspects include:

  • Cryostat: A 12.2 m long, 3.81 m diameter cryostat capable of holding 170 tonnes of liquid argon.
  • LArTPC: A 90-tonne active volume with 8256 wires, designed for a drift field of 500 V/cm.
  • Electronics: 8,256 readout channels instrumented with custom cryogenic CMOS ASICs.
  • Light Collection: 32 optical units providing 0.9% photocathode coverage.
  • Cryogenic System: Capable of maintaining argon purity below 100 ppt O2 equivalent and a temperature gradient of less than 0.1 K.
  • High Voltage: A nominal cathode voltage of -128 kV is applied.
  • UV Laser System: Two lasers are implemented for comprehensive drift field calibration.

The paper details the rigorous testing and quality assurance procedures for all components, ensuring their suitability for the demanding cryogenic and high-purity environment.

Limitations and Future Work

The paper focuses on the design and construction, so limitations are primarily related to the engineering and implementation challenges. The authors acknowledge that:

  • Space Charge Effects: Non-uniformities in the electric field due to space charge are a known challenge that the UV laser system aims to address.
  • PMT Gain Stability: Some PMTs exhibited unexpected gain behavior at cryogenic temperatures, requiring careful characterization and calibration.
  • TPB Degradation: TPB coatings for wavelength shifting are vulnerable to UV exposure, necessitating careful handling and protection during construction.

Future work, as implied by the paper's context within the SBN program, will involve utilizing this meticulously constructed detector to achieve its physics goals, including addressing the MiniBooNE anomaly and performing precision neutrino cross-section measurements. The detailed design and construction described here serve as a foundation for future large-scale LArTPC experiments like DUNE.

Summary updated

Abstract

This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline Neutrino program, located at Fermilab, and will utilize the capabilities of liquid argon detectors to examine a rich assortment of physics topics. In this document details of design specifications, assembly procedures, and acceptance tests are reported.
BibTeX
@article{acciarri2017design,
  author = {R. Acciarri and C. Adams and R. An and A. Aparicio and S. Aponte and J. Asaadi and M. Auger and Nadine Ayoub and L. Bagby and B. Baller and R. Barger and G. Barr and M. Bass and F. Bay and K. Biery and M. Bishai and A. Blake and V. Bocean and D. Boehnlein and V.D. Bogert and T. Bolton and L. Bugel and C. Callahan and L. Camilleri and D. Caratelli and B. Carls and R. Castillo Fernández and F. Cavanna and S. Chappa and H. Chen and Kai Chen and C.Y. Chi and Christie Chiu and E. Church and D. Cianci and G. H. Collin and J. M. Conrad and M. R. Convery and J. Cornele and P. L. Cowan and J. I. Crespo-Anadón and G. Crutcher and Félix Darve and Raymond J. Davis and M. Del Tutto and D. Devitt and S. Duffin and S. Dytman and B. Eberly and A. Ereditato and David Erickson and L. Escudero and J. Esquivel and Syed Muhammad Yousaf Farooq and J. Farrell and D. Featherston and B. T. Fleming and W. Foreman and A. P. Furmanski and V. Genty and M. Geynisman and D. Goeldi and B. Goff and S. Gollapinni and N. Graf and E. Gramellini and J. Green and Austen T. Greene and H. Greenlee and T. Griffin and R. Grosso and R. Guénette and A. Hackenburg and Rolf Haenni and P. Hamilton and P. Healey and O. Hen and Elizabeth Henderson and J. Hewes and Colton Hill and Kurt Keys Hill and Logan Himes and J. Ho and G. A. Horton-Smith and David L. Huffman and C. Ignarra and C. James and E. James and J. Jan de Vries and W. Jaskierny and C.-M. Jen and L. Jiang and B.L. Johnson and M. Johnson and R. A. Johnson and B. J. P. Jones and J. Joshi and H. Jöstlein and D. Kaleko and Leonidas Kalousis},
  title = {{Design and construction of the MicroBooNE detector}},
  journal = {Journal of Instrumentation},
  year = {2017},
  doi = {10.1088/1748-0221/12/02/p02017},
}
Figure