Denoising Method of a Power Quality Signal Based on Parameter Coordination of Membership Function in Fuzzy Logic Theory

Ruotian Yao, Hao Bai, Yifan Zhang, Baoyi Cen, Hongbo ZouProcesses 2025

TL;DR

This paper introduces a novel fuzzy logic-based method for denoising power quality signals. By intelligently coordinating membership function parameters and using a set of seven masks, the method effectively smooths out noise while crucially preserving important signal anomalies like abrupt changes, outperforming traditional filtering techniques.

What Problem Does This Paper Address?

Modern electrical grids are increasingly complex, leading to a rise in power quality issues such as harmonics, voltage fluctuations, and transients. Accurate analysis of these issues is vital for grid stability and equipment longevity. A critical first step in this analysis is denoising the collected power quality signals, which are often contaminated by various types of noise. Traditional denoising methods, like mean and median filtering, struggle with preserving transient or "mutation" points in the signal, which are crucial for identifying fault types and timings. Wavelet transforms offer better time-frequency localization but can be computationally intensive and less effective in noisy environments. This paper aims to bridge this gap by proposing a denoising method that effectively smooths noise while retaining the integrity of critical signal features.

Methods

The proposed denoising method leverages fuzzy logic theory with a novel approach to parameter coordination. The core steps are:

  1. Mask Design: Seven distinct "masks" (templates) of varying point configurations are designed to capture different aspects of the power quality signal sequence. These masks are applied to the signal, with each mask focusing on a specific window of data points around a central point.
  2. Membership Degree Calculation: For each point in the signal, fuzzy logic is used to calculate its "membership degree" to each of the seven masks. This degree quantifies how well the signal point fits the pattern represented by each mask.
  3. Input to Fuzzy Logic: The average value of the signal points within each of the seven masks is calculated. These averages, along with the calculated membership degrees, serve as inputs to the fuzzy logic system.
  4. Parameter Coordination: A key innovation is the harmonious design and coordination of the boundary parameters within the fuzzy logic's membership functions for both input and output variables. This coordination aims to maximize the utilization of the power signal's information.
  5. Denoising Output: Based on the fuzzy logic inference and the coordinated parameters, the algorithm determines the denoised value for each signal point. The method prioritizes masks with higher membership degrees, effectively using them to guide the denoising process.

The paper also details the fuzzification process, using triangular membership functions for inputs and outputs, and explains how parameters are coordinated to achieve optimal results.

Datasets

The paper does not introduce new datasets. Instead, it uses simulated power quality signals to evaluate its proposed method. These simulated signals include:

  • Voltage Sag Signal: A single-phase voltage signal with a 20% sag and a 60-degree phase jump, corrupted by Gaussian white noise (mean=0, variance=0.06).
  • Voltage Interruption Signal: A single-phase voltage signal experiencing a phase jump, voltage sag, and a short-term interruption, also corrupted by Gaussian white noise.

The performance of the proposed method is compared against several traditional and fuzzy-based filtering techniques using these simulated scenarios.

Key Insights and Ideas

  • Fuzzy Logic for Signal Integrity: The paper demonstrates that fuzzy logic, when applied with careful parameter coordination, can be a powerful tool for signal denoising, particularly when preserving signal anomalies is critical.
  • Masks as Feature Extractors: The design of seven specific masks acts as a novel way to extract local signal features and patterns, which are then fed into the fuzzy logic system. This is more sophisticated than simple windowing.
  • Parameter Coordination is Crucial: The emphasis on harmoniously coordinating membership function parameters for both inputs and outputs is highlighted as a key factor in achieving superior denoising performance and retaining signal details.
  • The 1x7 Template Advantage: The study specifically found that a 1x7 template (seven points) for mask design provided the best balance between noise smoothing and mutation point preservation, outperforming smaller (1x3, 1x5) and larger (1x9) templates.

Key Results

The proposed method demonstrated superior performance in both denoising effectiveness (measured by Signal-to-Noise Ratio, SNR) and the preservation of mutation points (measured by the difference between denoised and ideal amplitudes, denoted by λ).

  • Voltage Sag Signal:
    • The proposed method achieved the highest SNR of 27.5183 dB, significantly outperforming traditional mean filtering (22.9976 dB) and median filtering (23.2964 dB), as well as other fuzzy-based methods.
  • It also yielded the smallest λ values for mutation points (e.g., 15.2283% for Mutation Point 1), indicating the denoised amplitude was closest to the ideal signal.
  • Voltage Interruption Signal:
    • The proposed method again achieved the highest SNR of 31.2368 dB.
  • It also produced the smallest λ values for mutation points (e.g., 7.3149% for Mutation Point 1).

The paper concludes that the proposed method is more suitable for denoising power quality signals compared to traditional filtering methods.

Limitations and Future Work

  • Computational Complexity: While not explicitly detailed as a limitation, the use of multiple masks and fuzzy logic inference implies a certain level of computational overhead. The paper mentions that WT operations can be complex and slow, suggesting that efficiency might be a consideration.
  • Generalizability: The study focuses on specific power quality disturbances (voltage sag, interruption) and Gaussian white noise. Further research could explore its effectiveness on a wider range of noise types and power quality phenomena.
  • Parameter Optimization: While parameter coordination is a key contribution, the optimal selection of the number of masks and their specific configurations might require further investigation for different signal characteristics.

The authors suggest that the proposed method can be applied to related filters and power quality monitoring devices, implying a direct path for practical implementation and further development in these areas.

Summary updated

Abstract

Considering the characteristics of power quality signals and denoising requirements, a denoising method of a power quality signal based on parameter coordination of membership function in fuzzy logic theory is proposed in this paper. First of all, for the signal sequence of power quality, seven masks are designed to make the best use of the signal sequence information. Secondly, based on fuzzy logic theory, the corresponding membership degrees are calculated for these seven masks, and the average value of all points in these masks is used as the input of fuzzy logic theory. Then, according to the membership function of the input and output variable, the boundary parameters are designed harmoniously to obtain the best denoising effect. Finally, based on the experimental simulation results, it is proved that the proposed method can not only smooth the noise well, but also keep the information for the abrupt point in its entirety, which is more suitable for denoising power quality signals compared with the traditional filtering method.
BibTeX
@inproceedings{yao2025denoising,
  author = {Ruotian Yao and Hao Bai and Yifan Zhang and Baoyi Cen and Hongbo Zou},
  title = {{Denoising Method of a Power Quality Signal Based on Parameter Coordination of Membership Function in Fuzzy Logic Theory}},
  booktitle = {Processes},
  year = {2025},
  doi = {10.3390/pr13030738},
}
Figure