Defect Localization Using Time-Resolved Photon Emission on SOI Devices that Fail Scan Tests
Abstract
Abstract Time-resolved photon emission has been shown to be useful in analyzing clock skews and timing-related defects in flip-chip devices. In practice, time-resolved photon emission using the S-25 Quantar detector cannot be used at long loop lengths (typically >10 μs). This paper discusses a near-infrared (NIR) optimized time-resolved emission system to demonstrate that even with long loop lengths time-resolved photon emission can be extremely useful for defect localization. Specifically, it describes time-resolved photon emission system, and shows how time-resolved photon emission was used to solve two different issues that caused scan fails on silicon-on-insulator devices, and briefly discusses the interpretation of optical waveforms. The two issues are presented as case studies.
BibTeX
@inproceedings{bodoh2002defect,
author = {Dan Bodoh and Ed Black and Kris Dickson and Wang Ron and Kwang‐Ting Cheng and N. Pakdaman and Jim Vickers and Dan Cotton and Birk Lee},
title = {{Defect Localization Using Time-Resolved Photon Emission on SOI Devices that Fail Scan Tests}},
booktitle = {Proceedings - International Symposium for Testing and Failure Analysis},
year = {2002},
doi = {10.31399/asm.cp.istfa2002p0655},
}Ask Althea to put this paper to the test.