Deep-learning system to improve the quality and efficiency of volumetric heart segmentation for breast cancer

Roman Zeleznik, Jakob Weiss, Jana Taron, Christian V. Guthier, Danielle S. Bitterman, Cindy Hancox, Benjamin H. Kann, Daniel W. Kim, Rinaa S. Punglia, Jeremy Bredfeldt, Borek Foldyna, Parastou Eslami, Michael T. Lu, Udo Hoffmann, Raymond H. Mak, Hugo J. W. L. AertsNpj Digit. Medicine 2021 · OpenReview

TL;DR

This paper demonstrates that a deep learning system for heart segmentation, initially developed for cardiovascular radiology, can be effectively transferred to radiation oncology for breast cancer treatment planning. The system significantly reduces segmentation time and improves inter-expert agreement, while maintaining high accuracy, suggesting a powerful paradigm for knowledge dissemination in medicine.

What Problem Does This Paper Address?

The rapid growth of medical knowledge leads to increasing sub-specialization, making it difficult for any single practitioner to master all areas. This creates a disparity in access to highly specialized expertise, particularly in resource-limited settings. In radiation oncology, accurate segmentation of organs at risk (OARs) on CT scans is crucial for treatment planning, but manual segmentation is time-consuming and prone to variability. The heart, in particular, is a critical OAR for breast cancer patients, as radiation exposure can lead to adverse cardiac events. This paper addresses the challenge of disseminating specialized cardiovascular imaging expertise to improve the efficiency and accuracy of heart segmentation in breast cancer radiation oncology, thereby potentially reducing healthcare disparities.

Methods

The core of this work is a 3D deep learning system, based on the U-Net architecture, developed for volumetric heart segmentation. The system was initially trained on a multi-center dataset of cardiac CT scans from cardiovascular radiology. This "expert knowledge" was then transferred to radiation oncology without retraining. The study employed a two-pronged validation approach:

  1. Prospective Clinical Assessment: Eight radiation oncology experts segmented the heart in 20 breast cancer CT scans, first manually and then with AI assistance. This allowed for the assessment of segmentation time, inter-expert agreement (using Dice scores), and anatomical accuracy.
  2. Real-World Validation: The system's performance was evaluated on a large, independent dataset of 5677 breast cancer patients treated with radiation therapy. This involved comparing the AI-generated segmentations to the clinically approved, manually created segmentations used for treatment delivery.

Datasets

  • Training Data: Multi-center dataset of 858 CT scans (including Framingham Heart Study, PROMISE, and NLST cohorts) with manual heart segmentations provided by cardiovascular radiologists.
  • Validation Data:
    • Prospective Cohort: 20 breast cancer patients' CT scans for direct comparison of human vs. AI-assisted segmentation.
  • Real-World Cohort: 5677 breast cancer patients' CT scans treated with radiation therapy at the Dana-Farber/Brigham and Women's Cancer Center between 2008–2018.

Key Insights and Ideas

  • Domain Transferability of AI Expertise: The most significant insight is the successful transfer of a deep learning system's expertise from one medical specialty (cardiovascular radiology) to another (radiation oncology) without the need for retraining. This highlights the potential of AI to act as a conduit for disseminating specialized knowledge.
  • Human-AI Partnership for Efficiency and Quality: The study demonstrates that a human-AI partnership can significantly improve both the efficiency (reduced time) and consistency (increased agreement) of a complex medical task like OAR segmentation.
  • AI as a Tool for Reducing Disparities: By automating and standardizing segmentation, the AI system has the potential to democratize access to high-quality treatment planning, especially in undersupplied regions where expert radiologists or dosimetrists may be scarce.
  • Robustness to Data Variability: The AI system performed well even when applied to data with different acquisition protocols, scanner types, and image quality (e.g., non-gated vs. ECG-gated scans), suggesting a high degree of robustness.
  • Potential for AI-Only Segmentation: The finding that AI-only segmentations showed no significant difference in accuracy compared to manual or AI-assisted segmentations is a crucial step towards potentially fully automated OAR segmentation in the future.

Key Results

  • Time Reduction: AI-assisted segmentation reduced the time required by experts by 50% (from a median of 4.0 min to 2.0 min).
  • Improved Agreement: Inter-expert agreement significantly increased with AI assistance, with a median Dice score of 0.97 compared to 0.95 for manual segmentation.
  • High Accuracy: Expert accuracy was similar with and without AI assistance (median Dice 0.92), and not significantly different from AI-only segmentations.
  • Real-World Concordance: The system achieved a high median Dice score of 0.89 across 5677 real-world patient cases.
  • Reduced Failure Rate: The AI system demonstrated a significantly lower failure rate (defined as Dice < 0.85) compared to historical clinical segmentations, with a decrease from 46.7% to 5.6% over the study period.
  • Qualitative Improvement: In a subset of failed cases, the AI segmentations were rated as "excellent" in 62.2% of instances, compared to only 15.7% for clinical segmentations, which were often rated as "fair" (70.6%).

Limitations and Future Work

  • Time Measurement: The time for segmentation was self-recorded by medical experts, which could introduce inaccuracies.
  • Whole Heart Segmentation Only: The current system segments the entire heart. The authors note that cardiac substructures are increasingly recognized as important for toxicity prediction, suggesting future work on segmenting these finer structures.
  • Lack of Dose Calculation/Treatment Plan Analysis: The study focused on segmentation accuracy and efficiency, not on the downstream impact on radiation dose calculations or treatment plan optimization.
  • Supine Position Only: The current system is trained on data from patients in the supine position, limiting its application to other patient orientations.

Future work could involve extending the system to segment cardiac substructures, integrating it into dose calculation workflows, and adapting it for different patient positions. The authors also suggest that the robustness of the system opens doors for its implementation in undersupplied hospitals.

Summary updated

Abstract

Although artificial intelligence algorithms are often developed and applied for narrow tasks, their implementation in other medical settings could help to improve patient care. Here we assess whether a deep-learning system for volumetric heart segmentation on computed tomography (CT) scans developed in cardiovascular radiology can optimize treatment planning in radiation oncology. The system was trained using multi-center data (n = 858) with manual heart segmentations provided by cardiovascular radiologists. Validation of the system was performed in an independent real-world dataset of 5677 breast cancer patients treated with radiation therapy at the Dana-Farber/Brigham and Women’s Cancer Center between 2008–2018. In a subset of 20 patients, the performance of the system was compared to eight radiation oncology experts by assessing segmentation time, agreement between experts, and accuracy with and without deep-learning assistance. To compare the performance to segmentations used in the clinic, concordance and failures (defined as Dice &lt; 0.85) of the system were evaluated in the entire dataset. The system was successfully applied without retraining. With deep-learning assistance, segmentation time significantly decreased (4.0 min [IQR 3.1–5.0] vs. 2.0 min [IQR 1.3–3.5]; p &lt; 0.001), and agreement increased (Dice 0.95 [IQR = 0.02]; vs. 0.97 [IQR = 0.02], p &lt; 0.001). Expert accuracy was similar with and without deep-learning assistance (Dice 0.92 [IQR = 0.02] vs. 0.92 [IQR = 0.02]; p = 0.48), and not significantly different from deep-learning-only segmentations (Dice 0.92 [IQR = 0.02]; p ≥ 0.1). In comparison to real-world data, the system showed high concordance (Dice 0.89 [IQR = 0.06]) across 5677 patients and a significantly lower failure rate (p &lt; 0.001). These results suggest that deep-learning algorithms can successfully be applied across medical specialties and improve clinical care beyond the original field of interest.
BibTeX
@inproceedings{zeleznik2021deep,
  author = {Roman Zeleznik and Jakob Weiss and Jana Taron and Christian V. Guthier and Danielle S. Bitterman and Cindy Hancox and Benjamin H. Kann and Daniel W. Kim and Rinaa S. Punglia and Jeremy Bredfeldt and Borek Foldyna and Parastou Eslami and Michael T. Lu and Udo Hoffmann and Raymond H. Mak and Hugo J. W. L. Aerts},
  title = {{Deep-learning system to improve the quality and efficiency of volumetric heart segmentation for breast cancer}},
  booktitle = {Npj Digit. Medicine},
  year = {2021},
  url = {https://openreview.net/forum?id=3DEpLITi7t},
}
Figure