Deep Learning-Based Estimation of Myocardial Material Parameters from Cardiac MRI

Yunhe Chen, Xiwen Zhang, Yongzhong Huo, Shuo WangBioengineering 2025

TL;DR

This paper introduces a deep learning approach using ResNet18 to rapidly estimate myocardial material parameters directly from cardiac MRI, significantly reducing the computational burden compared to traditional finite element methods. The model achieves high accuracy on healthy subjects, paving the way for more efficient personalized cardiac modeling.

What Problem Does This Paper Address?

Accurately characterizing the mechanical properties of the heart muscle (myocardial material parameters) is crucial for understanding cardiac function and developing computational models for diagnosis and treatment. Traditional methods for estimating these parameters involve complex, iterative finite element (FE) simulations. This process is computationally expensive and time-consuming, making it impractical for real-time clinical applications. The paper aims to bridge this gap by developing a fast and accurate deep learning alternative.

Methods

The core of this research is a deep learning framework built upon the ResNet18 architecture. The authors modified ResNet18 to accept two-channel input images, representing cardiac magnetic resonance images (CMRI) from end-systole (ES) and end-diastole (ED). The network is trained to directly predict two key myocardial material parameters, denoted as $C_a$ and $C_b$, which are derived from the Holzapfel-Ogden constitutive model.

The process involved:

  1. Generating Ground Truth: A large dataset of 1288 healthy subjects' CMRI data was used to derive reference material parameters ($C_a$ and $C_b$) using traditional inverse finite element (FE) methods. This served as the "ground truth" for training the deep learning model.
  2. Deep Learning Model: A modified ResNet18 was chosen for its balance of accuracy and computational efficiency. The model was trained to map the CMRI image pairs directly to the estimated material parameters.
  3. Hyperparameter Tuning: Extensive tuning was performed for Adam optimizer betas, learning rates, and batch sizes to optimize model performance.
  4. Evaluation Metrics: Performance was assessed using Mean Squared Error (MSE), Mean Absolute Error (MAE), and Mean Relative Error (MRE).

Datasets

  • Training and Validation: A dataset of 1288 high-resolution cine CMRI images from healthy volunteers. These images were processed to generate ground truth material parameters using FE methods.
  • Testing (Healthy Subjects): An independent test set of 194 samples from the same healthy cohort was used for final model evaluation.
  • Testing (Pathological Subjects): The publicly available ACDC dataset was used to evaluate the model's performance on pathological cases, specifically 30 subjects with abnormal right ventricle (ARV) and 30 with hypertrophic cardiomyopathy (HCM).

Key Insights and Ideas

  • Deep Learning as a Viable Alternative: The study strongly demonstrates that deep learning can effectively replace computationally intensive inverse FE methods for estimating myocardial material parameters, offering a significant speedup.
  • ResNet18's Efficiency: ResNet18 proved to be a strong choice, balancing predictive accuracy with significantly lower computational cost and faster training times compared to other architectures like DenseNet121 and Vision Transformers (ViT).
  • Parameter Sensitivity: The study highlights that the model's performance is sensitive to hyperparameter choices, particularly learning rate and batch size, with optimal ranges identified.
  • Heterogeneity in Pathological Tissues: The model's performance degrades on pathological datasets, suggesting that the increased heterogeneity in diseased myocardial tissue poses a significant challenge for current deep learning models trained on healthy data.

Key Results

  • Healthy Subjects Performance: The ResNet18 model achieved high predictive accuracy on healthy subjects, with MAE values around 0.0146 for $C_a$ and 0.0139 for $C_b$. Mean relative errors were below 5%.
  • Speedup: The deep learning approach enables predictions in under one second, a dramatic improvement over the hours typically required by traditional FE methods.
  • Correlation: Strong correlations were found between predicted and FEM-derived parameters ($r \approx 0.9277$ for $C_a$ and $r \approx 0.9258$ for $C_b$).
  • Pathological Subject Performance: Prediction errors were higher for pathological cases (ARV and HCM), with MREs ranging from 11.99% to 23.57%, indicating a decrease in accuracy compared to healthy subjects.

Limitations and Future Work

  • Pathological Data Limitation: The model was trained exclusively on healthy data, which limits its direct applicability to pathological conditions due to increased tissue heterogeneity and remodeling.
  • Future Work:
    • Expand Training Data: Incorporate a more diverse dataset including subjects with various cardiac pathologies to improve generalizability.
  • Data Augmentation/Transfer Learning: Explore these techniques to enhance robustness for pathological cases.
  • 3D Data Integration: Investigate the use of 3D CMRI data for a more comprehensive cardiac structure representation, while addressing computational costs and overfitting.
  • Biomechanical Priors: Integrate physiological constraints to better capture myocardial stiffness and improve $C_b$ estimation.
  • Non-invasive Validation: Utilize techniques like magnetic resonance elastography (MRE) to further validate and refine the model's predictions.

Summary updated