Decision Tree for Key Comparisons

Antonio Possolo, A. Sophia Koepke, David Newton, Michael R. WinchesterJournal of Research of the National Institute of Standards and Technology 2021

This paper, published in the Journal of Research of the National Institute of Standards and Technology, provides a standardized roadmap for one of the most contentious tasks in metrology: aggregating measurement data from different national laboratories.

TL;DR

The authors present a formal "Decision Tree" to guide the selection of statistical models for interlaboratory Key Comparisons (KCs). By using a sequence of statistical tests to account for "dark uncertainty" and non-Gaussian data, the framework replaces ad hoc data reduction with a robust, model-based approach for determining reference values and lab equivalence.

What Problem Does This Paper Address?

In the world of metrology, "Key Comparisons" are the gold standard for ensuring that a kilogram in Paris is the same as a kilogram in Gaithersburg. However, when multiple national metrology institutes (NMIs) measure the same thing, their results rarely align perfectly.

The challenge lies in how to calculate a single consensus value (the Key Comparison Reference Value, or KCRV). Often, the dispersion between labs is much larger than their reported uncertainties—a phenomenon known as "dark uncertainty." Historically, committees have spent significant time debating which labs to exclude as "outliers" or which averaging method to use. This paper seeks to move these decisions from subjective debate to a principled, statistical framework that can handle inconsistent, skewed, or heavy-tailed data without simply discarding valid (if "discrepant") measurements.

Methods

The core contribution is a Decision Tree consisting of four branching nodes (statistical tests) leading to five terminal "leaves" (statistical models).

The Tests: 1. Mutual Consistency: Uses Cochran’s $Q$ test to see if the results are more dispersed than the reported uncertainties suggest. 2. Gaussian Shape: Uses Shapiro-Wilk or Anderson-Darling tests to check for normality. 3. Symmetry: Uses a bootstrap-based test (Miao et al.) to check if the data is balanced around the median.

The Models: * Adaptive Weighted Average: Uses the DerSimonian-Laird procedure to "damp" the influence of labs with unusually small reported uncertainties when dark uncertainty is present. * Weighted Median: A robust estimator used when data is symmetric but non-Gaussian. * Hierarchical Bayesian Models: Three sophisticated models (Gauss+Gauss, Laplace+Gauss, and Skew Student+Gauss) that explicitly model "participant effects" and dark uncertainty using different distributional assumptions (e.g., handling heavy tails or asymmetry).

Datasets

The authors demonstrate the Decision Tree by re-analyzing historical measurement results from several high-profile comparisons:

  • Chemical Metrology: CCQM-K45 (Tin in tomato paste), CCQM-K145 (Zinc and Nickel in bovine liver), CCQM-K88 (Lead in solder), and CCQM-K30.1 (Lead in wine).
  • Radionuclides: Equivalent activity of $^{65}$Zn and the half-life of $^{90}$Sr.
  • Electronics: CCEM.RF-K25.W (Thermistor power sensor efficiency).

No new datasets were introduced, but these diverse real-world examples serve as a benchmark for the tree's versatility.

Key Insights and Ideas

  • Propagating Dark Uncertainty: A major "aha moment" is the insistence that dark uncertainty must be propagated into the final results. Ignoring it leads to "Degrees of Equivalence" (DoEs) that are overconfident, potentially penalizing labs unfairly.
  • Outliers are Technical, Not Just Statistical: The authors argue (Principle P1) that a result should only be excluded for substantive technical reasons (e.g., a known protocol deviation), not just because it sits far from the mean. The hierarchical models are designed to accommodate these "discrepant" results safely.
  • The "Damping" Mechanism: To prevent a single lab with a tiny (and perhaps optimistic) uncertainty from hijacking the consensus value, the models include mechanisms to limit the weight of any single measurement.
  • Consistency is King: The framework ensures that the KCRV and the uncertainties for each lab's degree of equivalence are derived from the same underlying statistical model.

Key Results

  • Improved Robustness: In the CCQM-K145 (Nickel) example, the Decision Tree identified significant dark uncertainty. While the original report used a simple median, the tree’s Hierarchical Gauss+Gauss model provided a more realistic uncertainty estimate that better reflected the actual spread of the data.
  • Handling Asymmetry: For the "Lead in wine" study (CCQM-K30.1), the tree correctly identified significant asymmetry and recommended a Skew Student+Gauss model. This captured the "long tail" of the data far more effectively than standard Gaussian methods.
  • Reproducibility: In the thermistor power sensor case, the Decision Tree managed to reproduce the results of the original expert committee's consensus while following a transparent, repeatable process.

Limitations and Future Work

  • Small Sample Sizes: The authors acknowledge that statistical tests for symmetry and normality have very low power when the number of participating labs is small (e.g., $n < 10$). In these cases, the tree is a guide, but professional scientific judgment remains essential.
  • The "Substantive" Hurdle: The tree only works after humans have decided which data points are technically valid for inclusion. It cannot automate the technical audit of a laboratory's procedures.
  • Software Accessibility: While the paper provides R and Stan code in the appendix, the authors are currently developing a "Shiny App" to make the entire Decision Tree more accessible to metrologists who aren't statistical programming experts.

Summary updated

Abstract

This contribution describes a Decision Tree intended to guide the selection of statistical models and data reduction procedures in key comparisons (KCs). The Decision Tree addresses a specific need of the Inorganic Analysis Working Group (IAWG) of the Consultative Committee (CC) for Amount of Substance, Metrology in Chemistry and Biology (CCQM), of the International Committee for Weights and Measures (CIPM), and it is likely to address similar needs of other working groups and consultative committees. Because the portfolio of KCs previously organized by the CCQM-IAWG affords a full range of opportunities to demonstrate the capabilities of the Decision Tree, the majority of the illustrative examples of application of the Decision Tree are from this working group. However, the Decision Tree is widely applicable in other areas of metrology, as illustrated in examples of application to measurements of radionuclides and of the efficiency of a thermistor power sensor. The Decision Tree is intended for use after choices will have been made about the measurement results that qualify for inclusion in the calculation of the key comparison reference value (KCRV), and about the measurement results for which degrees of equivalence should be produced. Both these choices should be based on substantive considerations, not on purely statistical criteria. However, the Decision Tree does not require that the measurement results selected for either purpose be mutually consistent. The Decision Tree should be used as a guide, not as the sole and autonomous determinant of the model that should be selected for the measurement results obtained in a KC, or of the procedure that should be employed to reduce these results. The scientists running the KCs ultimately have the freedom and responsibility to make the corresponding choices that they deem most appropriate and that best fit the purpose of each KC. The Decision Tree involves three statistical tests, and comprises five terminal leaves, which correspond to as many alternative ways in which the KCRV, its associated uncertainty, and the degrees of equivalence (DoEs) may be computed. This contribution does not purport to suggest that any of the KCRVs, associated uncertainties, or DoEs, presented in previously approved final reports issued by working groups of the CCs should be modified. Neither do the alternative results question existing, demonstrated calibration and measurement capabilities (CMCs), nor do they support any new CMCs.
BibTeX
@article{possolo2021decision,
  author = {Antonio Possolo and A. Sophia Koepke and David Newton and Michael R. Winchester},
  title = {{Decision Tree for Key Comparisons}},
  journal = {Journal of Research of the National Institute of Standards and Technology},
  year = {2021},
  doi = {10.6028/jres.126.007},
}
Figure