NeurIPS 2026Coming to NeurIPS?Explore papers, orals & directions

Data Simulations of a Compressive Sensing Multispectral Imager in the Mid-Infrared Region and Its Performances for the Monitoring of High-Temperature Events

Donatella Guzzi, Massimo Baldi, Tiziano Bianchi, Maria Fabrizia Buongiorno, Cinzia Lastri, Enrico Magli, Vanni Nardino, Lorenzo Palombi, Vito Romaniello, Tiziana Scopa, Mario Siciliani de Cumis, Malvina Silvestri, Diego Valsesia, Valentina Raimondi2023

TL;DR

This paper presents data simulations for a novel mid-infrared (MIR) multispectral imager that uses Compressive Sensing (CS) for high-temperature event (HTE) monitoring. The simulations demonstrate promising Signal-to-Noise Ratio (SNR) and reconstruction quality, suggesting the imager could offer valuable data for applications like fire detection and volcanic activity monitoring.

What Problem Does This Paper Address?

The mid-infrared (MIR) spectral region holds significant potential for Earth Observation (EO) applications, particularly for monitoring high-temperature events (HTEs) like fires, volcanic eruptions, and industrial flaring. However, this spectral region is currently under-exploited. Existing EO systems may lack the necessary spatial resolution or spectral capabilities to effectively capture and analyze these events. This paper addresses this gap by proposing and simulating a new type of imager that leverages Compressive Sensing (CS) to achieve high spatial resolution in the MIR, aiming to improve HTE detection and monitoring.

Methods

The core of the proposed system is a multispectral imager that utilizes Compressive Sensing (CS). CS is a signal processing technique that allows for the reconstruction of a sparse signal from fewer samples than traditionally required. In this imager, a Spatial Light Modulator (SLM) is used to encode the incoming light, and a single-pixel detector captures the modulated signal. Each measurement is a product of the encoded pattern and the image, followed by integration. This approach merges acquisition and compression, potentially leading to more efficient data collection. The paper focuses on simulating the performance of such an imager, specifically evaluating its Signal-to-Noise Ratio (SNR) and the quality of reconstructed images using a CS algorithm.

Datasets

The paper does not use training datasets in the traditional machine learning sense. Instead, it relies on simulated data. For the at-sensor radiance simulations, the authors used the MODTRAN 6 radiative transfer software to generate black body radiance spectra for temperatures ranging from 300 K to 800 K. For testing the CS reconstruction performance, they used a simulated SISSI-like dataset derived from airborne MASTER instrument data acquired over a wildfire in California. This simulated dataset was used to reconstruct images at a compression ratio of 50%.

Key Insights and Ideas

  • MIR's Untapped Potential: The MIR region offers unique advantages for HTE monitoring, but current EO systems haven't fully capitalized on it. This imager aims to bridge that gap.
  • CS for High-Resolution MIR: Compressive Sensing is a powerful tool for achieving high spatial resolution in the MIR, a region where traditional imaging can be challenging and data-intensive.
  • SNR is Key for HTEs: The simulations show that the proposed imager can achieve satisfactory SNR (above 80) for temperatures between 450-800 K, which is crucial for detecting and characterizing HTEs.
  • Reconstruction Quality Matters: Even with a 50% compression ratio, the CS reconstruction algorithm produced temperature fields with a low normalized RMSE (1.5%), indicating that the CS approach can effectively recover important information for HTE analysis.
  • Spectral Bands Tailored for Applications: The selection of spectral bands (3.3, 3.5, 3.7, 3.9, and 4.8 µm) is strategically chosen to address specific HTE-related applications, including the detection of greenhouse gases like CH4 and CO2.

Key Results

  • SNR Performance: The simulated imager is expected to provide satisfactory data quality (SNR > 80) for temperatures in the range of 450–800 K. Data quality is considered acceptable for 400 K, with the exception of the 3.3-µm band. For temperatures below 400 K, the data quality might be insufficient for most applications.
  • Reconstruction Accuracy: When applying a CS algorithm with a 50% compression ratio to a simulated wildfire dataset, the reconstructed temperature fields showed a normalized RMSE of only 1.5% compared to the original simulated data. This indicates a high degree of accuracy in the reconstruction process.
  • Spatial Resolution: The imager is designed for high spatial resolution, with a GSD (Ground Sample Distance) of 15 m at an altitude of 700 km and a super-resolution factor of 4x4.

Limitations and Future Work

  • Detector Noise: The SNR calculations were slightly overestimated because dark current data for the detector were not available. Future work could incorporate this data for a more precise SNR evaluation.
  • Temperature Range: While the imager performs well for higher temperatures, data quality might be insufficient for applications requiring precise measurements below 400 K.
  • Future Applications: The authors highlight the potential of the imager for various HTE-related studies, including fire front analysis, biomass burning gas detection, flaring events, and lava flow monitoring. Further validation with real-world data and more extensive application-specific studies are implied.

Summary updated

BibTeX
@misc{guzzi2023data,
  author = {Donatella Guzzi and Massimo Baldi and Tiziano Bianchi and Maria Fabrizia Buongiorno and Cinzia Lastri and Enrico Magli and Vanni Nardino and Lorenzo Palombi and Vito Romaniello and Tiziana Scopa and Mario Siciliani de Cumis and Malvina Silvestri and Diego Valsesia and Valentina Raimondi},
  title = {{Data Simulations of a Compressive Sensing Multispectral Imager in the Mid-Infrared Region and Its Performances for the Monitoring of High-Temperature Events}},
  year = {2023},
  doi = {10.3390/engproc2023051031},
}
Figure