Data-Driven Modeling of Molten Chloride Corrosion Using Static Test Data

Md Mahmudul Hasan PathikarXiv 2026 · arXiv

TL;DR

Researchers have developed a machine-learning framework to predict corrosion rates in molten chloride salts—a critical challenge for next-generation nuclear reactors and solar power plants. By introducing a novel "Chloride Salt Preparation Index" (CSPI) to standardize how salt purity is reported, the team achieved high predictive accuracy ($R^2$ of 0.85) and provided a reliable way to quantify uncertainty in extreme environments.

What Problem Does This Paper Address?

Molten chloride salts are excellent heat transfer fluids for advanced energy systems, but they are notoriously corrosive. For decades, researchers have conducted experiments to understand how different alloys hold up, yet predicting a corrosion rate across different studies remains a "wild west" scenario.

The challenge is three-fold:

  1. Complexity: Corrosion involves simultaneous electrochemical and thermochemical reactions influenced by temperature, alloy chemistry, and salt impurities.
  2. Data Heterogeneity: Different labs use different salt purification methods, atmosphere controls, and container materials, making apples-to-apples comparisons nearly impossible.
  3. Model Limitations: Traditional physics-based models provide mechanistic insight but often struggle to provide quantitative rate predictions across the broad range of conditions found in the literature.

Methods

The authors built an interpretable machine-learning framework using a blended tree-based ensemble. This ensemble combines four powerful algorithms: XGBoost, CatBoost, Extra Trees (ET), and Gradient Boosting Regressor (GBR).

A standout feature of their methodology is the Chloride Salt Preparation Index (CSPI). Recognizing that a simple "purified vs. unpurified" label is too blunt, the authors created a graded numerical scale (0–1) based on a fixed rubric. This index accounts for the specific purification method (e.g., vacuum drying vs. chemical sparging), atmosphere control, and reported pre-exposure impurities.

To handle the highly skewed nature of corrosion data—where most values are near zero but a few are very high—they applied a logarithmic transformation ($y' = \ln(1 + y)$) to stabilize variance. Finally, they used conformal prediction to generate uncertainty intervals, ensuring the model doesn't just give a "best guess" but also a measure of how confident it is.

The overall machine learning workflow, from data processing to uncertainty quantification.

Datasets

The study compiled a structured dataset of 291 individual static molten chloride corrosion observations extracted from literature published between 1960 and 2024.

The dataset includes 29 numerical variables:

  • 12 Alloy Descriptors: Elemental weight percentages (Fe, Ni, Cr, Mo, etc.).
  • 7 Salt Constituents: Mol% of salts like NaCl, KCl, and MgCl₂.
  • 6 Container Types: Binary indicators for materials like ceramic, graphite, or nickel.
  • 4 Processing Parameters: Temperature, exposure time, CSPI, and the salt volume-to-surface-area ratio (V/SA).
Table 1: Input features and ranges for the chloride-salt dataset (N = 291).

Key Insights and Ideas

  • Salt Purity is the "Hidden" Driver: The CSPI emerged as the most influential variable in the model. The authors found that a graded index retains significantly more useful information than a binary classification, effectively capturing the "experimental context" that usually acts as noise in large datasets.
  • Interpretability Matches Intuition: Using SHAP (Shapley Additive Explanations) analysis, the model's "logic" was shown to align with established materials science. For example, higher Molybdenum (Mo) content decreased predicted corrosion, while higher Chromium (Cr) content increased it—consistent with the known preferential dissolution of Cr in chloride melts.
  • The V/SA Factor: Adding the salt volume-to-surface-area ratio (V/SA) improved the model's performance ($R^2$ increased from 0.81 to 0.85). This highlights that the "geometry" of a static test matters; a small volume of salt can become saturated with corrosion products, artificially slowing down the measured rate.
  • Uncertainty is Calibrated: The conformal prediction intervals were well-calibrated, meaning the 90% confidence intervals actually contained the true value about 90% of the time. This is vital for engineering applications where underestimating corrosion could lead to catastrophic failure.

Key Results

The blended ensemble outperformed individual learners and traditional regression models.

  • Accuracy: The model achieved a cross-validated $R^2$ of 0.85 and a Mean Absolute Error (MAE) of 0.41 mg cm⁻² day⁻¹.
  • Feature Importance: CSPI, exposure time, and temperature were the top three predictors.
  • Data Transformation: The log transformation successfully reduced target skewness from 6.07 to 1.80, allowing the regression algorithms to penalize relative errors more effectively.
Figure 2: Distributions of corrosion rates (a) before and (b) after log transformation.

Limitations and Future Work

The authors are transparent about the limitations of using historical data:

  • Static vs. Dynamic: The model is based on static tests, which cannot capture the effects of flowing salt, thermal gradients, or mass transport found in real-world reactors.
  • Reporting Gaps: Many studies omit critical parameters like in-situ redox potential or detailed alloy microstructure. The authors argue that more consistent reporting of these "contextual" variables is more important for future models than simply collecting more data points.
  • Future Directions: The next step is to evolve this framework to incorporate flow velocity and mechanical loading, bridging the gap between laboratory static tests and service-relevant environments.

Summary updated

Abstract

Molten chloride corrosion has been studied for decades, yet reliable prediction across different alloys, salts, and test conditions remains difficult. In this work, 291 static molten chloride corrosion experiments reported in the literature were compiled into a structured dataset and used to develop an interpretable machine-learning framework for corrosion-rate predictions. To better represent the differences in salt condition across studies, a Chloride Salt Preparation Index (CSPI) was introduced to bring the reported salt-treatment method, atmosphere control, and pre-exposure impurity condition on a common numerical scale. A blended tree-based ensemble provided the most consistent predictive performance, achieving a cross-validated \(R^2\) of 0.85 and an MAE of 0.41 mg cm\(^{-2}\) day\(^{-1}\). The graded CSPI retained more useful information than a simple purified/unpurified classification and emerged as the dominant model descriptor. Global sensitivity and SHAP analyses further identified exposure time, temperature, and alloy chemistry as important contributors to the model predictions, with several observed trends consistent with the established molten-chloride corrosion behavior. The conformal prediction intervals were well calibrated, providing an estimate of prediction uncertainty in addition to the point prediction. Overall, the framework demonstrates that historical corrosion data can support quantitative, interpretable, and uncertainty-aware prediction when experimental context is represented explicitly, while also highlighting where more consistent reporting and targeted experiments are needed to improve future molten-salt corrosion models.
BibTeX
@misc{pathik2026data,
  author = {Md Mahmudul Hasan Pathik},
  title = {{Data-Driven Modeling of Molten Chloride Corrosion Using Static Test Data}},
  year = {2026},
  eprint = {2611.07125},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.07125},
}
Figure