Data-based Distributionally Robust Stochastic Optimal Power Flow, Part II: Case studies

Yi Guo, Kyri Baker, Emiliano Dall'Anese, Zechun Hu, Tyler H. SummersarXiv 2018 · arXiv · OpenReview

TL;DR

This paper presents a data-driven approach to robustly manage power grids under uncertainty, specifically addressing overvoltages in distribution networks and line flow risks in transmission networks. By directly learning from forecast error data, their method offers a flexible way for grid operators to balance operational costs, constraint violation risks, and performance reliability.

What Problem Does This Paper Address?

Modern power grids are increasingly incorporating renewable energy sources like solar and wind, which introduce significant uncertainty due to their intermittent nature and forecasting errors. This variability poses challenges for grid stability and reliability, leading to issues like overvoltages in distribution networks and potential overloads on transmission lines, especially under N-1 contingency scenarios (where a single component fails). Traditional methods often rely on strong assumptions about the distribution of these forecast errors, which may not hold in practice. This paper tackles the problem of making optimal operational decisions in power grids while explicitly accounting for the uncertainty in renewable energy forecasts and the inherent sampling errors in the data used to model these uncertainties.

Methods

The core of this paper is the application and validation of a "data-based distributionally robust stochastic optimal power flow (OPF)" methodology, building upon the theoretical framework presented in Part I of their work. Key techniques include:

  • Distributionally Robust Optimization (DRO): Instead of assuming a specific probability distribution for forecast errors, DRO considers a "ball" of possible distributions around the empirical data. This makes the solution robust to deviations from the assumed distribution.
  • Wasserstein Distance: This metric is used to define the "ball" of distributions, allowing for a quantifiable measure of robustness to sampling errors.
  • Model Predictive Control (MPC): The OPF problem is solved iteratively over a planning horizon. At each step, the system predicts future states and optimizes control actions, then updates based on new measurements. This allows for dynamic adjustments to grid operations.
  • Data-Driven Approach: The method directly uses historical forecast error data for training. This data can be updated online, allowing the system to adapt to changing conditions.
  • Balancing Trade-offs: The methodology explicitly incorporates tunable parameters (p and ε) that allow grid operators to systematically balance competing objectives: operational costs, the risk of violating voltage or line flow constraints (quantified using Conditional Value-at-Risk or CVaR), and robustness to forecast errors.

Datasets

  • Distribution Network: The paper uses a modified IEEE 37-node test feeder. Load data is derived from real measurements. Photovoltaic (PV) systems are integrated, and their forecast errors are generated using a greedy gradient boosting method based on historical irradiation data.
  • Transmission Network: A modified IEEE 118-bus test system is used. Wind power forecast errors are derived from real wind sampling data from the Global Energy Forecasting competition (GEFCCom2012), which are noted to be leptokurtic (heavy-tailed).

Key Insights and Ideas

  • Directly Learning from Errors is Powerful: By using forecast error data directly, the method avoids potentially inaccurate assumptions about error distributions, leading to more reliable solutions, especially for non-Gaussian errors.
  • Tunable Robustness: The parameters p (risk aversion) and ɛ (Wasserstein radius) provide a crucial knob for grid operators to explicitly control the trade-off between economic efficiency and operational security. Increasing p or ɛ leads to more conservative (and thus safer, but potentially more expensive) operation.
  • Systematic Management of Overvoltages: In distribution networks, the method effectively uses local energy storage and PV curtailment to mitigate overvoltages caused by high PV penetration.
  • Proactive N-1 Security in Transmission: For transmission networks, the approach proactively manages reserve policies for generators to prevent line flow constraint violations under potential N-1 contingencies, especially with high wind penetration.
  • Out-of-Sample Performance Matters: The MPC framework, combined with DRO, demonstrates good out-of-sample performance, meaning the decisions made are robust even when faced with unseen forecast error realizations.

Key Results

  • Distribution Network: The data-based DRO-MPC successfully mitigated overvoltages by adjusting PV curtailment and energy storage setpoints. Figures show that increasing the risk aversion parameters (p and ɛ) leads to reduced operational costs and lower CVaR of voltage constraint violations.
  • Transmission Network: The method effectively managed N-1 security constraints for line flows. Figures illustrate that increasing p and ɛ leads to a decrease in the CVaR of line flow constraint violations, albeit at the cost of increased operational expenses. For example, in Figure 8(a), increasing p leads to a decrease in CVaR, while operational cost increases.
  • Computational Performance: The optimization problems were solved within reasonable timeframes (e.g., 4.84 seconds per time step for the distribution case, 10 seconds for the transmission case on a standard laptop), indicating scalability for practical applications.

Limitations and Future Work

  • Battery Efficiency and Life: The paper acknowledges that for simplicity, battery charging/discharging efficiencies were approximated as 1, and battery degradation was not explicitly modeled. Extending the formulation to include these factors would increase complexity but is a promising avenue for future research.
  • Voltage at Slack Bus: Similar to much of the literature, the voltage at the slack bus is treated as an input and not a controllable variable. Incorporating discrete variables for transformer tap position control could be a future extension.
  • Line Outage Complexity: While the paper focuses on line outages for N-1 security, it notes that a single line outage could potentially cause multiple generator/load failures, which adds complexity to the modeling.
  • Generalization of DRO: The paper mentions that while DRO was applied to voltage and line flow constraints, other constraints could also be handled in a distributionally robust manner.
  • Computational Speed: While the current computational times are acceptable, further optimization for speed and scalability to larger systems is suggested.

Summary updated

Abstract

This is the second part of a two-part paper on data-based distributionally robust stochastic optimal power flow (OPF). The general problem formulation and methodology have been presented in Part I [1]. Here, we present extensive numerical experiments in both distribution and transmission networks to illustrate the effectiveness and flexibility of the proposed methodology for balancing efficiency, constraint violation risk, and out-of-sample performance. On the distribution side, the method mitigates overvoltages due to high photovoltaic penetration using local energy storage devices. On the transmission side, the method reduces N-1 security line flow constraint risks due to high wind penetration using reserve policies for controllable generators. In both cases, the data-based distributionally robust model predictive control (MPC) algorithm explicitly utilizes forecast error training datasets, which can be updated online. The numerical results illustrate inherent tradeoffs between the operational costs, risks of constraints violations, and out-of-sample performance, offering systematic techniques for system operators to balance these objectives.
BibTeX
@misc{guo2018data,
  author = {Yi Guo and Kyri Baker and Emiliano Dall'Anese and Zechun Hu and Tyler H. Summers},
  title = {{Data-based Distributionally Robust Stochastic Optimal Power Flow, Part II: Case studies}},
  year = {2018},
  eprint = {1804.06384},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/1804.06384},
}
Figure