CycleSpectra: Cyclic Motion Spectra for Phase-Queryable 4D Cardiac Reconstruction

Xueming Fu, Xin Li, Lixia Han, Ao Shen, Guangming Lu, Song Luo, S Kevin ZhouNeurIPS 2026

TL;DR

To measure how well a heart is pumping, doctors often need a full 3D video of its beat, reconstructed from just two snapshot scans. Most AI models try to connect the dots between these snapshots as a straight or piecewise path, forgetting a basic biological truth: a heartbeat is a closed, repeating loop. CycleSpectra bakes periodicity directly into the math by predicting Fourier waves for every point in the heart, allowing you to query the exact 3D shape at any moment in the cycle—even when your input snapshots aren't captured at peak contraction or relaxation.

What Problem Does This Paper Address?

Dynamic cardiac assessment—measuring vital signs like left-ventricular ejection fraction (LVEF, the percentage of blood pumped out per beat)—relies on tracking how heart tissue moves over time (4D reconstruction). Because taking continuous, high-resolution 3D scans exposes patients to radiation or long scan times, we want to reconstruct the entire cardiac cycle from sparse observations, ideally just two 3D frames.

Existing deep learning approaches—whether aligning pairs of images or feeding a timestamp $t$ into a neural network—treat the heartbeat as a discrete sequence of frames or an open-ended trajectory. They expect the network to learn that the heart eventually returns to where it started. Furthermore, standard MRI benchmarks use thick 5–10 mm slices (which blur motion and inflate image-quality scores) and almost always hand the model the two most convenient anchor points: peak relaxation (end-diastole, ED) and peak contraction (end-systole, ES). If a clinical scan gives you two arbitrary frames from the middle of a beat, traditional interpolation methods lose the plot.

Figure 1: Left: thick cine slabs inflate image scores and hide true motion. Right: real voxel trajecto- ries (green) are non-monotonic, but prior work only learns piecewise paths between anchors (blue).

Methods

Instead of asking a neural network to learn periodicity from scratch, CycleSpectra makes cyclic structure the mathematical foundation of its motion representation.

Given two 3D cardiac volumes from opposite halves of the heartbeat (an "anchor" frame and a "context" frame), the pipeline works in four steps:

  1. Shared Feature Extraction: A standard 3D convolutional encoder extracts multi-scale anatomical features from both input volumes.
  2. DualMotion Encoder: Compares the two volumes to output where the motion happens (a dense spatial context map) and how the overall cycle behaves (a global latent code split into $K$ frequency tokens).
  3. Spectral Motion Decoder (The Core Novelty): Rather than taking time as a network input, the decoder predicts $K$ pairs of sine and cosine Fourier coefficient maps in a low-dimensional latent space (default $K=4$). To find out how the heart deforms at any query phase $\psi_q \in [0, 1)$, the model simply plugs $\psi_q$ into a parameter-free, closed-form inverse Fourier series equation. Continuity and periodicity are guaranteed by trigonometry.
  4. Flow Refinement & Endpoint Closure: Two lightweight convolutional blocks upsample the coarse latent flow to full image resolution, warps the anchor scan to synthesize the target frame, and enforces an endpoint-closure loss during training—making sure a predicted mid-cycle frame can warp right back to the held-out input frame.
Figure 2: CycleSpectra overview. A shared encoder extracts anatomy features from anchor and context volumes; the DualMotion Encoder (b) produces a spatial deformation context and a global cycle code; the phase-queryable decoder (c) predicts Fourier coefficient maps in the latent feature space and analytically synthesizes a coarse flow; two refinement blocks recover the image-scale field.

Datasets

  • In-house 4D Cardiac CT Cohort (New): 36 subjects (split 22 train / 7 validation / 7 test) scanned at thin-slice 1.6 mm resolution with 6–24 phases per heartbeat. Unlike thick-slice MRI benchmarks like ACDC, this preserves crisp 3D anatomy. The authors test two setups on the 7 held-out patients: the standard Canonical ED/ES pair (7 pairs) and a much tougher Opposite-pair protocol using 85 arbitrary systolic/diastolic frame pairs.
  • Out-of-Distribution Cohorts: Evaluated zero-shot (without retraining) on an external 4D-CT cohort and a cross-modality 4D cardiac MRI (4D-cMR) dataset, alongside multi-frame fusion tests.

Key Insights and Ideas

  • Feeding sine waves into a network $\neq$ outputting a sine wave: In a clever ablation, the authors replaced their analytic Fourier readout with a standard flow decoder conditioned on sinusoidal time embeddings (like Transformer positional encodings). Image sharpness stayed almost identical, but LVEF error more than doubled (from 8.00% to 19.69%). Giving a network periodic inputs doesn't force it to learn a periodic trajectory.
  • Heartbeats are surprisingly low-frequency: Varying the number of Fourier harmonics $K$ from 1 to 6 barely changed motion accuracy—even $K=1$ or $2$ captured the bulk of ventricular contraction and relaxation.
  • High PSNR can be an illusion: Because most of a chest CT volume is static ribs and lungs, naive baselines that barely move the heart still score great on full-volume PSNR while completely failing clinical metrics like ventricular volume curves.
  • Two frames work at test time because of dense supervision at train time: Two snapshots obviously can't uniquely define a multi-harmonic wave on their own. CycleSpectra succeeds because training sweeps across all available phases per patient, teaching the network a population-level prior of how human hearts move; the two test frames just anchor where the patient sits on that curve.

Key Results

Under the challenging non-canonical opposite-pair protocol (where inputs aren't neatly aligned to ED/ES):

  • Clinical Motion Fidelity: CycleSpectra achieves the lowest nominal mean LVEF error at 8.00% (compared to 24.41% for UVI-Net, 24.47% for TMKD, and 9.41% for FusionNet) and the highest ventricular volume–time curve correlation at 0.862.
  • Anatomical Overlap: Reaches a chamber Dice score of 0.821 (statistically outperforming every baseline on paired subject bootstrap intervals) and a 95% Hausdorff distance (HD95) of 7.94 mm, with virtually zero tissue folding (0.009% folded voxels).
  • Canonical ED/ES: Remains competitive (0.800 Dice, 7.80% LVEF error), though specialized interpolation baselines like FusionNet slightly edge it out on curve correlation (0.781 vs. 0.632) when handed exact extrema.

Limitations and Future Work

  • Small Cohort & Pathology Gaps: With only 36 total patients and 7 test subjects, statistical confidence intervals overlap with top baselines like FusionNet on some functional metrics. Furthermore, the lone test patient with severely reduced heart function (ground-truth LVEF 32.3%) caused a clear failure (22.4% LVEF error), and raw CT scans cannot be publicly shared.
  • Arrhythmias Break Periodicity: By assuming a single, closed periodic loop, the math naturally struggles if a patient has an irregular heartbeat (arrhythmia).
  • Dense Training Requirement: While test-time inference only needs two frames, ablations show that training on sparse frames (only 3 phases per patient) drops curve correlation from 0.862 to 0.432.
  • Evaluation Scope: The deterministic model provides no uncertainty estimates, and fine-grained local myocardial strain remains unvalidated due to the lack of tagged MRI ground truth. Future extensions can leverage its built-in support for test-time multi-frame latent fusion when more than two scans are available.

Summary updated

Abstract

Reconstructing patient-specific cyclic cardiac motion at arbitrary phases is central to dynamic cardiac assessment, underpinning measurements such as ejection fraction, stroke volume, and regional myocardial deformation. Existing methods—pair-wise registration, time-conditioned decoders, and coordinate-based implicit fields—share a common implicit assumption: the cardiac cycle is treated as a sequence of discrete phases, with temporal structure assembled through learned mappings supervised at the observed frames. Yet the cycle is a closed periodic process. We propose CycleSpectra, a spectral motion representation that takes the cyclic structure as a starting point of the representation rather than as a property to be learned. Given a pair of sparsely sampled phase observations, the model learns the spectral structure of the underlying cyclic cardiac motion in a low-dimensional latent space, and recovers the displacement at any phase through a fixed analytic synthesis layer—time never enters the network as a learnable signal, only as a coordinate the readout takes by construction. To support evaluation, we collect a thin-slice phase-resolved 4D cardiac CT cohort and benchmark under both canonical and non-canonical input protocols, reporting whole-cycle motion-fidelity metrics alongside standard image and anatomical metrics. Under arbitrary two-frame input, CycleSpectra attains the lowest mean left-ventricular ejection-fraction error and the highest mean ventricular volume–time curve correlation among recent baselines, while remaining competitive on image fidelity. Beyond two-frame inference, the proposed framework supports test-time multi-frame latent fusion for higher accuracy, validated on both the in-house cohort and a cross-modality 4D cardiac MR cohort. Code is available at https://github.com/windrise/CycleSpectra.
BibTeX
@inproceedings{fu2026cyclespectra,
  author = {Xueming Fu and Xin Li and Lixia Han and Ao Shen and Guangming Lu and Song Luo and S Kevin Zhou},
  title = {{CycleSpectra: Cyclic Motion Spectra for Phase-Queryable 4D Cardiac Reconstruction}},
  booktitle = {Advances in Neural Information Processing Systems},
  year = {2026},
  url = {https://openreview.net/forum?id=R6WdWujy5S},
}
Figure