CURRENT: A Recurrent Neural Network for Concurrent Spatial and Temporal Super-Resolution of 4D Flow MRI

Luuk Jacobs, Pietro Dirix, Sebastian KozerkearXiv 2026 · arXiv

TL;DR

CURRENT is a unified recurrent neural network (RNN) designed to perform simultaneous spatial and temporal super-resolution (SR) for 4D Flow MRI. By leveraging bidirectional recurrent connections to exploit temporal redundancies, CURRENT outperforms existing sequential pipelines and provides more accurate downstream hemodynamic measurements, such as relative pressure estimation.

What Problem Does This Paper Address?

4D Flow MRI is a powerful tool for non-invasively quantifying blood flow in three dimensions over the cardiac cycle. However, it suffers from a fundamental trade-off: achieving high spatial and temporal resolution requires prohibitively long scan times. While deep learning (DL) has been used for post-acquisition super-resolution to "enhance" lower-resolution scans, most existing methods focus on either the spatial or temporal dimension in isolation.

This "one-at-a-time" approach is problematic. Hemodynamic analysis—like calculating the relative pressure across a heart valve—relies on derivatives in both space and time. If you perform spatial SR and temporal SR sequentially, you may fail to capture the intrinsic correlations between how blood moves across voxels and how it evolves over heartbeats. The authors sought a unified framework that could handle both tasks simultaneously.

Methods

The authors propose CURRENT, a Recurrent Neural Network architecture. Unlike standard convolutional networks (CNNs) that treat each cardiac frame as an independent image, CURRENT uses Bidirectional Convolutional Recurrent Neural Network (BCRNN) layers. This allows the model to "see" information from both preceding and subsequent cardiac bins when reconstructing any given frame.

Key architectural features include:

  • Shared Encoding/Separated Decoding: The network uses a single path to encode features efficiently but employs three distinct output paths to predict the three velocity components ($v_x, v_y, v_z$).
  • Learnable Skip Connections: Instead of standard additive skip connections, CURRENT uses learnable scaling factors ($\rho$) to optimize gradient flow during training.
  • Flexible Upsampling: A central upsampling layer allows the network to be configured for spatial-only, temporal-only, or joint spatiotemporal SR.
Figure 2: Overview of CURRENT architecture. A) The network receives a temporal window of cubic patches (dashed black box) as input and incorporates BCRNN layers (passing hidden states between preceding [backward pass] and subsequent [forward pass] cardiac bins) and learnable short/long skip connections surrounding a central bicubic upsampling. B) The optimized scaling factors for the short (𝜌𝑛 for

Datasets

Training deep learning models for MRI is challenging because "ground truth" high-resolution (HR) in vivo data is nearly impossible to acquire. To solve this, the authors used:

  • Synthetic Data (RACLETTE): They generated 25 aortic geometries and performed high-fidelity Computational Fluid Dynamics (CFD) simulations. These "perfect" flow fields were then embedded into real in vivo thoracic MRI backgrounds to simulate realistic noise and artifacts.
  • In Vivo Validation: To test generalization, the model (trained only on synthetic data) was applied to a 4D flow scan of a healthy 26-year-old volunteer.

Key Insights and Ideas

  • Temporal Context Matters for Spatial SR: One of the most significant findings was that CURRENT outperformed dedicated spatial-only models (like S4DFlowNet). This suggests that the network uses the "motion" information from neighboring frames to better resolve spatial details in the current frame.
  • The "Joint" Advantage: For spatiotemporal SR, CURRENT outperformed two-stage approaches (e.g., doing spatial SR then temporal SR). This confirms that a unified model better preserves the complex physics of fluid flow.
  • Beyond Pixel Accuracy: The paper emphasizes clinical utility. They evaluated the models using vWERP (virtual Work-Energy Relative Pressure), showing that joint SR leads to much more reliable pressure estimates, which are critical for assessing conditions like aortic stenosis.
Comparison of joint SR vs. sequential stages for relative pressure estimation.

Key Results

  • Superior Spatial Performance: In synthetic tests, CURRENT achieved a lower mean directional error (DE: 0.072 vs 0.097) and lower normalized root-mean-square error (nRMSE: 0.189 vs 0.213) compared to S4DFlowNet.
  • Pressure Estimation Accuracy: Joint spatiotemporal SR using CURRENT yielded a high correlation ($R^2 = 0.973$) and lower bias ($-0.057$ mmHg) for relative pressure estimation compared to spatial-only or temporal-only methods.
  • Generalization: Qualitatively, CURRENT successfully denoised and resolved flow in narrow supra-aortic branches in real human data, demonstrating that the synthetic training strategy translates well to the clinic.
Figure 3: Qualitative comparison of classical upsampling (sinc and linear) and DL-based SR methods. Velocity magnitudes during peak systole (top rows) and their differences with HR (bottom rows) are shown for a) spatial b) temporal and c) spatiotemporal SR. The dashed green lines in the sagittal (x-y) and temporal (x-t) slices indicate the spatial column and peak systolic frame used for the x-t and x- y slices, respectively.

Limitations and Future Work

While promising, the authors note several areas for improvement:

  • Physics Constraints: The current model is purely data-driven. Future versions could incorporate "physics-informed" losses (like a divergence-free condition) to ensure the predicted flow strictly obeys the laws of fluid mechanics.
  • Real-world Artifacts: Synthetic data doesn't capture every MRI imperfection, such as eddy currents or complex patient motion (respiratory jitters).
  • Integration: Currently, SR is a post-processing step. Integrating this network directly into the MRI reconstruction pipeline could potentially offer even greater gains in speed and quality.

Summary updated

Abstract

Objective: To improve the spatial and temporal resolution of aortic 4D flow MRI through a unified deep learning framework for post-acquisition super-resolution (SR) of reconstructed velocity vector fields. Methods: We propose CURRENT, a recurrent neural network that performs spatial and temporal SR with a single network architecture. Supervised training was conducted using paired low- and high-resolution datasets generated by embedding computational fluid dynamics simulations of aortic flow into in vivo thoracic MRI backgrounds, followed by controlled spatial and temporal downsampling. CURRENT was evaluated for two-fold spatial and temporal SR against 4DFlowNet and for two-fold spatiotemporal SR against sequential spatial and temporal SR pipelines based on 4DFlowNet. Image-based and k-space-based quantitative metrics were considered and conventional interpolation were used as baselines. In addition, the impact of CURRENT's spatiotemporal SR on physics-informed relative pressure estimation was assessed. Finally, the ability of CURRENT to generalize from synthetic training data to in vivo acquisitions was investigated. Results: CURRENT achieved superior spatial SR performance and comparable temporal SR performance to dedicated 4DFlowNet models while providing a unified solution for both tasks. Simultaneous spatiotemporal SR using CURRENT yielded more accurate relative pressure estimates than either spatial or temporal SR alone and outperformed sequential 4DFlowNet-based spatial and temporal SR approaches. Furthermore, the proposed model demonstrated promising generalization to in vivo 4D flow MRI data despite being trained exclusively on synthetic datasets. Conclusion: CURRENT provides a unified framework for spatial and temporal SR of 4D flow MRI. The proposed approach has the potential to enhance physics-based analysis and broaden the applicability of accelerated 4D flow MRI.
BibTeX
@misc{jacobs2026current,
  author = {Luuk Jacobs and Pietro Dirix and Sebastian Kozerke},
  title = {{CURRENT: A Recurrent Neural Network for Concurrent Spatial and Temporal Super-Resolution of 4D Flow MRI}},
  year = {2026},
  eprint = {2611.14058},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.14058},
}
Figure