Dissolution in vitro of valaciclovir hydrochloride sustained release tablets (VACV-SRT) was tested by the first method of dissolution according to ChP 2000. A same single oral dose of VACV-SRT or VACV common tablets was given to 6 dogs in randomized crossover study. Plasma levels were determined by HPLC and absorption fractions were calculated according to Wagner-Nelson's formula and deconvolution technique. The results showed that VACV-SRT had a satisfactory correlation between dissolution in vitro and absorption in vivo .